MODEL: ADM8 10080170 Operating Instructions CARPET EXTRACTOR Read these instructions bef ore operating the machine RR 86038320 03/16/07 PRV NO. 98628.
MACHINE DATA LOG/OVERVIEW ADMIRAL 86038230 03/16/07 MODEL _____________________________________ __ DATE OF PURCHASE __________________________ SERIAL NUMBER ______________________________ SALES REPRES.
TABLE OF CONTENTS ADMIRAL 86038230 03/16/07 2 Machine Data Log/ Overview . ............................... 1 Table of Co ntents ................................................. 2 HOW TO USE THIS MANUAL How to use this Manual. ........................
HOW TO USE THIS MANUAL ADMIRAL 86038230 03/16/07 This manual contains the f ollowing sections: - HOW TO USE THIS MANUAL - SAFETY - OPERATIONS - MAINTENANCE - PARTS LIST The HOW TO USE THIS MANUAL section will tell you how to find important information for ordering correct repair parts.
SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precaution must always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. This machine is for commercial use. To reduce the risk of fire, electric shock, or injury: Connect to a properly grounded outlet .
HAZARD INTENSITY LEVEL ADMIRAL 86038230 03/16/07 2-2 The following symbols are used throughout this guide as indicated in their descriptions: HAZARD INTENSITY LEVEL There are three levels of hazard in tensity identified by signal words - WARNI NG and CAUTION and FOR SAFETY.
GROUNDING INSTRUCTIONS THIS PRODUCT IS FOR COMMERCIAL USE ONLY. NOTE: In Can ada, th e use of a temp orary adaptor is no t p ermit te d by the Canadia n Electri cal Co de PROPER GR OUNDI NG Meta l Sc r e w A daptor Grounded Out let Box Fig. A Fig. B Fig.
TECHNICAL SPECIFICATIONS POWER TYPE ELECTRICAL: 115 V, 15 A, 60 HZ ELECTRIC VACUUM MOTOR: (1) –3 stage, 1 hp, 99 cfm (2.80 cubic meters/min.) Waterlift –117 ” (297 cm) BRUSH: (1) 15” (38.1 cm.) SOLUTION PUMP: 100 PSI, diaphragm style, internal bypass SOLUTION CAPACITY: 8 gallon s (3 0.
CONTROLS/COMPONENT LOCATIONS 1. Main Handle. Used to pull and maneuver machine. 2. Handle Adjustment. Used to adjust height of handle. 3. Electrical Cord. 4. Solution Switch. Turns on pump. Continuous position (bottom) activates electro-valve to dispense solution to floor through jets.
CONTROLS/COMPONENT LOCATIONS 1. Solution Accessory Tool Hookup. Used for various auxiliary cleaning t ools. 2. Vacuum Hose Door. Used to connect various auxiliary 1 ½ inch cleaning tool vacuum hoses. 3. Brush Height Adjustment. Used to regulate brush height from storage positio n to variou s carpet heights.
CONTROLS/COMPONENT LOCATIONS 1. Solution Intake Cover. 2. Vacuum Intake Cover. 3. Float Shut-Off. 4. Clean-Out Opening. 5. Pour Spout. 6. Lift Handle. 6 1 2 4 3 5 6 ADMIRAL 86038230 03/16/07 3-4.
FILLING OPERATIONS RECOVERY TANK SOLUTION TANK STEP 1 Remove recover y tank 140°F ( 60°C ) 8 gal. ( 30.3 ltr. ) A dd water or STEP 2 FILLING THE ADMIRAL FILL LINE STEP 3 A dd cleaning chemical 8 – 16oz.
OPERATIONS Remove electrical co rd an d literature from recovery tank. Fill solution tank (see filling instructions page 3-5). STEP 1 Adjust brush to proper setting. Note: For good operation the brush must skim the carpet. If circuit breaker trips raise brush to p revent damage to m otor or ca rpet.
OPERATIONS STEP 5 Adjust handle to comfortable operating position. Tip machine back by main handle to move to starting point. Lower machine to floor. STEP 6 Select contin uou s setting to st art solution spray or select intermittent setting to enable use of trigger switches to sta rt solution spra y.
