238-48248-00A 10/09 PE MODEL WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N 238-44219-00 (Replaces pg. 2 in instruction man u al.) CONGRATULATIONS! You have just purchased one of the fines t water.
2 Minimum Clearances (Replaces pg. 9 in instruction man u al.) WARNING Failure to adhere to these installation and oper ating instructions may create a hazard to life and property and w ill nullify the w arranty.
3 Lighting and Shutdown Instructions (Replaces pg. 18 in instruction man u al.) to light the pilot by hand. A. This appliance is equippe d with an ignition dev ice which automatically lights the pil ot.
4 THERMOSTAT ADJUSTMENT (Replaces pg. 19 in instruction man u al.) The thermostat dial is adjusted to its lowest setting w hen shipped from the factory. When adjusting the thermostat, it should be remembered that lower temperature settings are more energy efficient.
5 BURNER FLAME CHECK (Replaces pg. 22 in instruction man u al.) Steel Burner: These models are equipped with se lf adjusting air mixture and do not have an adjustable air shutter (See Figure 3). At periodic intervals, a visual check of the main burner and pilot flames should be made to determine if they are burning properly.
6 INSTALLATION FOR POTABLE WATER (Replaces pg. 28 in instruction man u al.) Figure 4.
7 PARTS LIST DRAWING (Replaces pg. 29 in instruction man u al.) Figure 5 1 3 4 5 6 7 8 9 10 12 13 14 15 16 15 A 19 20 21 22 23 24 25 27 28 11 26 2 18 17.
8 PARTS LIST (Replaces pg. 30 in instruction man u al.) PART NAME AND DESCRIPTION 1. Draft hood 15A. Resettable Thermal Switch 2. Setback Control Junction Box Assembly 16. Left side inner door 3. Jacket head 17. Accessory Module 4. Jacket 18. Junction box wire harness 5.
9 THE FOLLOWING INSTRUCTIONS ARE FOR INSTALLATION OF: GAS WATER HEATERS SUITABLE FOR WATER (POTABLE) HEATING AND SPACE HEATING (Replaces pg. 31 in instruction man u al.) All piping components connected to this water heater for space heating applications must be suitable for use with potable w ater.
10 (In addition to the instruction manua l.) origina l equipm ent. incident. Do not block or in any way restr ict jacket air inlet slots located at the bott om front of the w ater heater . Do not ope rate w ater h eater w it h j umpered , altered, loosely tightened o r absent contro ls and/or com ponents.
11 Electrical Connections (In addition to the instruction manua l.) All electrical wiring and connections must be in accordance w ith the National Electric Code ANSI/NFPA No. 70-Latest Edition, or the Canadian Electrical Code C22.1-Latest Edition, and any local codes w hich may apply.
12 Wiring Diagram (In addition to the instruction manua l.) 115 VOLTS 60HZ LESS THAN 12 AMPS IF ANY OF THE ORIGINAL WIRES SU PPLIED W ITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH APPLIANCE W IRE MATERIAL WIT H A MINIMUM TEMPERATURE RAT ING OF 105°C AND A MINIMUM SIZE OF NO.
13 TROUBLESHOOTING (In addition to instruction manual.) LE D S t a t us Cont rol St a t u s P robable Cause None ( LE D not on or f l a shin g) E l ec t r ic al p ow er n o t p res ent 1 .
14 Troubleshooting continued- LED S t a t u s Cont rol St at us Pro bable Cause S i x fl a s h e s , tw o f l ash es, t h r ee se c ond pa use ( S o ft L o c k o u t ) R e lay not w orking properly du.
15 Troubleshooting continued- Control Sequence of Opera tion Start up Sequence Upon powering up, the control checks for the presence of the flammable vapors, if the resistance is in the expect ed range the control will begin normal operation after 5 to 8 seconds.
16 Notes.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Bradford-White Corp 238-48248-00 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Bradford-White Corp 238-48248-00 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Bradford-White Corp 238-48248-00, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Bradford-White Corp 238-48248-00 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Bradford-White Corp 238-48248-00, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Bradford-White Corp 238-48248-00.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Bradford-White Corp 238-48248-00. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Bradford-White Corp 238-48248-00 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.