Manuel d'utilisation / d'entretien du produit 9010 du fabricant Bloomfield
Aller à la page of 26
PRINTED IN UNITED ST A TES OF AMERICA WELLS BLOOMFIELD , LLC 2 ERIK CIRCLE, P . O. Box 280 V erdi, NV 89439 telephone: 775-689-5707 fax: 775-689-5976 www .
601 75815 Owners Manual Integrity Decanter Brewers NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged by skilled personnel before leaving the factory. Upon acceptance of this shipment, the transportation company assumes full responsibility for its safe delivery.
TABLE OF CONTENTS Thank You for purchasing this Wells Bloomfield appliance. Proper installation, professional operation and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long, economical service life.
FEATURES AND OPERAT ING C ONT ROLS Fig. 1 Features & Operating Controls 2 601 75815 Owners Manual Integrity Decanter Brewers.
PRECAUTIONS AND GE NERAL INFORMATION WARNING: ELECTRIC SHOCK HAZARD All servicing requiring access to no n-in sulat ed components must be performed by qualified service personnel. Do not open a ny access pan els which requi re t he use of tools. Failure to heed this warning can result in electrical sho c k.
INSTALLATION INSTRUCTIO NS READ THIS CAREFULL Y BEFORE ST ARTING THE I NST ALLA TION Unpack the unit. Inspect all component s for completeness and condition. Ensure that all packing materials have bee n remove d from the unit. Verify that the Spray Head Gasket and Spray Disk are prop erly installed.
INSTALLATION INSTRUCTIO NS (co ntinued) NOTE: This equipment m ust be installed to comply with applicable federal, state and local plumbing codes and ordinances. WARNING: SHOCK HAZARD Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a plumbing line wil l provide such a ground.
OPERATION Fig. 4 Brewer Operation Diagram A. START-UP For initial start-up, or if the bre we r ha s n ot been used for an extended period of time: ♦ Be sure spray disk and brew gasket are prop erly installe d in the brew head. ♦ Be sure the water sup ply is properly conne cted and the water supply valve is turned ON .
OPERATION (continued) WATER HEATER Water temperature is sen s ed by a thermobulb inserted into the water tank. This temperature signal is fed to the thermostat, which controls line power to the heating element. The setpoint temperature is adjustable at the thermostat.
BREWING COFFEE CAUTION: BURN HAZARD Exposed surfaces of the brewer, brew chambe r and decanter may be HOT to the touch, and can cause serious burn s. CAUTION: BURN HAZARD To avoid splashing or over- flowing hot liquids, ALWAYS place an empty decanter under the brew chamber before starting the brew cycle.
CLEANING INSTRUCTIONS PROCEDURE: Clean Coffee Brewer PRECAUTIONS: Disconnect br ewer from electric power. Allow brewer to cool. FREQUENCY: Daily TOOLS: Mild Detergent, Clean Soft Cloth or Sponge Bristle Brush. 1. Disconnect brewer from electric power.
10 TROUBLESHOOTING SUGGESTIONS SUGGESTED REMEDY Check power sup ply cord Check / reset cir cuit breaker Set for desired temperature Allow to cool Reset hi-limit (8786, 8788) Examine wiring & conne.
SERVICING INSTRUCTIONS ACCESS PANELS Each warmer plate has a center stud wh ich screws int o a bracket. Warmer plates on Canadian br ewe rs are secured with a nut. Remove button plug on bottom of brewer to access nut on main warmer. Remove top panel to access nuts o n top wa rmers.
SERVICING INSTRUCTIONS (continued) TEMPERATURE ADJUSTMENT Unplug power cord o r turn circuit breaker OFF. Remove top panel. Pull vent tube out of tank lid and insert a thermometer of known accuracy in vent hole. Reconnect brewer to elect rica l powe r.
SERVICING INSTRUCTIONS (continued) 13 601 75815 Owners Manual Integrity Decanter Brewers IMPORTANT: Water p ressure must be between 20 p.s.i and 90 p.s.i. flowing pressure. If water pressure exceeds this value, or if water pressure varies greatly, a pressure regulator must be installed in the water supply line.
