Manuel d'utilisation / d'entretien du produit 2086EX du fabricant Bloomfield
Aller à la page of 28
PRINTED IN UNITED STATES OF A MERIC A p/n 73574 Rev. S ECN-1281 7 M652 05 0208 cps 652 OWNERS MANUAL for E-Max™ AIRPOT and THERMAL COFFEE BREWERS MOD EL S 2080 2082 2086 2086EX 2088 2088E X Includes: Installation Operation Use & Care Servicing Instructions Model 2082 Airpot Brewer with optional 7759 Airpot E-Max BREWERS are cov ered under U.
NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged b y skilled personnel before le aving the factory. Upon acceptance of this shipm ent, the transportation company assumes full responsibility for its safe delivery.
TABLE OF CONTENTS SPECIFICATIONS Thank You for purc hasing this Bloomfield Industries appliance. Proper installation, professional operation and consistent maintenance of this appliance w ill ensure that it gives you the very best performance and a long, economical service life.
FE AT U R E S AN D O P E R AT I N G CO N T R OL S 2.
WARNING: Electric Shock Hazard All servicing requiring access to non-insu lated components must be performed by qualified service personnel. Do not open any access panels wh ich require the use of tools. Failure to heed this warning can re su lt in electrical shock.
INSTALLATION INSTRUCTIONS RE A D THIS CAREFULL Y BEFORE ST A RTING THE INST A LLA TION UNPACKING & INITIAL INSPECTION 1. Unpack the unit. Inspec t all com ponents for completeness and condition. Ensure that all pack ing materials have been rem oved from the unit.
INSTALLATION INSTRUCTIONS (continued) NOTE: This equipment must be installed to comply with applicable federal, state an d local plum bing codes an d ordinanc es. WARNING ELECTRIC SHOCK HAZARD: Brewer must be properly grounded to prevent possible shock hazard.
OPERATION IMPORTANT: All E-Max™ brewers are tested and set a t the facto ry . If programming adjust- ments are necessary, refer to the E -Ma x™ Programming Manual (p/n/73674). To over-ride th e Br ew Wait mode , press and hold the BR EW key for 3 second s when the brewer is in Bre w Wait mode (i.
OPERATION (continued) W ARNING: Burn Hazard. This appliance dispenses very hot liquid. Seriou s bodily injury from scalding can occur f rom co ntact with dispensed liquids. C AUTION: B urn Hazard To avoid splashing or overflowing ho t liquids, ALWAYS use an empty airpot or therm al server before starting th e brew cycle.
PROGRAMMING FEATURES AND OPTIONS 1. View Water Temperature in Tank: To view the water tem perature on the scre en, the E-Ma x™ brewer must be ON, and not brewing or in the filling mode. Press and hold the 4th key, and depress the 6th key. The actual wa ter temperature w ill be displayed for 3 seconds.
8. Clock A. Time – Battery Backup. The E-Max™ has a battery backup s ystem which will maintain the proper time during power failures, or when the bre wer is unplugged (even f or very prolonge d periods of time).
OPERATION (cont inued) 12. View Filter Statistics: To view filter stat istics, turn the brewer off . Press and ho ld the 1st k ey (Brew), and depress the 3rd (ON/OFF) k ey. Total water volume will be displayed (TotalVol.). Press the 3rd key to view the Filter Lif e (F ltrLife:).
CLEANING I NSTRUCTIONS PROCEDURE: Clean Coffee Br e wer PRECAUTIONS: Disconnect bre wer from electric power. Allow brewer to cool. FREQUENCY: Daily TOOLS: Mild Detergent, Clean So ft C loth or Sponge Bristle Brush 1. Dis connect bre wer from electric po w er.
FUNCTION 1. W ater enters at the inlet fitt ing of the fill solenoid (32). The solenoid adm its water via a command from the controller. NOTE: The solenoid has an inter nal strainer. To clean the strain er: Shut of f water supp ly. Unscrew the plastic ca p protruding from the rear of the brewer.
