Manuel d'utilisation / d'entretien du produit DVRT41 du fabricant Vermont Casting
Aller à la page of 48
Homeowner's Installation and Operating Manual INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER Direct V ent Model: DVRT41 DO NOT STORE OR USE GASOLINE OR OTHER FLAM- MABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
2 DVRT41 Direct Vent Gas Fireplace 10006740 Installation & Operating Instructions ........................................................................................................... 3 Locating Your Fireplace ...............................
3 DVRT41Direct Vent Gas Fireplace 10006740 A) Flat on wall B) Cross corner C) **Island D) *Room divider E) *Flat on wall corner F) Chase installation Y) 6" minimum Note (Fig. 1): ** Island (C) and Room Divider (D) installation is possible as long as the horizontal portion of the vent system (X) does not exceed 20’ (610cm).
4 DVRT41 Direct Vent Gas Fireplace 10006740 Ref. DVRT41 A 41” (1041mm) B 37” (940mm) C 36” (914mm) D2 4 ¹⁄₂ ” (622mm) E7 ” (178mm) F6 ” (152mm) G1 ¹⁄₄ ” (32mm) H1 9 ¹⁄₂ .
5 DVRT41Direct Vent Gas Fireplace 10006740 Fireplace Dimensions (Installed as Rear V ent) H R - Rough Opening Width Gas Line Access Rough Opening Height Electrical Access Rough Opening Depth U U V T J S I J P O N M G F D E G A Q L K B Recessed Nailing Flange Ref.
6 DVRT41 Direct Vent Gas Fireplace 10006740 Mantels The height that a combustible mantel is fitted above the fireplace is dependent on the depth of the mantel. This also applies to the distance between the mantel leg (if fitted) and the fireplace. For the correct mounting height and widths, refer to Figures 4a, 4b and the Mantel Chart below.
7 DVRT41Direct Vent Gas Fireplace 10006740 Framing And Finishing Check fireplace to make sure it is lev- elled and properly positioned. To mount the appliance: 1. Choose the location. 2. This unit comes with four (4) flanges pre-mounted on both sides of the fireplace to allow two different drywall thicknesses to be used.
8 DVRT41 Direct Vent Gas Fireplace 10006740 Remote ON/OFF Switch Installation Do not wire the remote ON/OFF wall switch for this gas appliance into a 120v power supply. 1. Thread wire through the electrical knockout located on either side of the unit.
9 DVRT41Direct Vent Gas Fireplace 10006740 The EB-1 electrical junction box has been supplied standard on the DV360/580 models to allow for the easy installation of an optional fan kit. To connect the EB-1 box to the house electrical supply, follow the steps below.
10 DVRT41 Direct Vent Gas Fireplace 10006740 FP1031 Fig. 13 Completed conversion. After conversion to top vent configura- tion, the 4” (102mm) flue pipe should be concentric within the 7” (175mm) outer collar. Your fireplace is approved to be vented either through the side wall, or vertical through the roof.
11 DVRT41Direct Vent Gas Fireplace 10006740 V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINATION AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED H I Fixed Closed Fixed Closed Operable Operable Fixed Closed V B INSIDE CORNER DETAIL V A G V N N V V G G A CFM145a Fig.
12 DVRT41 Direct Vent Gas Fireplace 10006740 Outside Corner Inside Corner Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors.
13 DVRT41Direct Vent Gas Fireplace 10006740 Male End Female End Screw Holes TWL100 Fig. 17 T wist-Lock pipe joints. Twist Lock Pipes When using twist lock pipe it is not necessary to use sealant on the joints.
14 DVRT41 Direct Vent Gas Fireplace 10006740 Rear Wall Vent Installation Step 1 Locate and cut the vent opening in the wall. For com- bustible walls first frame in opening. (Fig. 21) NOTE: When using flex vent, the opening will have to be measured according to the 1/2” (13mm) rise in 12” (305mm) vertical run.
15 DVRT41Direct Vent Gas Fireplace 10006740 Finished Wall Vent Termination Fig. 23 Side view of final unit location. FP1005 Vertical Sidewall Application Since it is very important that the venting sy.
16 DVRT41 Direct Vent Gas Fireplace 10006740 In Figure 28 & 29, dimension A plus B must not be greater than 17’ (5.2m) • The maximum number of 45 ° elbows permitted per side wall installation is two (2). These elbows can be installed in either the vertical or horizontal run.