SERVICING INSTRUCTIONS (continued) 14 REPLACE HEATING ELEMENT Remove tank lid assembly as described on pag e 13. Remove two hex nuts holding element to cover. Pull element from mounting holes. Reassemb le in revers e order. REPLACE SOLENOID Symptom: Automatic brewer will not flow water; or, automatic brewer drips continuou sly from bre w head.
SERVICING INSTRUCTIONS (continued) 15 IMPORTANT: When repl acing water faucet coil, also replace seal gaskets. NOTE: Any abrasion or roughness on the flat end of the seat cup will require replacing the seat cup: Work the seat cup out of the bonnet and off of the end of the stem.
CAUTION: CHEMICAL BURN HAZARD Deliming chemicals may be caustic. Wear appropriate protective gloves and goggles during this procedure. Never siphon deliming chemicals or soluti o ns by mouth. This operation should only be performed by qualified and experienced service personnel.
7. Set the tank back into the brewer. Reassemble the tank lid to the water tank. Make sure the gasket is properly in place, then reinstall the hold-down strap. 8. Reinstall wiring to heating element and thermostat. Reinstall the hi-limit thermostat (if removed).
EXPLODED VIEW & PARTS LIST 18 HOT WATER TANK ASSEMBLY 601 75815 Owners Manual Integrity Decanter Brewers 68 56 57 58 63 56 61 50 52 62 55 54 70 66 66a 13 67 66b 59 60 14 AL TERNA TE 50 ITEM P ART NO. DESCRIPTION USED ON 13 8043-5 HOLD -DOWN STRAP 9010, 9012(CA), 9016(EX) 50 8512-51 86280 THERMOSTAT (BLACK BODY - INCL.
EXPLODED VIEW & PART S LIST (continued) 19 601 75815 Owners Manual Integrity Decanter Brewers 33 34 25 24 34a 19 43 26 28 11 27 29 60 8 10 12 45 9 29a 29b 29c 29d 29e 29f 29g 29h 29j 29k T ANK ASSY see P AGE 18 61 59 18 CABINET PLUMBING CO MPONENTS ITEM PART NO.
EXPLODED VIEW & PART S LIST (continued) 20 601 75815 Owners Manual Integrity Decanter Brewers ELECTRICAL COMPONENTS ITEM P ART NO. DESCRIPTION USED ON 2 8572-18 8533-32 HEATING ELEMENT, WARMER 120.
EXPLODED VIEW & PART S LIST (continued) CABINET COMPONENTS 21 601 75815 Owners Manual Integrity Decanter Brewers ITEM PART NO. DESCRIPTION USED ON 3 8700-16 COVER PLA TE, WARMER BLACK 9010, 9012 (.
WIRING DIAGRAMS 22 601 75815 Owners Manual Integrity Decanter Brewers 123 123 123 READY LIGHT BREW SWITCH WARMER SWITCH WARMER SWITCH WARMER SWITCH SOLENOID THERMOST A T TIMER HI-LIMIT BLACK BLACK ORA.
WIRING DIAGRAMS ( continued) 23 601 75815 Owners Manual Integrity Decanter Brewers TIMER GREEN LINE LINE NEUT GND 123 123 123 READY LIGHT BREW SWITCH WARMER SWITCH WARMER SWITCH WARMER SWITCH SOLENOID.
Genuine Parts Protect - YOU - All - W ays SER VICE TRAINING - QUALITY SERVICE SER VICE TRAINING - QUALITY SERVICE CUSTOMER SA TISF ACTION CUSTOMER SA TISF ACTION Wells Bloomfield proudly supports CFES.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Bloomfield 9010 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Bloomfield 9010 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Bloomfield 9010, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Bloomfield 9010 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Bloomfield 9010, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Bloomfield 9010.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Bloomfield 9010. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Bloomfield 9010 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.