Manuel d'utilisation / d'entretien du produit SR36A du fabricant Vermont Casting
Aller à la page of 24
SR/SC Series "A" W oodburning Fireplace For Models: SR36A SR42A SC36A SC42A For use in U.S./Canada Underwriter's Laboratories Report No. MH6018 DO NOT DISCARD THIS MANUAL: Retain for future use. 948 SR cover 1 1/18/97 948 SC cover 1 1/18/97 7412948 12/06 Rev .
2 SR/SC Series "A" W oodb ur ning Fireplace 7412948 Safety Information PLEASE READ THIS MANUAL BEFORE INST ALLING AND USING FIREPLACE. IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty .
3 SR/SC Series "A" W oodb ur ning Fireplace 7412948 5/8" (16mm) 1/2" (13mm) 1/2" 36" (914mm) 38 " (971mm) 40" (1016mm) 5/8" (16mm) 22 &.
4 SR/SC Series "A" W oodb ur ning Fireplace 7412948 5/8" (16mm) 1/2" (13mm) 1/2" 42" (1067mm) 38 " (971mm) 46" (1 168mm) 5/8" (16mm) 22 .
5 SR/SC Series "A" W oodb ur ning Fireplace 7412948 Chase Installation Insulation methods shown are optional for cold climate, not a requirement for unit operation.
6 SR/SC Series "A" W oodb ur ning Fireplace 7412948 Chimney Requirements - Offset Installations 0 0 0 0 0 3" 1 1" 1 0 0 0 0 8 ¹⁄₄ " 20" 0 1 0 0 0 1 1 ¹⁄₄ ".
7 SR/SC Series "A" W oodb ur ning Fireplace 7412948 L 1 L 1 L T MODEL SK 2 W ALL CHIMNEY TOT AL LENGTH (L T ) INST ALLED LENGTH (L 1 ) SK81 SK818 SK83 SK84 1 1 " 17 .
8 SR/SC Series "A" W oodb ur ning Fireplace 7412948 Insulating Fireplace Enclosure for Cold Climates If you live in a cold climate, it is not required but highly recommended that you insulate fireplace enclosure to eliminate cold air penetration as much as possible.
9 SR/SC Series "A" W oodb ur ning Fireplace 7412948 Framing Framing can be constructed before or after the fireplace is set in place, however , most installers build the frame before setting the fireplace. Frame fireplace with 2 x 4 lumber or heavier materials.
10 SR/SC Series "A" W oodb ur ning Fireplace 7412948 Straight-Up Chimney Installation T o mark the centerline of the flue, put the fireplace in final position and measure out from the wall: 9 ¹⁄₄ " (235mm). Mark a spot on the ceiling directly above the fireplace.
1 1 SR/SC Series "A" W oodb ur ning Fireplace 7412948 NOTE: Safety strips are not required over noncom- bustible floors where all supports at the base of the fireplace are noncombustible. Four (4) nailing flanges are incorporated on each cor- ner of the surround.
12 SR/SC Series "A" W oodb ur ning Fireplace 7412948 Continue installing the pipe as required until pipe is installed up through the ceiling. At this point, you must install a firestop spacer . Installing the Firestop Spacer in the Ceiling Hole A firestop spacer is used to keep pipe spaced properly and required for safety .
13 SR/SC Series "A" W oodb ur ning Fireplace 7412948 Install the attic insulation shield with the flanges on its base extending down into the framing hole. Nail each corner of attic insulation shield to the framing members of the ceiling hole using 8d nails.
14 SR/SC Series "A" W oodb ur ning Fireplace 7412948 Installing T op Housing or T ermination Follow the installation instructions provided with the chimney termination you have selected. Installing Chimney In a Chase Refer to Page 5, Figure 5 for an illustration of a typical chase installation.
15 SR/SC Series "A" W oodb ur ning Fireplace 7412948 MA81 rev . 8/5/97 1 " Ref. Combustible materials are permitted within a shaded area shown in Figure 23 titled Minimum W all Clearances. * ** MA81 Fig. 22 Combustible mantle clearances.
16 SR/SC Series "A" W oodb ur ning Fireplace 7412948 Hearth Installation A hearth extension is required to protect a combustible floor in front of the fireplace. Refer to Figure 23 for mini- mum dimensions and mounting detail. NOTE: Hearth Extension must not cover the air inlet opening of a fireplace.
17 SR/SC Series "A" W oodb ur ning Fireplace 7412948 COMMON MA TERIALS AND F ACTORS MA TERIAL K* R MINIMUM THICKNESS EH2416 Common Brick 0.458 5.0 1.09 0.50 in.** 0.10 5.46 in.** (CFM Corporation) R V alue is for Zx inch. * Units of K = BTU/SQ FT/HR/˚F/IN ** Thickness of Listed Material FP533ADD Addendum 6/1/99 djt 8/4/99 changed .
18 SR/SC Series "A" W oodb ur ning Fireplace 7412948 Installing Line for Gas Logs CFM Corporation fireplaces are designed to accept a 1/2" (13mm) gas line for installation of an approved gas appliance. (CFM Corporation manufactures a wide va- riety of gas logs for use in CFM Corporation fireplaces.
19 SR/SC Series "A" W oodb ur ning Fireplace 7412948 1 2 3 4 5 6 a b c 7 8 9 10 1 1 12 948 SR/SC parts 5/16/00 djt d 14 13 e CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
20 SR/SC Series "A" W oodb ur ning Fireplace 7412948 The following accessories for this appliance are available from your local Majestic Fireplaces distributor . Should you need additional information beyond what your distributor can furnish, contact: CFM Corporation, 2695 Meadowvale Blvd.
21 SR/SC Series "A" W oodb ur ning Fireplace 7412948 Chimney Components Round T op T ermination T op used to terminate chimney at roof. RL TSK8 (Flashing not included.) Round T op T ermination - T op used to terminate chimney at chase. RL TSK8L Extended (Flashing not included.
22 SR/SC Series "A" W oodb ur ning Fireplace 7412948 Chimney Collar Enclosure Installs on the "over the chimney collar" of the CCE-SK fireplace; provides outside air to assist in cooling the chimney system. Attic Insulation Shield Used to prevent insulation from coming in AIS-SK contact with the chimney system.
23 SR/SC Series "A" W oodb ur ning Fireplace 7412948 LIMITED W ARRANTY & 30 YEAR PROTECTION PLAN For MAJESTIC FIREPLACES ® PRE-ENGINEERED Fireplace Systems CFM Corporation warrants its .
2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www .cfmcorp.com CFM Corporation.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Vermont Casting SR36A c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Vermont Casting SR36A - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Vermont Casting SR36A, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Vermont Casting SR36A va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Vermont Casting SR36A, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Vermont Casting SR36A.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Vermont Casting SR36A. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Vermont Casting SR36A ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.