EN Operators Guide Solution-16, Solution-16 Safecom CC880/LP880, SC8016.
CC880/LP880, SC8016 | Operators Guide | EN | 2 Bosch Security Systems | 6/04 | 920036O.OG.162 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty Ltd (“ Bosch ”). All rights are reserved. You may download a single copy of this publication.
CC880/LP880, SC8016 | Operators Guide | EN | 3 Bosch Security Systems | 6/04 | 920036O.OG.162 Table of Contents 1.0 Introduction ...................................................... 5 2.0 Specifications ..............................................
CC880/LP880, SC8016 | Operators Guide | EN | 4 Bosch Security Systems | 6/04 | 920036O.OG.162 Tables Table 1: Specifications ............................................. 5 Table 2: Zone Indicator ........................................... 6 Table 3: AWAY Indicator .
CC880/LP880, SC8016 | Operators Guide | 1.0 Introduction EN | 5 Bosch Security Systems | 6/04 | 920036O.OG.162 1 .0 Int roduct ion Congratulations on selecting the Solution-16 Control Panel to protect you and your property. Take time to read through this manual and familiarise yourself with the operating features of this system.
CC880/LP880, SC8016 | Operators Guide | 3.0 Codepad Indicators EN | 6 Bosch Security Systems | 6/04 | 920036O.OG.162 Figure 3: CP5 Eight Zone LCD Codepad Figure 4: Sixteen Zone LCD Codepad The codepad is the communications interface between you and your alarm system.
CC880/LP880, SC8016 | Operators Guide | 4.0 Arming the System EN | 7 Bosch Security Systems | 6/04 | 920036O.OG.162 3.4 System Disarmed This indicator displays with the indicator when the system is disarmed. 3.5 MAINS Indicator The MAINS indicator displays that the systems AC mains supply is normal or failed.
CC880/LP880, SC8016 | Operators Guide | 4.0 Arming the System EN | 8 Bosch Security Systems | 6/04 | 920036O.OG.162 4.1 Forced Arming Forced arming arms the system when a zone is not sealed. If the system does not arm and a long beep is heard, forced arming is not permitted.
CC880/LP880, SC8016 | Operators Guide | 5.0 Disarming the System EN | 9 Bosch Security Systems | 6/04 | 920036O.OG.162 How to Arm the System in STAY Mode 2 Hold down the [0] button until two beeps are heard. The STAY indicator displays and exit time starts counting.
CC880/LP880, SC8016 | Operators Guide | 8.0 Codepad Duress Alarm EN | 10 Bosch Security Systems | 6/04 | 920036O.OG.162 8.0 Codepad Duress Alarm A codepad duress alarm is used as a silent hold-up alarm. This only occurs when the number “9” is added to the end of any valid user code being used to disarm the system (for example, [2 5 8 0 9 #]).
CC880/LP880, SC8016 | Operators Guide | 14.0 Fault Analysis Mode EN | 11 Bosch Security Systems | 6/04 | 920036O.OG.162 13.1 Standard Isolating Standard isolating allows all operators to isolate zones without knowing a valid user code. How to Isolate a Zone 1.
CC880/LP880, SC8016 | Operators Guide | 15.0 Date and Time EN | 12 Bosch Security Systems | 6/04 | 920036O.OG.162 Horn Speaker Fail A horn speaker failure fault registers when the system detects that the horn speaker is disconnected. This fault clears once the horn speaker is reconnected.
CC880/LP880, SC8016 | Operators Guide | 17.0 Reset Latching Outputs EN | 13 Bosch Security Systems | 6/04 | 920036O.OG.162 1 7 .0 Reset Lat ching Out put s This feature is only applicable if your installer programmed an output to latch (remain on) until you acknowledge the event that occurred.
CC880/LP880, SC8016 | Operators Guide | 21.0 Codepad ID and Buzzer Tone EN | 14 Bosch Security Systems | 6/04 | 920036O.OG.162 2 1 .0 Codepad I D and Buzzer T one If you press and hold down button [8], the tone of the codepad buzzer changes. There are 50 different tones to choose from between 1500 Hz and 5000 Hz.
CC880/LP880, SC8016 | Operators Guide | 23.0 Remote Arming By Telephone EN | 15 Bosch Security Systems | 6/04 | 920036O.OG.162 Example If the AREA DISPLAY displays number 2, all operations performed only operate Area 2. To operate Area 1, you need to press the [#] key until the AREA DISPLAY displays number 1.
