Ventless Hood System MODEL FH-28 Installation & Operation Manual Serial Numbers 123046 and higher.
Warranty Information LIMITED ONE YEAR WARRANTY BKI (The "Company") warrants to the origin al purc haser that at time of shipment from the Company factory, this equipment will be free from defect in materials and workmanship.
Ventless Hood System Table of Contents 1 T able of Content s Table of Contents .............................................................................................................. .......................... 1 Introduc tion ..................
Ventless Hood System Introduction 2 Introduction Congratulations! You have cho sen BKI ’s Ventless Ho od syste m, a state-of-t he-a rt unit that filters g rease laden air and returns it to the room.
Ventless Hood System Introduction 3 Specific Precautions Carbon monoxide poisoning will result from usin g this hood with a ny appliance that utilizes combustible fuel.
Ventless Hood System Introduction 4 Keep Safety Labels Clean and in Good Condition Do not remove or cover any safety labels on your e quipment. Keep all safety labels clean and in good con dition. Replace any damaged or missing safety labels. If you need new safety labels, contact: BKI Technical Services Depart ment P.
Ventless Hood System Introduction 5 UL Information Failure to adhere to building, fire and electri cal co de s during installation of this unit could result in death, serio us inju ry or property damage.
Ventless Hood System Introduction 6 Fryers Specifications Volts 208/240 Phase 1 or 3 Maximum Amps 60 Maximum Input 22 KW (3ph) 14.4 KW (1ph) Frequency 60 Hz Maximum normal frying temperature 375 ° F. (191 ° C.) Maximum shortening capacity 110 lbs. (50kg.
Ventless Hood System Operation 7 Operation Principle of Operation A blower inside the ventless hood d raws cooking vap ors through a grease baffle. Inside the b affle, the air reverses direction two times capturing p article s of moisture, grease, and dirt.
Ventless Hood System Operation 8 Shut-Down Power to the appliance is turned off, when the hood is turned off. For proper operation, alwa ys turn off ap pliance and allow time for it to cool before turning off the filter hood. This will in sure proper capture of gre ase vapors.
Ventless Hood System Installation 9 Inst allation Unpacking and Handling Inspection for Sh ipping Damage YOU are responsible for filing all freight claim s with th e delivering truck line. Insp ect all cartons and crate s for damage as soon as they arrive.
Ventless Hood System Installation 10 Leveling 1. Adjust the four feet provided on the bottom of the unit so there is a minimum of 6” clearance below the frame side members (NSF/UL REQUI REMENTS). 2. Check for level from side to side and front to back u si ng a 4’ level placed appropriately on the frame.
Ventless Hood System Installation 11 Securing Wall Mount After the hood has been located and lev eled, secure to building by utilizing the .4 37 diameter holes provided in the rear of the fire extinguisher cylinder sh elf (Refer to figure below).
Ventless Hood System Installation 12 Assembly and Mounting Fire Damper A UL Listed 165 ° F fusible link must be installed in the dampe r assembly locate d at the top of the unit. Install as follows: 1. Lift the damper. 2. Place the link on the damper hook.
Ventless Hood System Installation 13 Particle/Odor Filter 1. Remove the filter from the plastic bag. 2. Open the filter door on the front of the unit by rotating the handle counter-clockwise. 3. Observing the “UP” arrows on the filter, with a hand at each front corne r, carefully slide the filter into the unit.
Ventless Hood System Installation 14 Appliance Restraining Device Install appliance-restraining device as shown in the figure bel ow. In the event of an appliance fire, seriou s injury, property damage or death could occur if the appliance is not secu red to t he hood.
Ventless Hood System Installation 15 Fire Extinguishi ng Sy stem In the event of an appliance fire, seriou s injury, property damage or death could occur if any part of the appliance obstructs the spray n ozzles. Ensure that lids and/or other parts of the appliance do n o t obstruct the spray pattern of either nozzle.
Ventless Hood System Installation 16 3. If required, connect the provided fire extingui shing system contacts for remote signaling (refe r to the electrical diagram in this manual). 4. Adjust the position of the two ADP appliance nozzl es as depicted b elow.
Ventless Hood System Installation 17 The fire extinguishing system must be o perative before the electrical system will function. Refer to the electrical diagram included i n attached to this unit or in the servi ce manual.
Ventless Hood System Installation 18.
Ventless Hood System Installation 19 Appliance Electrical Connection This connection is for ap pli ances requiring a UL listed flexible conduit connections (refer to figure below). 1. Remove receptacle and fo ur wires (T1, T2, T3, and Grou nd). 2. Cover junction box hole with provided pl ate and hardware removed from re ceptacle.
Ventless Hood System Maintenance 20 Maintenance Electrocution could occur if this unit is hosed d own wit h water. This unit is NOT designed for hose wash -d own cleaning! Refer to sch eduled maintenance b elow for proper hood cleaning. Electrocution could occur if powe r is not removed from this unit before servicing.
Ventless Hood System Maintenance 21 Cleaning the Grease Baffle 1. Shut down the unit. 2. Locate the thumbscrews and retaining fr ame at the top of the grea se baffle. 3. With one hand, hold the baffle to prevent it from dropping. With the other hand, lo ose n the thumbscrews and slide the retaining frame forward.
P.O. Box 80400, Simpsonvill e, S.C. 29680-0400, USA http://www.bkideas.co m Made and printed in t he U.S.A LI0114/0 407.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté BKI Ventless Hood System FH-28 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du BKI Ventless Hood System FH-28 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation BKI Ventless Hood System FH-28, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le BKI Ventless Hood System FH-28 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le BKI Ventless Hood System FH-28, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du BKI Ventless Hood System FH-28.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le BKI Ventless Hood System FH-28. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei BKI Ventless Hood System FH-28 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.