Aller à la page of 16
W ARNING : Improper inst allation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer , service agency or the gas supplier .
2 Principle of Operation: When a hot water faucet is opened, the water flow through the heater causes the gas valve to open. At the same time a microswitch is activated which sends a spark to the pilot. The flame sensor confirms the pilot has been lighted and allows the first two burners to come on.
3 MINIMUM INST ALLA TION CLEARANCES FROM COMBUSTIBLE AND NON COMBUSTIBLE MA TERIALS FOR ALCOVE OR CLOSET INST ALLA TIONS FRONT VIEW SIDE VIEW AQUAST AR MODEL 125X D870_072 M ODE L 125 X T O P ( A ) 12.
4 GENERAL RULES TO FOLLOW FOR SAFE OPERA TION 1. Y ou should follow these instructions when you install your heater . In the United S tates: The installation must conform with local codes or , in the absence of local codes, the National Fuel Gas Code ANSI Z223.
5 Louvers, grills and screens have a blocking effect. If the effective free area is not known, increase the sizes of your openings by 75% if your louvers are wood and by 30% if your louvers are metal. Refer to the National Fuel Gas Code for complete information.
6 Fig. 2 - Incandescent Particle T ray Illustration at least 1/4 inch for every foot of its horizontal length. Keep the horizontal section short and avoid too many elbows. T o check the draft: Close all doors and windows to the outside. Turn on all appliances that force air out of the building.
7 GAS CONNECTIONS and Gas Regulator Before connecting the gas supply , check the rating plate on the right side of the front cover to be sure that the heater is rated for the same gas to which it will be connected.
8 OPERA TING INSTRUCTIONS Before proceeding with the operation of the heater make sure that the system is filled with water . Open the cold water inlet supply to the heater fully .
9 The position you select on the temperature adjustment knob will depend on the temperature of the incoming water (50 ° F is average in the U.S.). In warm weather regions where the incoming cold wate.
10 MAINTENANCE AND SERVICE REVIEW MAINTENANCE T ABLE ON THE BACK OF THIS MANUAL Approximately once a year , the AquaS tar should be checked and cleaned. T o remove the front cover , first remove the incandescent particle tray , then pull of f the temperature adjustment knob and unscrew and remove the plastic collar .
11 NO SP ARK A T THE PILOT 1. On/Off switch is not ”On” (Position I ). The On/Off switch is located behind the flipdown cover plate on the front panel strip. See fig. 9. 2. Water flow is not sufficient to activate heater . W ater flow rate at faucet is below minimum flow needed to activate heater .
12 Fig. 13 - Electrical wiring diagram E661_002 WA TER IS NOT HOT ENOUGH 1. T emperature selection too low. Change the setting. T urn the temperature adjustment knob clockwise (to the right).
13 5 11 1 4 9 10 3 12 2 6 7 8 Fig. 14 - Diagram of AquaStar 125 X 1. Heat exchanger 2. Pilot assembly 3. Burner manifold gas pressure test nipple 4. Main gas burner 5. Pilot gas tubing 6. Gas valve 7. Electronic control box 8. Battery box 9. on/of f switch 10.
14 Fig. 15 - INTERIOR COMPONENTS DIAGRAM AND P ARTS LIST.
15 Fig. 15 INTERIOR COMPONENTS DIAGRAM AND P ARTS LIST 125X 1 Front cover ¤ 8 705 421 255 2 T emperature adjustment knob comp. ¤ 8 702 000 219 3 T emperature adjustment knob ¤ 8 702 000 1 1 1 4 W a.
0 1 e g a p e e s E L B A T E C N A N E T N I A M R A E Y Y R E V ES R A E Y 2 Y R E V ES R A E Y 5 - 3 Y R E V E E V L A V R E T A W E T A C I R B U L † E V L A V R E T A W D L I U B E R † N E E .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Bosch Appliances 125X LP c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Bosch Appliances 125X LP - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Bosch Appliances 125X LP, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Bosch Appliances 125X LP va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Bosch Appliances 125X LP, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Bosch Appliances 125X LP.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Bosch Appliances 125X LP. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Bosch Appliances 125X LP ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.