Manuel d'utilisation / d'entretien du produit 2GR65CF ML-136432 du fabricant Vulcan-Hart
Aller à la page of 27
INSTALLATION & OPERATIONAL MANUAL GRD & GRC SERIES GAS FRYERS With KleenScreen PLUS ® Filtration Systems M O D E L S : 1 G R 4 5 D M L - 1 3 6 4 1 1 1 G R 4 5 C M L - 1 3 6 4 1 4 1 G R 6 5 D .
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -2- IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -3- TABLE OF CONTENTS IMPORTANT FOR YOUR SAFETY……………………………… ……….
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -4- INTRODUCTION GENERAL Vulcan Fryers are produced wit h quality workmanship and mate rial. Proper installation, usage and maintenance will result in year s of satisfactory performance.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -5- INSTALLATION Do not use the door or its handle to lift the fryer. Before installing the fryer, veri fy that the type of gas (natural or propane) agrees with the specifications on the fryer data plate, which is located on the inside of the door panel.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -6- CODES AND STANDARDS The fryer must be insta lled in accordance with: In the United States: State and local codes, or in t he absence of local codes, with: National Fuel Gas Code, ANSI-Z223.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -7- FLUE CONNECTION Make the flue connection as follows: Comply with Vapor Removal from Cooking Equipment , ANSI-NFPA Standard #96 (latest edition), available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -8- After piping has been checked for leaks, fully purge gas pipes to remove air. GAS PRESSURES (ALL MODELS): The gas pressure should be set at 4” W.C. (W ater Column) (0.8 kPa) for natural gas and 10” W.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -9- In Australia, use only the caster suppl ied by the manufacturer for the fryer device. The fryer must be installed using a hose assembly restraining device to limit the movement of the appliance in accordance with AS1869.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -10- BEFORE FIRST USE Cleaning New units are wiped down at the fa ctory to remove an y visible signs of dirt, oil, grease, etc.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -11- BASIC FRYING INSTRUCTION Set the desired temperature and allow short ening to heat up to that temperature. Fry items that are the same size to ensure equal doneness. Drain or wipe dry raw or wet foods to minimize splatter when lowering into hot shortening.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -12- TURNING ON THE FRYER Open the door to the fryer. Turn the power switch to the on position. Set temperature by turning the knob to the desired temperat ures. The burners will light automatically.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -13- Programming the Solid State Control.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -14- Programming the Computer Control.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -15- DRAINING THE TANK 1. Turn off fryer. 2. Insert the drain extension into t he drain valve. Tighten only hand tight. 3. Direct the drain spout into the container that you want to drai n the shortening into.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -16- 7. Press the TEMP button again and the gas burners will heat the solution. Bring the solution to a simmer only. A llow to stand for a few minutes. 8. Turn OFF the power to the fryer.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -17- KleenScreen Plus ® Filtration System Installation and Operational Manual for “DF” and “CF” Models GRD/CF 2GR45DF S.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -18- Filtering Instructions for KleenScreen PLUS ® Fryers General The KleenScreen PLUS ® filtration system filters t he oil as it is pumped back into its’ respective tank(s). Only one tank can be dr ained and filtered at a time.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -19- Fully assembled filter screen assembly: F i g . 2 Secure Tube with Suction Tube Clip Filter Screen Lays Flat On Bottom of Filter Pan Fig.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -20- INSTRUCTIONS TO REMOVE & REPLACE KLEENSCREEN PLUS ® FILTER ENVELOPE FOR ABSOLUTE FILTRATION & MAXIMUM FLOW RA TE WE RECOMME ND YOU CHANGE YOUR FILTER ENVELOPES AT EVERY OIL CHANGE (10-14 DAYS DEPENDING ON OIL USAGE).
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -21- Operation Hot oil and parts can cause burns. Use care when operating, cleaning and servicing the fryer. Spilling hot frying compound can cause severe burns. Do not move fryer without draining all frying compound from the tank.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -22- Filtering Instructions for KleenScreen PLUS ® Fryers with Solid State Controls.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -23- Filtering Instructions for KleenScreen PLUS ® Fryers with Computer Controls.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -24- FILTERING TIP: Open the filtering drawer approximately 1” to allow any oil in the re turn line to run back into the filter pan. This will take about 30 seconds to complete.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -25- BOIL OUT PROCEDURE: Use the Boil Out By-Pass™ drai n extension allowing the boil out solution to exit the fry tank without using the filtering system. Do not allow water to run through the motor / pump.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -26- MAINTENANCE Hot oil and hot parts can cause burns. Use care when operating, cleani ng, and servicing the fry er. Spilling hot fryer com pound can cause severe burns. Do not move fryer without draining all frying com pound from the tank.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-329 33 Rev. J (August 2012) -27- OPEN PROBE – If an open probe is detected, the heat demand is disabled and any running cooking cycles are cancelled.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Vulcan-Hart 2GR65CF ML-136432 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Vulcan-Hart 2GR65CF ML-136432 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Vulcan-Hart 2GR65CF ML-136432, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Vulcan-Hart 2GR65CF ML-136432 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Vulcan-Hart 2GR65CF ML-136432, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Vulcan-Hart 2GR65CF ML-136432.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Vulcan-Hart 2GR65CF ML-136432. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Vulcan-Hart 2GR65CF ML-136432 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.