Manuel d'utilisation / d'entretien du produit BOGEN WV100 du fabricant Bogen
Aller à la page of 16
W all-Mount Power V ector Amplifiers WV100, WV150, & WV250 Models Inst allation and Use Manual © 2002 Bogen Communications, Inc. All rights reserved.
Notice Every effort was made to ensure that the information in this guide was complete and accurate at the time of printing. How ev er , information is subject to change. Important Safety Information W ARNING: T o Reduce The Risk of Fire Or Electric Shock, Do Not Expose This Apparatus T o Rain Or Moisture.
Contents Page P ANEL DESCRIPTIONS..................................................................................................2-3 W all-Mount Po w er V ector Front Panel ............................................................................
P anel Descriptions W all-Mount Po wer V ector Fr ont P anel 1 . Input V olume Control Each of the 8 module ba ys are controlled b y an independent v olume contr ol. 2. Signal / Clip Indicator A single two-color LED located abov e each channel’ s volume control indicates the audio activity of that chan- nel’ s input.
P anel Descriptions W all-Mount Po wer V ector Module Bay (Rear) 1 . Module Ba ys The amplifier has eight module ba ys, all of which can accommodate input modules, with two ba ys (ba ys 7 and 8) that can accommodate either input or output modules.
Installation P ackage Contents • Amplifier • 2 Cables • Instruction Manual • Combined XLR receptacle and phone jack • 2 Scre ws (M 3 x 8) • 6 Scre ws (M 4 x 8) Mounting A surface-mount (model BBS) or flush-mount (model BBF shown below) back bo x as w ell as a WMAD door is requir ed for installation.
Modules Module Installation Eight module ba ys are a vailable to accept Bogen’ s new advanced plug-in input modules. Module ba ys 7 & 8 can also accommodate Bogen’ s new advanced plug-in output modules, thereby allo wing users to customize the amplifier to suit the needs of the installation.
Connections Speakers T ransf ormer -Coupled Speaker Connections T ransf ormer -coupled, constant voltage speak er loads ar e connected to their respectiv e load type (i.e ., 70V speak ers to the 70V terminal, 25V speaker systems to the 25V terminals) and the COM terminal.
Connections COM and GND T erminals A shorting jumper typically connects the COM and GND terminals of the amplifier together . The COM terminal is a common lead from the output transformer . For the transformer -coupled speak er output to work, one of the speak er load leads must be connected to this terminal.
8 Connections System Expansion of Po wer V ector Amplifier s Using the bridging RCA connector , it is possible to connect two or mor e Pow er V ector amplifiers. It is not rec- ommended that more than thr ee amplifiers be bridged together due to bridging loss.
Operation Fr ont P anel Controls & Indicators Input V olume Contr ols Each input module ma y be individually controlled by its cor r esponding volume control knob . Signal / Clip Indicator A single LED located above each channel’ s volume contr ol indicates the audio activity of that channel’ s input.
10 Operation Output Limiter The Output Limiter control sets the thr eshold at which the unit hard limits the output signal. Once the Limiter's threshold is exceeded, the output signal is pre vented from incr easing any further .
Block Dia gram 11.
12 Specifications P o wer Output (RMS): WV 1 00: 1 00W ( 1 40W T ypical, @ 1 kHz/0. 1% /4 Ω) WV 1 50: 1 50W (200W T ypical, @ 1 kHz/0. 1% /4 Ω) WV250: 250W (340W T ypical, @ 1 kHz/0. 1% /4 Ω) Fr equency Response T ransf ormer : 45-20 kHz; 0/-2 dB @ FRP Direct: 20-20 kHz; 0/- 1 dB @ FRP Distortion T ransf ormer : 0.
T r oubleshooting 13 • Amplifier not plugged in. • A C outlet dead. • Po w er switch off. • Circuit br eaker tripped. • Speak er connections on amplifier ar e incorr ect. • T rans / Direct Out selector not set corr ectly . • Poor / br oken speak er wiring.
50 S pring S treet, Ramsey , NJ 07446, U.S.A. T el. 201-934-8500, Fax: 201-934-9832, www .bogen.com W arranty Bogen W all-Mount Pow er V ector Amplifiers, modules, and components ar e warranted to be .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Bogen BOGEN WV100 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Bogen BOGEN WV100 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Bogen BOGEN WV100, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Bogen BOGEN WV100 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Bogen BOGEN WV100, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Bogen BOGEN WV100.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Bogen BOGEN WV100. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Bogen BOGEN WV100 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.