Use, Care, and Installation Guide www .zephyronline.com Model number: Serial Number: Date of Purchase: Sales Dealer: JUL1 1.0601 © 2010 Zephyr Corporation T ornado II AK8200AS T ornado III AK8300ASX .
www .zephyronline.com.
1 SAFETY NOTICE ................................................................. 2-3 LIST OF MA TERIALS ....................................................... 4 INST ALLA TION Ducting Calculation Sheet ....................................... 5 Mounting Height & Clearance .
Important Safety Notice READ AND SA VE THESE INSTRUCTIONS 2 www .zephyronline.com W ARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS F AN WITH ANY SOLID-ST A TE CONTROL DEVICE. W ARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSER VE THE FOLLOWING: a.
Important Safety Notice 3 W ARNING TO REDUCE THE RISK OF FIRE, USE ONL Y MET AL DUCTWORK. NOT FOR USE OVER AN OUTDOOR GRILL CAUTION T o reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages.
List of Materials 4 www .zephyronline.com MODELS: AK8200AS AND AK8300ASX P ARTS SUPPLIED AK8200AS AK8300ASX 1 - Power Pack 1 - Power Pack 2 - Baffl e fi lters 3 - Baffl e fi lters 2 - Halogen ligh.
5 Installation – Ducting Calculation Sheet Duct pieces To t a l Equivalent number length x used = 3-1/ 4” x 10” Rect., straight 1 Ft . x ( ) = Ft. 7”-10” Round, straight 1 Ft . x ( ) = Ft. 3-1/ 4” x 10” Rect. 9 0 0 elb ow 15 Ft . x ( ) = Ft.
Installation – Mounting Height & Clearance 6 www .zephyronline.com DUCTING A minimum of 6” round or 3-1/4” x 10” rectangular duct must be used to maintain maximum air fl ow effi ciency for single blower and 8” round duct for dual and remote blowers.
7 W ARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only . Fasten all connections with sheet metal screws and tape all joints with certifi ed Silver T ape or Duct T ape.
8 www .zephyronline.com Installation – Specifi cations C L 11 7/16 ” 13/16” 2 5/8 ” 14 1 1/16 ” 15 13/16 ” 2 3/8 ” 14 3/4 ” 24 5/8 ” 25 15/16 ” 29 13/16 ” 4 3/4 ” 11 7/16 ” 1 5/16 ” 6 1/2 ” 1 1/2 ” C L elec.
9 ELECTRICAL W ARNING All Electrical work must be performed by qualifi ed electrician or person with similar technical know how and background. For personal safety , remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance.
10 www .zephyronline.com Installation – Installing the Power Pack 1. Install blower into Power Pack AK8200AS - Blower is pre-installed AK8300ASX - Refer to page 1 1 for instructions Remove support screw from top of Power Pack before installing into cabinet.
11 MUL TIPLE BLOWERS ARE COMP A TIBLE WITH AK8300ASX ONL Y . AK8200AS INCLUDES A 1000 CFM DUAL BLOWER ONL Y . FOR REMOTE BLOWER PREP ARA TION INSTRUCTIONS TURN TO P AGE 12. 1. Position blower plate over bracket on inside back of hood and pivot up. Secure plate to hood with (2) 10x3/16” screws.
12 www .zephyronline.com Installation – Remote Blower Preparation 1. Place 8” round adapter on top of power pack and secure with (4) M4x8 screws. Connect 8” round duct work to 8” round adapter . 2. Install threaded end of remote blower wiring through external blower wiring knock out (B) located in junction box on top of power pack.
13 F The standard baffle filters are required to be cleaned frequently and as recommended in order to maintain blower efficiency . If improperly maintained, residue from cooking will sift through filters and cause damage to hood blowers and other sensitive components; and possible clog duct work and create a fire hazard.
Features & Controls – T ouch Controls 14 www .zephyronline.com B a ffl e Filt er Cl ean R em i n d er Whether your hood is installed as an exhaust or purifying unit, a set if baffle filters are fitted by the factory , These baffle filters are intended to filter out residue from cooking.
15 FCC Caution: T o assure continued compliance, any changes or modifi cations not expressly approved by the party responsible for compliance could void the user ’s authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer or peripheral device.
Maintenance – Cleaning and Installing Filters 16 www .zephyronline.com SURF ACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/ scoring pads which will scratch and damage surface.
17 REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. T ouching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise.
T roubleshooting 18 www .zephyronline.com TROUBLESHOOTING PROCEDURES FOR TORNADO II AND TORNADO III Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON.
19 DESCRIPTION P ART # Replacement Parts Light Bulb MR16 (GU10) 35W (each) Z0B-0023 Baffl e Filter (each) 50210010 Remote Control 14000005 Optional Accessories Liner ,36” (AK8200AS) AK0806AS Liner .
1-888-880-8368 STAPLE YOUR RECEIPT HERE TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: Zephyr Corporation (referred to herein as “we” or “us”) warrants to .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Zephyr AK8200AS c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Zephyr AK8200AS - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Zephyr AK8200AS, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Zephyr AK8200AS va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Zephyr AK8200AS, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Zephyr AK8200AS.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Zephyr AK8200AS. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Zephyr AK8200AS ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.