17 DVRT41Direct Vent Gas Fireplace 10006740 X X FP1181 Fig. 33 Vertical height requirements. Vertical Sidewall Installation Twist Lock Pipe Step 1 Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole location.
18 DVRT41 Direct Vent Gas Fireplace 10006740 Sealing vent pipe and firestop gaps with high temperature sealant will restrict cold air being drawn in around fireplace. Step 7 Apply high temperature sealant to 4” (102mm) and 7” (178mm) collars or the termination one inch away from crimped end.
19 DVRT41Direct Vent Gas Fireplace 10006740 Below Grade Installation When it is not possible to meet the required vent terminal clearances of 12” (305mm) above grade level, a snorkel kit is recommended. It allows installation depth down to 7” (178mm) below grade level.
20 DVRT41 Direct Vent Gas Fireplace 10006740 Vertical Through-the-Roof Installation 1. Locate your fireplace. 2. Plumb to center of the (4”) flue collar from ceiling above and mark position. 3. Cut opening equal to 9 ³⁄₈ ” x 9 ³⁄₈ ” (240mm x 240mm).
21 DVRT41Direct Vent Gas Fireplace 10006740 Typical Roof Support Application Typical Ceiling Support Application Fig. 42 Venting supports. FP1184 3 #5 Sheet Metal Screws per Joint Sealant TWL101a Fig. 44 Roof flashing. Storm Collar Min. 2’ (610 mm) FP1185 Fig.
22 DVRT41 Direct Vent Gas Fireplace 10006740 7TDVRVT - Through the wall Rear Vent Termination Starter Kit - Model 7TDVSK - Sidewall Venting (Twist Lock Pipe) Model 7FDVSK - Sidewall Venting (Flex Vent.
23 DVRT41Direct Vent Gas Fireplace 10006740 Glass Information Only glass approved by CFM Specialty Home Products should be used on this fireplace. • The use of any non-approved replacement glass will void all product warranties. • Care must be taken to avoid breakage of the glass.
24 DVRT41 Direct Vent Gas Fireplace 10006740 Installation of Logs Remove front glass. (Refer to "Window Frame Assem- bly Removal" Section, Fig. 46) Remove logs from packaging. As with all plastics — these are not toys and should be kept away from children and infants.
25 DVRT41Direct Vent Gas Fireplace 10006740 Flame Characteristics It is important to periodically perform a visual check of the pilot and the burner flames. Compare them to the pictorials illustrated below. (Figs. 51, 52) If any of the flames appear abnormal call a service person.
26 DVRT41 Direct Vent Gas Fireplace 10006740 3. Open louvre assembly bottom. 4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. Turn off all electrical power to the fireplace.
27 DVRT41Direct Vent Gas Fireplace 10006740 Lighting & Operating Instructions For Fireplaces equipped with SIT822 Gas Valve (EN or EP) A. This fireplace is equipped with an ignition device which automatically lights the pilot. DO NOT try to light the pilot by hand.
28 DVRT41 Direct Vent Gas Fireplace 10006740 Instructions for RF Comf or t Control V alve The Comfort Control V alve allows remote control of temperature, fan and flame appearance. NO TE: The antenna should hang in free air away from grounded metal. Operation 1.
29 DVRT41Direct Vent Gas Fireplace 10006740 Dela y Timer Mode The shut off delay timer has a maximum of 2 hours and a minimum of zero minutes. T o change the timer level, press the time key followed by an arrow key . Pushing the key once will change the timer by 10 minutes.
30 DVRT41 Direct Vent Gas Fireplace 10006740 LED Count Service Action 8 Replace valve 7 Confirm stepper motor connection exists 5 Confirm fan connection exists and works 4 Confirm gas type; jumper in place 3 Replace thermopiles 2T urn fan ON NOTE: Some keys are not active.
31 DVRT41Direct Vent Gas Fireplace 10006740 Light pilot burner Set manual switch to local or remote Release pilotstat knob T urn pilotstat knob from PILOT to ON If manual switch is set to LOCAL, did m.
32 DVRT41 Direct Vent Gas Fireplace 10006740 Window Frame Assembly to be Removed Before Service Work Tr oubleshooting – Hone ywell VS8421 START CHECK Gas Supply On ▼ ▼ ▼ ▼ ▼ Pilot Lights With Piezo Ignitor • Lockout Has Engaged. Wait 60 Seconds And Try Again.
