Manuel d'utilisation / d'entretien du produit H33BDVRRNP du fabricant Vermont Casting
Aller à la page of 32
10004798 1 1/02 Rev . 0 INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER Builder Rear V ent Direct V ent DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance.
2 Pyromaster © H33BDVRRN/P 10004798 Installation & Operating Instructions ........................................................................................... 3 Locating Your Fireplace ......................................................
3 Pyromaster © H33BDVRRN/P 10004798 A) Flat on wall B) Cross corner C) **Island D) *Room divider E) *Flat on wall corner F) Chase installation Y) 6" minimum Note (Fig. 1): ** Island (C) and Room Divider (D) installation is possible as long as the horizontal portion of the vent system (X) does not exceed 20 feet (610cm).
4 Pyromaster © H33BDVRRN/P 10004798 Fireplace Dimensions Fig. 2 Fireplace specifications and framing dimensions. F Q - Rough Opening Width Rough Opening Height Rough Opening Depth M M O N P E I H J C A D R B K L G 4758 Ref.
5 Pyromaster © H33BDVRRN/P 10004798 Appliance T op.............................................. 0” (0 mm) Bottom........................................ 0” (0 mm) Side............................................ 0” (0 mm) Back.................
6 Pyromaster © H33BDVRRN/P 10004798 Noncombustible materials such as brick or tile may be extended over the edges of the face of the fireplace. DO NOT cover any vent or grille panels. If a T rim Kit is going to be installed on the fireplace, the brick or tile will have to be installed flush with the edges of the fireplace.
7 Pyromaster © H33BDVRRN/P 10004798 Installation 1. Thread the wiring through the holes on the end panels of the fireplace. Take care not to cut the wire or insulation on metal edges. Route the wire to a conveniently located receptacle box. 2. Attach the wire to the ON/OFF switch and install the switch into the receptacle box.
8 Pyromaster © H33BDVRRN/P 10004798 V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINATION AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED H I Fixed Closed Fixed Closed Operable Opera.
9 Pyromaster © H33BDVRRN/P 10004798 Outside Corner Inside Corner Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors.
10 Pyromaster © H33BDVRRN/P 10004798 Twist Lock Pipes When using CFM Corporation twist-lock pipe it is not necessary to use sealant on the joints. The only areas of the venting system that need to be.
11 Pyromaster © H33BDVRRN/P 10004798 STEP 1 Locate vent opening on the wall. To locate hole center consult with appropriate fireplace dimensions, Page 4. Frame as shown below. Combustible Walls: Cut a 10 ³⁄₈ ”H (264 mm) x 9 ³⁄₈ ” W (240 mm) hole through the exterior wall and frame as shown.
12 Pyromaster © H33BDVRRN/P 10004798 STEP 5 Guide the vent termination 4” collar into the 4” pipe then the 7” collar into the 7” pipe. Do not force the venting into position. If the pipes do not line up with the termination collars, disassemble pipes and reattach to the fireplace collar.
13 Pyromaster © H33BDVRRN/P 10004798 Vertical Sidewall Installations Example: According to the chart the maximum horizontal vent length in a system with a 7.5' vertical rise is 20' (6 m) and if a 90 ° elbow is required in the horizontal vent it must be reduced to 17' (5.
14 Pyromaster © H33BDVRRN/P 10004798 STEP 2 Measure wall thickness and cut adjustable zero clear- ance sleeve parts to proper length (MAXIMUM 12”/305 mm). (Fig. 22) Adjust sleeve to minimum (9 ³⁄₈ ” x 9 ³⁄₈ ”) and attach to firestop with #8 sheet metal screws (supplied).
15 Pyromaster © H33BDVRRN/P 10004798 Below Grade Installations Do not back fill around snorkel. A clearance of at least 4” (100mm) must be maintained between the snorkel and the soil. STEP 6 Apply high temperature sealant to 4” (100 mm) and 7” (175 mm) collars or the termination one inch away from the crimped end.
16 Pyromaster © H33BDVRRN/P 10004798 If the foundation is recessed, use recess brackets (not supplied) for securing lower portion of the snorkel. Fasten brackets to wall first, then secure to snorkel with self drilling #8 x 1/2 sheet metal screws. It will be necessary to extend vent pipes out as far as protruding wall face.
17 Pyromaster © H33BDVRRN/P 10004798 If there is room above ceiling level, firestop spacer must be installed on both the bottom and the top side of the ceiling joists. If an attic is above ceiling level a 7DVAIS (Attic Insulation Shield) must be installed.
