Manuel d'utilisation / d'entretien du produit 116B du fabricant Bryant
Aller à la page of 22
1 16B Legacy t Line 16 Air C onditioner with Puron r Refrigeran t 1 - - 1/2 to 5 Nominal T ons Pr oduct Data the environmentally sound refrigerant Brya nt ’ s Air Condit i oner s wi t h Puron r re f r ige r a nt pr ovi de a collectio n o f features un match ed b y any oth er family of equ ip men t.
2 MODEL NUMBER NOMENCLA TURE 1 2 34 5 6 7 8 9 1 0 1 11 2 1 4 N N N A A/N N N N N A/N A/N N A 1 1 6B N A 0 3 60 0 0 0 Prod- uct Fam il y Tier SEER Major Serie s Vo l t a g e Gr ille Va r i a t i o n s .
3 REFRIGERANT PIP ING LENGTH LIMI T A TIONS Liquid Line Sizing and Maximum T otal Equival e nt Le ngths { for Coo ling O n ly Sy stems with P uron r Refrig era nt : The ma xim um all owa bl e le ngt h.
4 REFRIGERANT CHARGE ADJUSTMENTS Liquid Line S ize Puron Charge oz /ft 3/8 0.60 (F actory charg e for lineset = 9 oz) 5/16 0.40 1/4 0.27 Unit s a re fac t or y cha r ged f or 15 f t ( 4.6 m) of 3/8” liqui d li ne . The fa c t ory c ha r ge for 3/8” li ne se t 9 oz.
5 ACCESSO R Y THERMOS T A TS PA R T N U M B E R PRO GR AM GAS ELECTRIC HEA T COOL T 2 --- P A C 0 1 5 --- 2 D a y √ √ 1 1 T 2 --- N A C 0 1 NP √ √ 1 1 T2SNA C0 1 NP √ √ 1 1 THER MOS T AT A.
6 ACCESSO R Y USAGE GUIDELI NE ACCESSORY RE QUIRE D FOR LOW - - - AMBI - ENT COOLING APPLIC ATIONS (Below 55 ° F/12. 8 _ C) RE QUIRE D FOR LONG LINE APPLICATIONS* (Ov er 80 ft ./ 24. 38 m) REQUI RED FOR SEA COA ST APPLICATIONS ( W i t h i n2m i l e s / 3 .
7 Ac ce ss or y De sc r iptio n and Us age (List ed A lphabe tic ally ) ( Co ntinue d) 10. Sound Hood W r apa r ound s ound re duc i ng cove r for the c ompr es s or . Re duc e s the sound le ve l by a bout 2 dBA. Us age G uide l ine : Sugges t e d whe n unit is ins t a ll e d cl os e r t ha n 15 ft ( 4.
8 ELECTRICAL DA T A UNIT S IZE V/PH OPER VOL TS* COMP R FA N MCA MIN WIR E SIZE { 60 ° C MIN WIR E SIZE { 75 ° C MAX LENG TH ft. (m) } 60 ° C MAX LENG TH ft. (m) } 75 ° C MAX FUSE ** or CKT B RK AMPS MAX MIN LRA RLA FLA 018 - - - B 208/230/1 - - - 60 253 197 48.
9 DIMENSIONS - - ENGLISH B 3" K 5/16" L C 3 1/2" 1 7/8" N P M E F G A 208-230-1-60 230-1-60 208/230-3-60 460-3-60 UNIT SERIES ELECTRICAL CHARACTERISTICS AB C D EF G K L M NP OPERAT.
10 DIMENSIONS - - SI B C 88.9 47.6 P A 76.2 K 8.0 L N M E F G 208-230-1-60 230-1-60 208/230-3-60 460-3-60 UNIT SERIES ELECTRICAL CHARACTERISTICS AB C D EF G K L M N P OPERATING WEIGHT (Kgs) SHIPPING WEIGHT (Kgs) SHIPPING DIMENSIONS (L x W x H) 116BNA018 A X O O O 587.