CLEANING PROCEDURE Start at wall closest to power outlet. Pull straight back without pushi ng do wn on handle. STEP 1 Release intermittent trigger switches or turn off continuous setting on sol ution switch approximately 1 foot before en ding cleaning pass.
CLEANING PROCEDURE To speed drying, use a Windblo wer ™ fan. Empty recovery tank by releasing dum p hose. Use a hose with cold water to clean out the recovery tank. Also drain solution tank after each use. STEP 7 STEP 8 After cleaning, turn off all controls, return brush to storage position a nd ca refully unplug machine.
ACCESSORY TOOL USAGE ADMIRAL 86038230 03/16/07 3-10 APRV NO. Turn on vacuum motor swit ch and set solution switch to intermittent position. Note: Be sure brush switch is in off position and brush is in storage position. Squeeze handle on accessory tool to begin cleaning.
MAINTENANCE SERVICE SCHEDULE MAINTENANCE DAILY WEEKLY QUARTERLY Check machine for cord damage * Check recovery dome an d gasket for damage and cleanliness * Check brush – sho uld be clean with no lint or strings attached * Inspect vac shoe for blockage; remove fibers with coat hanger, etc.
MAINTENANCE PERIODIC MAINTENANCE Twice a month, flush a white vinegar sol ution (One quart vinegar to two gallons of water) or anti- browning solution (mixed as directe d) through the extractor. This will prev ent build-up of alkaline residue in the system.
MAINTENANCE ONLY QUALIFIED MAINTENANCE PE RSONNEL ARE TO PERFORM THE FOLLOWING REPAIRS. ! WARNING: VACUUM MOTOR REPLACEMENT 1. Turn off all switches and unplug machin e. 2. Remove recovery tank. 3. Remove the (2) screws that fasten the solution tank to the frame, and tilt tank bac k to expose the inside of the frame.
MAINTENANCE ADMIRAL 86038230 03/16/07 4-4 ONLY QUALIFIED MAINTENANCE PE RSONNEL ARE TO PERFORM THE FOLLOWING REPAIRS. WARNING: ! BELT REPLACEMENT 86249420 PRV NO. 62759 1. Turn off all switches and unplug machine. 2. Remove recovery tank and brush. 3.
MAINTENANCE ADMIRAL 86038230 03/16/07 4- ARNING: 5 ! W ` SOLUTION PUMP REPLACEMENT ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORM THE FOLLOWING REPAIRS.
WIRING DIAGRAM 86238820 PRV NO. 41 351 86268290 PRV NO. 88229 86268460 PRV NO. 88333 86268430 PRV NO. 88323 86238840 PRV NO. 41356 8638830 PRV NO. 41355 86266890 PRV NO.
TROUBLESHOOTING CHART PROBLEM CAUSE SOLUTION Is the cord plugged in. Plug in cord. Circuit breaker tripped in building. Reset breaker. Faulty switch. Call for service. No Power, Nothing Runs Faulty power cord or pigtail. Call for service. Vacuum circuit breaker tripped.
NOTES: ADMIRAL 86038230 03/16/07 4-8.
FRAME ASSEMBLY ADMIRAL 86038230 03/16/07 5-1 2 16 27 29 20 8 5 22 11 10 15 7 13 14 24 25 4 3 26 34 21 18 19 A 12 33 9 6 B 30 31 32 C 28 (SEE PG. 5-9) (SEE PG.
FRAME ASSEMBLY ADMIRAL 86038230 03/16/07 5- 2 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 OPEN - - 2 86003620 34341 1 FRAME, CLP FAMILY 3 86004340 39528 1 HOSE ASM, 1.
BRUSH ASSEMBLY ADMIRAL 86038230 03/16/07 5-3 25 9 3 2 46 5 17 23 36 17 34 45 47 44 25 20 29 30 13 43 33 32 1 14 16 26 15 18 24 30 30 11 25 29 25 7 16 31 10 21 22 40 35 28 42 3 6 19 37 41 27 4 26 12 38.
