Manuel d'utilisation / d'entretien du produit U130T*FRN du fabricant Bradford-White Corp
Aller à la page of 28
(To be performed ONLY by qualified service providers) Save this manual for f utu re r eference Manual 47132A The Bradford White R U150L*FRN U1504S*FRN U430T*FRN U440T*FRN U4403S*FRN U4503*FRN U1XR403S*FRN ( *) Denotes Warranty Years.
The Bradford White Ultra Low NOx Gas Water Heaters Page Service Procedure Introduction 3 - - - Gas Control Troubleshooting Chart 5 - - - Tools Required for Service 4 - - - Burner and Inner Door Gasket.
The Bradford White ECO-DEFENDER Safety System The Bradford White ECO-DEFENDER Safety System was designed to resist the ignition of flammable vapors that can occur outside of the water heater.
It is intended for this manual to be used by qualified service personal for the primary purpose of troubleshooting and repair of the Bradford White ECO-DEFENDER Series of water heaters. The Honeywell WV8860Q Gas Control will display error codes in the event of ab normal operation.
Page 5 LED Sta t us Cont r ol St at us Pr obabl e Cause Servi ce Procedu re N on e (LED n ot on or f l ash in g) G a s v al v e is oper at i n g n orm al l y . Pilot fl am e m ay n ot be pres en t . C h eck f or pil ot f lam e t h r ou gh sigh t gl ass an d l ig h t if n ec e s s ar y .
Page 6 LED Sta t us Contr ol St at us Probabl e Cause Ser v i ce Pr oce dur e Fi v e f l ash es an d t h ree secon d pau se. Th e r mo s ta t we ll fa ult. 1. Dam age t o t h e the rm o we ll wi r e . 2. T h erm ow el l sen sor r esi st an ce ou t of ran ge.
Inner Door Removal Procedure Step 1. Rotate the gas control knob to the “OFF” position. Step 2. Remove outer jacket burner access door Step 3. Inner Door Removal. a) Disconnect chamber door temperature sensor wire harness from the gas valve. b) Disconnect resettable thermal switch white wire lead (leading from gas valve).
Installation of Inner Door With Gasket. WARNING Stripped fastener connections may allow for seal breach of inner door. A seal breach may result in a fire or explosion causing property damage, personal injury or death. Do not over tighten screws in steps 8, 10 and 11.
Step 10. Firmly place right side inner door flange against the burner door flange and secure with two ¼” drive screws from step 3e. DO NOT OVER TIGHTEN SCREWS . Step 11. Align right side inner door to combustion chamber and verify the fastener holes of the combustion chamber are aligned with the right side inner door slotted opening.
Step 1. Closed circuit testing is t he preferred method for testing thermopile. Following the lighting instruction label on the heater, proceed to light the pilot and allow to operate for three minutes.
THERMOPILE REPLACEMENT Step 1. Turn off gas supply to water heater. Rotate gas control knob to the “OFF” position. Step 2. Remove outer jacket door. Step 3. Remove right side inner door and burner door per SERVICE PROCEDURE RG-I, steps 3a through 3g.
PILOT/ELECTRODE ASSEMBLY INSPECTION, CLEANING AND REPLACEMENT Step 1. Turn off gas supply to water heater. Rotate gas control knob to the “OFF” position. Step 2. Remove outer jacket door. Step 3. Remove burner and right side of inner door per SERVICE PROCEDURE ED-I, steps 3a through 3g.
IGNITER, ELECTRODE TESTING AND REPLACEMENT With the pilot not in operation (no pilot flame) you can check the igniter and electrode circuit by viewing pilot thru the sight glass located on the inner door and observing the spark action. SERVICE PROCEDURE ED -IV Igniter and Electrode Testing and Replacement Step 1.
Thermal Well Testing Thermal well testing Position gas control knob to the “OFF” position and disconnect thermal well harness from gas control. N Y Using a multi-meter set to the ohms setting, ins.
° F 012345678 9 40 2610 9 25400 24712 2404 5 23399 22771 22 163 21573 21000 20445 50 1990 6 19383 18876 1838 3 17905 17440 16 990 16553 16128 15715 60 1531 4 14925 14548 1418 0 13823 13477 13 140 128.
Gas Control & Thermal Well Removal From Water Heater Step 1. Turn the gas control knob to the “OFF” position. Step 2. Drain heater to a point below the gas control level. Step 3. Turn off gas supply to water heater and disconnect gas piping from gas control.
Gas Control Assembly to Thermal Well Step 6. Reconnect wire harnesses and igniter wire to gas control per the illustration to the left. Step 7. Reconnect gas piping to gas control.
Step 1. Turn the gas control knob to the “OFF” position Step 2. Disconnect the chamber sensor wire harness from the gas valve. Step 3. Remove the chamber door temperature sensor from the right side inner door (Phillips screw driver). Step 4. Make sure that the ring terminal of the chamber door temperature sensor is not touching any surface.
At periodic intervals (not more then 6 months) a visual inspection should be made of the main burner for proper operation and to insure no debris is accumulating. Main burner should light smoothly from pilot and burn with a blue flame with a minimum of yellow tips.
Step 5. Disconnect (unscrew) manifold mount from feed line. Use a stiff brush, compressed air and/or shop vacuum to remove any debris build up from the manifold mount. Step 6. Remove main burner orifice from feed line (3/8" wrench). Inspect and clean if necessary Step 7.
Step 1. Remove outer jacket door. Step 2. Disconnect white wire leads from resettable thermal switch. Step 3. Using a multimeter capable of measuring continuity (Ohms), place one probe of meter on one of the brass connection tabs of the resettable thermal switch, and the remaining probe on the other connection tab.
SERVICE PROCEDURE ED -VII Resettable Thermal Switch Testing and Replacement RESETTABLE THERMAL SWITCH REPLACEMENT Step 1. Rotate gas control knob to the “OFF” position. Step 2. Remove outer jacket door. Step 3. Disconnect wire leads from resettable thermal switch.
SERVICE PROCEDURE ED-VIII ScreenLok Flame Arrestor Cleaning Step 1. Rotate gas control knob to the “OFF” position. Step 2. Remove outer jacket door.
SERVICE PROCEDURE ED-IX Dip Tube and Anode Inspection and Replacement Page 24 Step 1. Rotate gas control knob to the “OFF” position. Step 2. Turn off cold water supply to water heater. Connect hose to drain spigot of water heater and route to an open drain.
Step 1. Turn off water supply to water heater. Rotate gas control knob to the “OFF” position. Step 2. Turn off cold water supply to heater. Connect hose to drain spigot of water heater and route to an open drain. Open a nearby hot water faucet to vent heater for draining.
1 Flue Baffle 2 Hot Water Outlet/Anode 3 Cold Water Inlet Tube 4 T&P Relief Valve 5 Thermal Well 6 Brass Drain Valve 7 Gas Valve 8 Main Burner Orifice 9 Heat Trap Inlet 10 Heat Trap Outlet 11 Oute.
27.
Email parts@bradfordwhite.com techserv@bradfordwhite.com www .bradfordwhite.com.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Bradford-White Corp U130T*FRN c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Bradford-White Corp U130T*FRN - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Bradford-White Corp U130T*FRN, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Bradford-White Corp U130T*FRN va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Bradford-White Corp U130T*FRN, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Bradford-White Corp U130T*FRN.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Bradford-White Corp U130T*FRN. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Bradford-White Corp U130T*FRN ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.