INTRODUCTION SAFETY WARNINGS AND PRECAUTIONS xi The technical co ntent of this ma nual represe nts current prod uc tio n m odels as of October, 2003. Data, specifications and materials, and model number designations are subject to change at an y time w ithout no tice.
1 TABLE OF CONTENTS INSTALLATION PROCEDURES …………………………………….. 2 BREWER OVERALL CHECKOUT ……………………………………. 4 BREWING COFFEE …………………………………………………… 5 CLEANING INSTRUCTIO NS ………………………………………….
INSTALL ATION 2 RE A D THIS CAREFULL Y BEFORE ST ARTING THE INST A LLA TION This general information may not apply to all models. Ref er to the owners manual and any te chnical data sheets for your specific equipment for a dditional information. PREPARATION Unpack the unit.
INSTALLATION (continued) 3 NOTE: This equipment must be installed to comply with applicable federal, state an d local plum bing codes an d ordinanc es. WARNING: SHOCK HAZARD Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a plumbing line will provide suc h a ground .
4 BREWER OVERA LL CHECK-OUT BREWER CHECK-OUT These checks should be performed: • When th e brewer is installe d • During any service call on the brewer • During any subseq ue nt follow-up call IMPORTANT: Tank must be full of water bef ore pressing POW ER key " ON ".
BREWING COFFEE PREPARATION Place on e (1) genuine Bloomfield pa per filter in the brew chamber. Add a pre-measured a mount of fresh coffee gr ounds. Ge ntly shake the brew chamber to level the bed of grounds. Slide the brew chamber into place under the brew head.
CLEANING INSTRUCTIONS PROCEDURE: Clean Coffee Brew er PRECAUTIONS: Disconnect brew er from electric pow e r. Allo w brewer to cool. FREQUENCY: Dail y TOOLS: Mild Detergent, Clean So ft Cloth or Sponge Brist le Brush, Bottle Brush 1. Disconnect brewer from electric power.
THEORY OF OPERATION 7 POUR-OVER FEATURE Pouring any amount of cold wate r into the pour-over opening and into the basin pan forces an identical amount of hot water out of the tank and through the spray he ad into the brew chamber.
The faucet water coil is submerged in the hot water tank an d draws heat from t he bre w water. Faucet water flows through the bypass side of the water inlet and is not cont ro lled by the solenoid val ve. The fauc et is at supp ly water pressure any time the faucet shut-off valve is O PEN .
THEORY OF OPERATION (continued) Heat Control Diagram The heating elements are energized when line power is applied to the elem ent term inals. Water temperature is sensed by a thermobulb inserted in to the water tank.
TROUBLESHOOTING GUIDE 10 QUICK GUIDE The first step in troubleshooting is to determine w h ere to start. A few simple checks should quickly point to the major area of concern.
TROUBLESHOOTING GUIDE (continued) 11 BREW W ATER SY STEM - AUTOMATIC OPERATION.
TROUBLESHOOTING GUIDE (continued) 12 BREW W ATER SYSTEM - AUTOMATIC OPERATION.
.
TROUBLESHOOTING GUIDE (continued) 14 BRE W W ATER SYSTEM - AUTOMA TIC OR POUR-O VER OPERATION.
TROUBLESHOOTING GU IDE (continued) 15 BREW W ATER SY STEM - POUR-OVER OPERATION.
TROUBLESHOOTING GUIDE (continued) 16 FAUCET W ATER SYSTEM.
TROUBLESHOOTING GU IDE (continued) 17 FAUCET W ATER SYSTEM.
TROUBLESHOOTING GUIDE (continued) 18 FAUCET W ATER SYSTEM.
TROUBLESHOOTING GU IDE (continued) 19 ELECTRICAL SYSTEM - BREW CA UTIO N: ELECTRIC SHOCK HA ZARD Exposed electric circuits. Use due caution when work in g near live ele ctric circuits.
TROUBLESHOOTING GUIDE (continued) 20 ELECTRICAL SYSTEM - HEATING.
.
SERVICING INSTRUCTIONS 22 TEMPERATURE ADJUSTMENT Unplug power cord or turn circuit breaker OFF. Remove top panel. Pull vent tube out of tank lid an d insert a thermometer of known accuracy in vent hole. Reconnect brewer to electrical power. Place an empty decanter under brew chamber.
SERVICING INST RUCTIONS (continued) 23 IMPORTA NT: Water pressure must be betwee n 20 p.s.i and 90 p.s.i. flowing pressure. If wate r pressure ex ceeds this value, or if water pressure varies g reatly, a pres sure regulator must be installed in the w ater sup ply line.
.
25 SERVICING INST RUCTIONS (continued) IMPORTA NT: When replacing water faucet coil, also rep l ace seal gaskets. NOTE : Any ab ra sion or roughness on the flat end of the seat cup will re quire replacing the seat cup: Work the seat cup out of the bonnet and off of the end of the stem.
26 CA UTIO N - CH EMICA L BU RN HA Z A RD Deliming chem icals are caustic. W ear ap pr op riate pr ote ct ive gloves and goggles during this procedure. Never siphon deliming chemicals or solutions by mou th. This operation should only be perfo rm e d by qualifie d an d ex- perienced service personnel.
27 7. Set the tank ba ck into the brewer. Reassem b le the tank lid to the water tank. Mak e sure the gasket is properly in place, then reinstall the hold-do wn strap. 8. Reinstall wiring to heating element a nd thermostat. Reinstall the hi-lim it thermostat (if removed).
Bloo mf iel d Indu str i es, Inc . Division of Carrier Co mmercial Refrigeration In US and Can ada T elep hone: 775 -6 89-5700 Fa x: 888 -492- 2783 Fa x: 800 -356- 5142 () websi te: www .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Bloomfield 1000 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Bloomfield 1000 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Bloomfield 1000, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Bloomfield 1000 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Bloomfield 1000, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Bloomfield 1000.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Bloomfield 1000. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Bloomfield 1000 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.