SERVICING IN STRUCTIONS — PLUM BING (continued) ITEM DESCRI PTIO N P ART N0. USED ON 1 2 A SSEMB L Y , WA TE R T ANK (120 V) 83500 201 2, 2072 2015 , 207 5 6 G ASKE T , T ANK LID 83499 AL L 9 T AN K L ID 83504 AL L 10 RET A INING CLIP , T ANK LID 835 06 ALL 1 1 HOSE, OV ERF LOW ( 2 pc SI LI CO N E 4.
SERVICING INST RUCTIONS - ELECTRIC AL FUNCTION 1. Pressing th e POWER k ey energizes the unit. The POWER LED will glow whenever the unit is ON . 2. Automatic fill is accomp lished via a FI LL SOLENOID (32) and a W ATER LEVEL PROBE (7). The probe senses ground through the water in the tank.
SERVICING IN STRUCTIONS - ELECTRIC AL (continued) 15 ITEM DESC R IP TI ON P AR T N0. USED ON 3 PROBE, TEMPERA TUR E 83480 A LL 4 T HERMO S T A T , H I-L IMIT S AF E TY (1 20 V) 839 4 9 2080, 20 82 5 G.
SERVICING INSTRUCTIONS — DE-LIMING HE A TER TANK 1. Disconnect br e wer form the electrica l sup pl y. Turn off the water suppl y and disc onnect water supply f rom the brewer inlet fitting. 2. Rem ove the top panel or top warmer section to gain access to internal components.
TROUBLESHOOTING SUGGESTIONS If the E-Max™ goes into the error diagnostic mode as outlined below , it will likely be necessa ry to reset the brew er in ord er to test individual components.
EXPLODED VIEW & PARTS LIST 18 AIRPOT BREWER MODELS: 2082, 2083, 2088.
EXPLODED VIEW & PARTS LIST (continued) 19 ITEM PART # DESCRI PTION QT 1 8763-1 FAUCE T HOT W ATE R 1 2 83500 83753 84010 TANK ASST 8 QT TANK ASSY 8 QT 240V TANK ASSY 8 QT DUAL VOLTAGE 1 3 83480 TH.
EXPLODED VIEW & PART S LIST (continued) 20 THERMAL BREWER MODELS: 2080, 2085, 2086.
EXPLODED VIEW & PARTS LIST (continued) 21 ITEM PART # DESCRIPTION Q 1 8763-1 FAUCET HOT WATER 1 2 83500 83753 84010 TANK ASST 8 QT TANK ASSY 8 QT 240V TANK ASSY 8 QT DU AL VOLTAGE 1 3 83480 THERMI.
WIRING DIAG RAMS MODEL 2080 & 2082 120 VOLT BREWERS AIRPOT and THERMAL 22 White #8 White #9 White #1 1 Red #3 Black #7 Black #6 Brown #1 Orange/ Black #4 Orange/ Black #5 Red #3 Bro wn #1 Blue #2 Blue #2 Black #6 White #9 White #10 White #8 14 ga .
WIRING DIAGRA MS (continued) MODEL 2086 & 208 8 120/240 VOLT BREWERS AIRPOT and THERMAL 23 Black #12 B l a c k # 4 B l a c k # 5 Red #10 1 2 3 4 Red # 3 Red # 3 Brown #1 Blue #2 Blue #2 Black #6 B.
WIRING DIAGRAMS (continued) 24 MODEL 2086EX & 2088EX 240 VOLT BREWERS AIRPOT and THERMAL.
NOTES 25.
PRINTED IN UNITED STATES OF AMERICA Bloo mf iel d Indu stri es, Inc . Division of Carrier Co mmercial Refrigeration In US and Can ada T elep hone: 775 -689- 5700 Fa x: 888-4 92-2783 Fa x: 800-3 56-5142 () websi te: www .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Bloomfield 2086EX c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Bloomfield 2086EX - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Bloomfield 2086EX, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Bloomfield 2086EX va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Bloomfield 2086EX, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Bloomfield 2086EX.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Bloomfield 2086EX. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Bloomfield 2086EX ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.