CC880/LP880, SC8016 | Operators Guide | 25.0 Domestic Dialling EN | 16 Bosch Security Systems | 6/04 | 920036O.OG.162 25.0 Domest ic Dialling Use domestic dialling to call your mobile phone or a relative/friend in the event your control panel activated an alarm.
CC880/LP880, SC8016 | Operators Guide | 26.0 Domestic Voice Message Reporting EN | 17 Bosch Security Systems | 6/04 | 920036O.OG.162 26.0 Domest ic V oice Message Report ing The system can be configured by your security company to report to your mobile phone when an alarm occurs and play back a pre-recorded message detailing instructions.
CC880/LP880, SC8016 | Operators Guide | 27.0 Basic Pager Reporting EN | 18 Bosch Security Systems | 6/04 | 920036O.OG.162 Figure 8: Basic Pager Display Zone Normal - 0 Alarm - 1 Zone Bypassed - 2 Zone.
CC880/LP880, SC8016 | Operators Guide | 28.0 PET Pager Reporting EN | 19 Bosch Security Systems | 6/04 | 920036O.OG.162 28.0 P ET Pager Report ing The system can be configured by your security company to report to a pocket pager when an alarm and/or any system event occurs.
CC880/LP880, SC8016 | Operators Guide | 29.0 Glossary of Terms EN | 20 Bosch Security Systems | 6/04 | 920036O.OG.162 29.0 Gloss ary of T erms Table 19: Glossary of Terms Term Description 24-Hour Zones A monitored input programmed to trigger an alarm condition when violated when the system is armed or disarmed 24 hours a day.
CC880/LP880, SC8016 | Operators Guide | 29.0 Glossary of Terms EN | 21 Bosch Security Systems | 6/04 | 920036O.OG.162 Table 19: continued Term Description Phone Controller The phone controlle r can be used to turn your system on in AWAY Mode via the telephone by generating a tone.
CC880/LP880, SC8016 | Operators Guide | 30.0 Installation Notes EN | 22 Bosch Security Systems | 6/04 | 920036O.OG.162 30 . 0 In sta ll ati on N ote s Installation Company Technician’s Name Technici.
CC880/LP880, SC8016 | Operators Guide | 30.0 Installation Notes EN | 23 Bosch Security Systems | 6/04 | 920036O.OG.162 Zone Description Describe each zone and mark which zones were programmed to be automatically isolated in STAY Mode 1 or were programmed for day alarm operation.
CC880/LP880, SC8016 | Operators Guide | 30.0 Installation Notes EN | 24 Bosch Security Systems | 6/04 | 920036O.OG.162 User Code Names Master Code Master Code Default = 2580 User Code 1 Y User Code 17.
CC880/LP880, SC8016 | Operators Guide | 30.0 Installation Notes EN | 25 Bosch Security Systems | 6/04 | 920036O.OG.162 Entry/Exit Times Entry Timer 1 Exit Time Entry Timer 2 Entry Guard Time Entry Tim.
CC880/LP880, SC8016 | Operators Guide | 30.0 Installation Notes EN | 26 Bosch Security Systems | 6/04 | 920036O.OG.162 Communication Options Back To Base Reporting YES NO Panel Account Number Domestic.
CC880/LP880, SC8016 | Operators Guide | Index EN | 27 Bosch Security Systems | 6/04 | 920036O.OG.162 Index 24-Hour Zones ...................................................... 19 A Adding User Codes ................................................ 8 Alarm Condition.
CC880/LP880, SC8016 | Operators Guide | Index EN | 28 Bosch Security Systems | 6/04 | 920036O.OG.162 Zone Indicators ................................................. 13 Medical Alarm ........................................................ 9 Monitoring Station .
CC880/LP880, SC8016 | Operators Guide | Index EN | 29 Bosch Security Systems | 6/04 | 920036O.OG.162 Notes:.
CC880/LP880, SC8016 | Operators Guide | Index EN | 30 Bosch Security Systems | 6/04 | 920036O.OG.162 Notes:.
CC880/LP880, SC8016 | Operators Guide | Index EN | 31 Bosch Security Systems | 6/04 | 920036O.OG.162 Notes:.
© 2003 Bosch Security Systems 920036O 4998152460B Issue 1.62 Bosch Security Systems 25 Huntingwood Drive Huntingwood NSW 2148 Australia Phone: +612 9672 1777 Facsimile: +612 9672 1717.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Bosch Appliances CC880 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Bosch Appliances CC880 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Bosch Appliances CC880, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Bosch Appliances CC880 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Bosch Appliances CC880, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Bosch Appliances CC880.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Bosch Appliances CC880. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Bosch Appliances CC880 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.