11 CLEARANCES Clearances (various examples) W all 6” (152.4) 24” (609.6) Service W all W all W all 12” (304.8) 12” (304.8) 18” (457.2) 24” (609.6) Service 6” (152.4) 12” (304.8) 24” (609.6) Service 24” (609.6) Service 24” (609.6) Service Note: Numbers in ( ) = mm 18” (457.
12 TESTED AHRI COMBINA TION RA TINGS* NOTE: Ratings contained in th is documen t are subject to change at any time. For AHRI ratings certificates, please r efer to the AHRI dir ectory www .ahridirectory .org Additional rati ngs and system combinations can be accessed via the Bryant database at: http://cacta xcredits.
13 DET AILED COOLING CAP ACITIES # EVAPORA TOR AIR CO ND ENS ER ENT ERI N G AI R TEM PER ATURES ° F (° C ) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.
14 DET AILED COOLING CAP ACITIES # (CONT .) EVAPORA TOR AIR CO ND ENS ER ENT ERI N G AI R TEM PER ATURES ° F (° C ) 75 (23.9) 85 (29.4) 95 (35) 105 (40.
15 DET AILED COOLING CAP ACITIES # (CONT .) EVAPORA TOR AIR CO ND ENS ER ENT ERI N G AI R TEM PER ATURES ° F (° C ) 75 (23.9) 85 (29.4) 95 (35) 105 (40.
16 DET AILED COOLING CAP ACITIES # (CONT .) EVAPORA TOR AIR CO ND ENS ER ENT ERI N G AI R TEM PER ATURES ° F (° C ) 75 (23.9) 85 (29.4) 95 (35) 105 (40.
17 DET AILED COOLING CAP ACITIES # (CONT .) EVAPORA TOR AIR CO ND ENS ER ENT ERI N G AI R TEM PER ATURES ° F (° C ) 75 (23.9) 85 (29.4) 95 (35) 105 (40.
18 CONDENSER ONL Y RA TI NGS SST °F ( °C ) CONDENS ER ENTERING AIR TEMPERAT URES ° F (° C) 55 (12.78) 65 (18.33) 75 ( 23.89) 85 ( 29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51. 67) 116BNA018 ****B 30 ( - - - 1. 11) TCG 15.70 14.90 14.10 13.20 12.
19 CONDENSER ONL Y RA TI NGS CONTINUED SST °F ( °C ) CONDENS ER ENTERING AIR TEMPERAT URES ° F (° C) 55 (12.78) 65 (18.33) 75 ( 23.89) 85 ( 29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51. 67) 116BNA036 ****A 30 ( - - - 1. 11) TCG 31.50 29.90 28.
20 CONDENSER ONL Y RA TI NGS CONTINUED SST °F ( °C ) CONDENS ER ENTERING AIR TEMPERAT URES ° F (° C) 55 (12.78) 65 (18.33) 75 ( 23.89) 85 ( 29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51. 67) 116BNA049 ****A 30 ( - - - 1. 11) TCG 45.00 42.40 39.
21 GUI D E SPEC I FIC A TI ON S GENERAL Sy stem D escriptio n Outdoor- - mount ed, a i r- - coole d, spl i t- - sys t e m ai r cond it i one r unit sui t a ble f or gr ound or rooft op ins t al l a ti on. Uni t cons i s ts of a her me tic com pre s s or , a n ai r- - cool e d coi l , pr opel l e r- - type conde ns e r fa n, a nd a cont rol box.
22 SYSTE M DE SIGN SU MMA R Y 1. Int e nde d for outdoor i ns ta l l at i on wi th f r e e a i r inl e t a nd out l et . Out door f a n e xte r na l s t a ti c pr es s ur e a va i la bl e is les s t han 0.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Bryant 116B c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Bryant 116B - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Bryant 116B, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Bryant 116B va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Bryant 116B, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Bryant 116B.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Bryant 116B. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Bryant 116B ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.