BRUSH ASSEMBLY ADMIRAL 86038230 03/16/07 5- 4 REF PART NO. PART NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86000730 03110 1 AXLE, ROLLER 2 86227100 0408 4 1 ADAPTER, BRUSH BRG. 3 86000900 09019 2 BEARING, 1.125ODX.500IDX.375 4 86001100 11045 1 BELT, 180J6 MICRO-V 5 86001140 1251 4 1 BRUSH, 15L X 3.
PUMP ASSEMBLY ADMIRAL 86038230 03/16/07 5-5 3 4 13 10 16 6 5 11 15 19 18 1 20 7 16 8 21 17 9 2 14 12 25 26 23 28 24 26 D 20 (SEE PG. 5-11) 27.
PUMP ASSEMBLY ADMIRAL 86038230 03/16/07 5- 6 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86002470 22072 1 COUPLING, 1/4 ANCHOR W/1" HEX 2 86002480 22090 2 CONNECTOR, 1/8FPT X 1/.
VACUUM SHOE ASSEMBLY ADMIRAL 86038230 03/16/07 5-7 4 7 13 3 10 7 5 6 11 8 2 1 12 11.
VACUUM SHOE ASSEMBLY ADMIRAL 86038230 03/16/07 5- 8 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86227350 05016 4 ARM, VAC SHOE PARALLEL 2 86234760 27674 1 COVER, ACCESSORY PORT 3 86005810 57245 4 NUT, 1/4-20 HEX NYLOCK SS 4 86006790 70351 2 SCR, 10-32 X 3/8 HHTR W/STAR 5 86275120 70360 4 SCR, 1/4-20 X.
CONTROL PANEL ASSEMBLY ADMIRAL 86038230 03/16/07 5-9 13 17 6 12 4 10 15 5 14 16 20 7 1 19 18 11 8 3 9 2 36 33 32 31 30 29 28 27 26 25 24 23 22 21 35 34 C (SEE PG.
CONTROL PANEL ASSEMBLY ADMIRAL 86038230 03/16/07 5-1 0 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86001240 14020 1 TERMINAL BLOCK, 115V (3-4-3) 2 86001980 14700 1 BREAKER, 15A 250VA.
SOLUTION TANK ASSEMBLY ADMIRAL 86038230 03/16/07 5-11 6 14* 27 16 5* 4 2 8 24* 17* 11 15 20 12B 7 3 13 16 10 1 9 19 18 A B D 7* (SEE PG. 5-1) (SEE PG. 5-5 ) 22* 21* 23* 18 26 25 28 16 27 29 30 31 32 12A 12 (SEE PG.
SOLUTION TANK ASSEMBLY ADMIRAL 86038230 03/16/07 5-1 2 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86233140 20041 2 CLAMP, 2.0" WORM GEAR 2 86233150 20042 1 CLAMP, 3/8 HOSE (D-S.
RECOVERY TANK ASSEMBLY ADMIRAL 86038230 03/16/07 5-13 16 11 7 E 9 2 6 17 13 8 4 15 5 12 E 18 10 1 14 12 3 1B 10B 11B 14B 12.
RECOVERY TANK ASSEMBLY ADMIRAL 86038230 03/16/07 5-1 4 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1A 86002400 20064 1 CLAMP, 2.0" WORM GEAR X .312 1000083447 1B 86002350 20002 1 CLAMP, 2.0” NYLON RATCHET 2 86233140 20041 1 CLAMP, 2.
SUGGESTED SPARE PARTS ADMIRAL 86038230 03/16/07 5-15 PART NO. PRV NO. DESCRIPTION SERIAL NO. FROM NOTES: 86001140 1251 4 BRUSH, 15L X 3.38OD WAS 12031 86001100 11045 BELT, 180J6 MICRO-V 86000900 09019 BEARING, 1.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Windsor 10080170 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Windsor 10080170 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Windsor 10080170, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Windsor 10080170 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Windsor 10080170, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Windsor 10080170.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Windsor 10080170. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Windsor 10080170 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.