18 Pyromaster © H33BDVRRN/P 10004798 Twist Lock Venting Components 7TDVRVT-Through the wall Rear Vent Termination Starter Kit-Model7TDVSK-Sidewall Venting Starter Kit-Model 7TDVSKV-Vertical Venting f.
19 Pyromaster © H33BDVRRN/P 10004798 Crimped End Venting Components 7TDVRVT-Through the wall Rear Vent Termination Starter Kit-Model 7TDVSK-Sidewall Venting Starter Kit-Model 7TDVSKV-Vertical Venting.
20 Pyromaster © H33BDVRRN/P 10004798 Only glass approved by the CFM Corporation should be used on this fireplace. The top louvre panel is removed by lifting the panel vertically and pulling it away from the appliance. (Fig. 35) The lower access door is hinged along the bottom edge and is folded down to allow access.
21 Pyromaster © H33BDVRRN/P 10004798 For units equipped with ‘HI/LO’ valves the flame adjustment is accomplished by rotating the ‘HI/LO’ adjustment knob located near the center of the gas control valve. (Fig. 38) It is important to periodically perform a visual check of the pilot and burner flames.
22 Pyromaster © H33BDVRRN/P 10004798 3. Open control access panel. 4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. Turn off all electrical power to the fireplace.
23 Pyromaster © H33BDVRRN/P 10004798 T roubleshooting – Honeywell VS8421 START CHECK Remove Glass Doors Before Service Work GAS SUPPLY ON ▼ ▼ ▼ ▼ ▼ PILOT LIGHTS WITH PIEZO IGNITOR • Lockout Has Engaged. Wait 60 Seconds And Try Again. • For Spark At Electrode While Depressing Piezo 1/8" Gap To Pilot Hood Needed.
24 Pyromaster © H33BDVRRN/P 10004798 This unit is factory setup for use with natural gas. The conversion of this appliance from natural gas to propane gas must be carried out by an authorized service provider. LP Conversion Kit Components (Supplied with unit.
25 Pyromaster © H33BDVRRN/P 10004798 Maintenance Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out.
26 Pyromaster © H33BDVRRN/P 10004798 L O H I PILOT ADJ PILOT ON OFF 2 3a/b 1 1a 1b 1c 4 5 6 7 8 9a/b 11 12 13 17 14 15 16 18 10 4758 CFM Harris Systems reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
27 Pyromaster © H33BDVRRN/P 10004798 4. Pilot, T op Convertible SIT 10002266 * Pilot Orifice - SIT T op Convertible Nat. (not shown) 10002268 * Pilot Orifice - SIT T op Convertible Prop. (not shown) 10002269 5. Pilot Hood, SIT T op Convertible 10002385 6.
28 Pyromaster © H33BDVRRN/P 10004798 FK24 Fan Assembly This auxiliary fan system increases the efficiency of the circulation of the heated air. The FK24 fan kit allows variable speed control of the circulation fan and also incorporates a heat sensor in the circuit.
29 Pyromaster © H33BDVRRN/P 10004798 The fireplace, when installed, must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electric Code. For USA installations follow the local codes and the national electrical code ANSI/NFPA No.
30 Pyromaster © H33BDVRRN/P 10004798 Do not remove the existing window frame assembly. T op Louvre Bay Window Frame Bottom Brass T rim Bottom Louvre Assemblies Spacers Ceramic Refractory Screws FP1 195 Fig. 47 Bay window installation. Ceramic Refractory Decorative Bay Windows 4.
31 Pyromaster © H33BDVRRN/P 10004798 Optional remote control units are available to control different functions of the appliances. Model Function(s) Controlled RM4 ON/OFF w/batteries Remote Controls Bay Window Screen A Bay Window Screen Kit is available for the H33BDVRRN/P.
BASIC W ARRANTY : CFM Harris Systems (hereinafter referred to collectively as the "Company") warrants that your new Pyromaster Gas Appliance is free from manufacturing and material defects for a period of one year from date of installation, subject to the following conditions and limitations.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Vermont Casting H33BDVRRNP c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Vermont Casting H33BDVRRNP - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Vermont Casting H33BDVRRNP, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Vermont Casting H33BDVRRNP va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Vermont Casting H33BDVRRNP, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Vermont Casting H33BDVRRNP.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Vermont Casting H33BDVRRNP. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Vermont Casting H33BDVRRNP ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.