@ WHITE-RODGERS 1F85-277 Heating & Air Conditioning 7 Day/5-1-1 Programmable/Non-programmable, Auto Changeover, Multi-Stage/Heat Pump Thermostat INSTALLATION INSTRUCTIONS FAILURE TO READ AND FOLLOWALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURYAND/OR PROPERTY DAMAGE.
MOUNTING AND WIRING Do not use on circuits exceeding specified voltage. Higher voltage will damage control and could cause shock or fire hazard. Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring will damage thermostat and could cause personal injury and/or property damage.
WIRING DIAGRAMS = I Polarity must be observed, tf the HOT side of the second transformer is jumpered to the COMMON side of the first transformer a short will be made, Damage to equ pment w occur when power s restored, E/W1 SYSTE 2t .
Multi-Stage Terminal Outputs Refer to equipment manufacturers' instructions for specific system wiring information. You can configure the thermostat for use with either multi-stage electric heat systems or multi-stage gas systems. When con- figured for electric heat, the G terminal (blower/fan) will be energized on a call for heat.
Before you begin programming your thermostat, you should be familiar with its features and with the display and the location andoperation of the thermostat buttons. Your thermostat consists oftwo parts: the thermostat cover and the base. To remove the cover, pull itstraight out from the base.
CONFIGURATION MENU Press the SYSTEM button until OFF is displayed, then press the (_ and (_ simultaneously INSTALLER/CONFIGURATION MENU Press Displayed Press Q or Q Step Button(s) (Factory Default) to.
5) Select Energy Management Recovery OFF or ON - Energy Management Recovery (EMR) causes the thermo- stat to start heating or cooling early to make the building temperature reach the program setpoint at the time you specify. Heating will start 5 minutes early for every 1 ° of temperature required to reach setpoint.
SPECIFICATIONS ELECTRICAL DATA Electrical Rating: 20 to 30 VAC 50/60 Hz or DC 0.05 to 1.5 Amps (Load per terminal) 2.5 Amps Maximum Total Load (All terminals combined) TH E RMAL DATA Setpoint Temperat.
PROGRAMMING YOURTHERMOSTAT This section will help you plan your thermostat's program to meet your needs. For maximum comfort and efficiency, keep the following guidelines in mind when planning your program.
OPERATION heating program period appears. The time will change in 15- minute increments. When your selected time is displayed, press TIME again to return to the change temperature mode. 5. Press PRGM once. The currently programmed start time and setpoint temperature for the Monday's 2nd heating program period will appear.
TROUBLESHOOTING Symptom No Heat (continued) No Cool Heat, Cool or Fan Runs Constantly Possible Cause Furnace (Air Conditioner) Cycles Too Fast or Too Slow (narrow or wide temperature swing) 5. Heating system requires service or thermostat requires replacement.
TROUBLESHOOTING Symptom Forgot Keypad Lockout Code (continued) Why won't my 2nd or 3rd stage come on? Possible Cause First stage is keeping up with demand. Corrective Action (Z) and (_ and SYSTEM button at the same time to reset the lockout code, unlock the keypad and reset all configuration menu settings.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté White Rodgers 1F85-277 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du White Rodgers 1F85-277 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation White Rodgers 1F85-277, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le White Rodgers 1F85-277 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le White Rodgers 1F85-277, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du White Rodgers 1F85-277.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le White Rodgers 1F85-277. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei White Rodgers 1F85-277 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.