TRANSI TION CMY Fiber Optic Illuminator CMY with TW -White light with WT -White light Transition User Manual.
2 Table of Contents Declaration of Conformity………………………………………………..3 Safety Notice………………………………………………………………4 Introducti.
3.
4 Safety Notice SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS This manual gives step-by-step instructions for preparation, setup, and operation of the Transition TM Fiber Illuminator. There is a potential risk of fire, electric shock or injury to persons if the product is not used as instructed.
5.
6 Intro to the Transition.
7 Transition Product Introduction Wybron is pleased to announce the introduction of the Transition fiber illuminator. Contained within a small easy to integrate package and ultra bright fiber optic illuminator, the Transition brings quality and durability to your venue.
8 Transition Quick Start Configuration 1. Connect the Equipment a) Connect fiber bundle common end to the Transition output port. b) Connect the Transition to a DMX source with a 5-pin cable c) Connect to AC power (110 – 240 VAC 50/60Hz) 2.
9 Transition Specifications Model 8670: Transition CMY Fiber Illuminator Features: No lamp optimization required Rubber feet for cabinet or countertop installation Durable all metal construction Output supports fiber bundles ranging from 17 – 30 mm dia.
10 Fixture Setup and Configuration Installing the Lamp DANGER: Disconnect fixture from line voltage before replacing lamp. CAUTION: Lamp and lamp mounting surfaces are hot! Allow lamp to cool 10 minut.
11 Maximum ambient temperature (t a ) may not exceed 40˚C (104˚F) Keep objects at least 2” (50mm) from sides of the fixture. Keep objects at least 6” from the top of the fixture. Cabinet or Closet Mounting The Transition may be mounted in a closet or cabinet on a hard surface such as wood, laminate, or metal.
12 DMX / RDM Setup and Operation Controls and Indicators Transition controls and indicators as follows: o A three character seven-segment display o 4 push buttons: Menu , ( + ), ( - ), and Enter o Power (red) and signal (green) indicator LED’s The seven-segment display shows the address number (1-508) and the Demo mode (OFF, d1, d2).
13 Display Messages Normal Messages 680 Displayed for 1 second after power is applied. This is the RDM manufacturer device identification number Ini Indicates that the unit is initializing the diachronic filters 001 – 508 The first DMX address Transition will respond to.
14 EEP Err An attempt to write to non-volatile memory failed. The unit will continue to respond to commands. SEr Err The RDM unique ID has been corrupted. The unit will operate normally but should not be used in an RDM environment. Contact dealer or factory for assistance.
15 Service Lamp Replacement DANGER: Disconnect fixture from line voltage before replacing lamp. WARNING: Lamp and lamp mounting surfaces are hot! Allow lamp to cool before replacing. Disconnect fixture from AC power. Remove lamp plate by removing mounting screws as shown in figure 1.
16 Cleaning the Color Filters It is recommended that the color filters be only cleaned with low-pressure air without disassembling the color filters from the motor shafts. If the color module must be disassembled to clean the dichroic filters take careful note of the location and offset height of the individual color flags.
17 Flash Reprogramming Transition firmware can be updated as new firmware versions become available through the DMX/RDM port using an Infogate gateway and the Infogate application.
18 Warranty Information WYBRON, INC. warrants to the original owner or retail customer that for a period of one year from date of delivery of a portable system or energization of a permanently install.
19 Figure 2.1 Figure .2.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Wybron Transition Optic c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Wybron Transition Optic - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Wybron Transition Optic, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Wybron Transition Optic va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Wybron Transition Optic, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Wybron Transition Optic.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Wybron Transition Optic. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Wybron Transition Optic ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.