INSTALLATION & OPERATIONAL MANUAL GRM SERIES GAS FRYERS MODELS: 1GR35M ML-136407 1GR45M ML-136408 1GR65M ML-136409 1GR85M ML-136410 1GR45MF ML-136785 1GR65MF ML-136786 1GR85MF ML-136787 2GR45MF ML.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -2- IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -3- TABLE OF CONTENTS IMPORTANT FOR YOUR SAFETY……………………………… ……….
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -4- INTRODUCTION GENERAL Vulcan Fryers are produced wit h quality workmanship and mate rial. Proper installation, usage and maintenance will result in year s of satisfactory performance.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -5- Check that the followi ng have been included: Crumb Rack Basket Hanger Twin Fry Baskets (2) Tank Brush Adjustable Casters (4) two locking, two non- locking for freestanding fryers.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -6- Minimum clearance from noncombustible construction: 0” from the sides of the fryer 0” from the back of the fryer Between the fryer and any open-top flame units: 16” (41 cm) Allow space for servicing and operation.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -7- ASSEMBLY The fryer must be restrained to prevent tipping and the splashing of ho t liquid. The means of restraint may be the manner of installa tion, such as connection to a battery of appliances, installing the fryer in an alcove, or by separate m eans such as adequate ties.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -8- Prior to lighting, check all joints in the g as supply line for lea ks. Use soap and water solution. Do not use an open flame. After piping has been checked for leaks, fully purge gas pipes to remove air.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -9- The fryer must be installed with a connec tor (not supplied by Vulcan) complying with the above codes. The fryer must be installed with restrain ing means to guard against transmission of strain to the connector.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -10- BEFORE FIRST USE Cleaning New units are wiped down at the fa ctory to remove an y visible signs of dirt, oil, grease, etc.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -11- LIGHTING THE PILOT A B A Thermostat Knob B G a s C o n t r o l H a n d l e 1. Open the door. 2. Turn the thermostat to OFF (see figure below, view A). The thermostat is located behind the door.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -12- TURNING ON THE FRYER Set the temperature knob to desired temperature. After the set temperature has been reached, the thermostat shuts off the gas flow to burners. The pilot remains lit.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -13- When frying doughnuts and fritters, turn product only once during frying. When cooking French fries or onion rings, shake the basket several times. Batter-covered foods should be dropped carefully, one by one, into shortening or basket.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -14- 5. Slowly open the drain valve to allow oil to fl ow from the fry tank to the filter pan. Then open the drain valve all the way. 6. When fry tank is empty use the tank brush to remove any additional debris.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -15- Use a damp cloth with warm water and a mild soap or detergent. Do not use chlorine or sulfate/sulfide cleaners.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -16- KleenScreen PLUS ® Filtration System Installation and Operational Manual For GRMF Models 2GR45MF Shown GAS KleenScreen PLUS® Mo.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -17- Filtering Instructions for KleenScreen PLUS ® Fryers General The KleenScreen PLUS® filtration system filters the oil as it is pumped back into its’ respective tank(s). Only one tank can be dr ained and filtered at a time.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -18- Fully assembled filter screen assembly: F i g . 2 Secure Tube with Suction Tube Clip Filter Screen Lays Flat On Bottom of Filter Pan Fig.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -19- INSTRUCTIONS TO REMOVE & REPLACE KLEENSCREEN PLUS ® FILTER ENVELOPE FOR ABSOLUTE FILTRATION & MAXIMUM FLOW RA TE WE RECOMME ND YOU CHANGE YOUR FILTER ENVELOPES AT EVERY OIL CHANGE (10-14 DAYS DEPENDING ON OIL USAGE).
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -20- Operation Hot oil and parts can cause burns. Use care when operating, cleaning and servicing the fryer. Spilling hot frying compound can cause severe burns. Do not move fryer without draining all frying compound from the tank.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -21- 4. Drain the oil out of t he fry tank by turning t he red handle drain valve. The filter pan will begin to fill with oil. When the oil level fills half of the filter pan, pull the red handled filter lever towards you.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -22- FLUSH AND DISCARD: 1. Follow filtering instructions 1- 3, however do not put oil treatment media into the fryer. Drain the fryer oil into the filter pan. 2. Attach the quick disconnect hose to the discard male quick di sconnect fitting.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -23- THERMAL OVERLOAD PROTECTION BUTTON: The motor/pump supplied wi th the filtering system has a thermal overload protec tion circuit that senses when excess heat occurs due to filtering for long periods of time or under heavy load prior to discarding debris buildup.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -24- Troubleshooting Chart: Problem: Probable Cause: No Heat: Thermostat dial not turned on.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Vulcan-Hart 1GR45M ML-136408 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Vulcan-Hart 1GR45M ML-136408 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Vulcan-Hart 1GR45M ML-136408, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Vulcan-Hart 1GR45M ML-136408 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Vulcan-Hart 1GR45M ML-136408, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Vulcan-Hart 1GR45M ML-136408.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Vulcan-Hart 1GR45M ML-136408. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Vulcan-Hart 1GR45M ML-136408 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.