33 DVRT41Direct Vent Gas Fireplace 10006740 W ARNING: Before doing an y gas contr ol service work, remove glass fr ont. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Spark ignitor will not light A. Defective or misaligned Using a match, light pilot. If pilot lights, turn off electrode at pilot.
34 DVRT41 Direct Vent Gas Fireplace 10006740 SIT 822 Valve with a Honeywell Electronic Igniter Troubleshooting the Gas Control System ST ART •TURN GAS SUPPL Y OFF • TURN ON/OFF SWITCH TO CALL FOR .
35 DVRT41Direct Vent Gas Fireplace 10006740 Fuel Conversion Instructions To convert the DV360/580 units for use with a different gas follow these instructions. Before proceeding, turn control knob on valve to “ OFF ” and turn gas supply OFF . Turn OFF any electricity that may be going to the appliance.
36 DVRT41 Direct Vent Gas Fireplace 10006740 Fuel Conversion Instructions Honeywell Comfort Control Valve ONLY WARNING: The conversion must only be undertaken by a qualified, certified gas appliance installer. LOCAL REMOTE O N ¥ PILOT OFF ¥ LED Motor Top Cap Piezo Ignitor Local/ Remote Switch Pilotstat Knob LED Plug Antenna FP1037 Fig.
37 DVRT41Direct Vent Gas Fireplace 10006740 LOCAL Center Plunger Blue - NG Red - LP Motor Top Cap FP1037b Fig. 65 Depressd and turn center plunger. Fig. 67 Burner orifice replacement. CO124 Rear Burner Orifice: Refer to Conversion Kit Orifice Chart Front Burner Orifice: Refer to Conversion Kit Orifice Chart 15.
38 DVRT41 Direct Vent Gas Fireplace 10006740 Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out.
39 DVRT41Direct Vent Gas Fireplace 10006740 2 3 4 5 6a,b 7 8 9a 9b 9e 9c 9d 10 11 12 13 14 15 16 17 22 23 P I L O T O N O F F P IL O T A D J L O H I TPTH TH TP 24a,b 25a,b 26a,b 30 27 32 28 29 33 HI L.
40 DVRT41 Direct Vent Gas Fireplace 10006740 DVRT41 (continued) Ref. Description DVRT41 1. Log Set DVRT41 (Complete) 10006185 1a. Log Rear (G7) 10006798 1b. Log Front Right (G6) 10006797 1c. Log Front Left (G10) 10006801 1d. Log Front Center (G9) 10006800 1e.
41 DVRT41Direct Vent Gas Fireplace 10006740 DVRT41 (continued) Ref. Description DVRT41 30. Thermocouple - RN/RP 53373 31a. V alve - SIT 822 - EN 57884 31b. V alve - SIT 822 - EP 57883 32. Thermopile - RN/RP 51827 33. Hood Pilot 3 W ay 10002385 34a. Pilot Assembly SIT T op Conv .
42 DVRT41 Direct Vent Gas Fireplace 10006740 Fuel Conversion Kits Natural Gas to LP DVRT41RN/EN Kit #10006826 DVRT41RFN Kit #10006827 LP to Natural Gas DVRT41RP/EP Kit #10006825 DVRT41RFP Kit #10006828 DVRT41 (continued) Ref. Description DVRT41 67. Refractory Bay Window 10000506 68a.
43 DVRT41Direct Vent Gas Fireplace 10006740 Optional Accessories A vailab le FK12 Fan Assembly 1. Open louvre assembly bottom. 2. Install FK12 fan in back of unit between hearth supports.
44 DVRT41 Direct Vent Gas Fireplace 10006740 Remote Controls Optional remote control units are available to control different functions of the appliance.
45 DVRT41Direct Vent Gas Fireplace 10006740 This appliance may be installed as an OEM installation in a manufactured home (US only), or a mobile home; it must be installed in accordance with the manuf.
46 DVRT41 Direct Vent Gas Fireplace 10006740 8. Remove the compression fitting which holds the aluminium tubing in the pilot assembly. This will reveal the pilot orifice which must be replaced with the one provided in the conversion kit.
47 DVRT41Direct Vent Gas Fireplace 10006740 BASIC WARRANTY CFM Specialty Home Products (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas Fir.
Efficiency Ratings Model EnerGuide Ratings Steady State (%) D.O.E. Fireplace Efficiency (%) Fan-OFF Fan-ON (AFUE%) DVRT41RN 64 83 84 64 DVRT41RP 64 84 85 64 DVRT41RFN 64 83 84 64 DVRT41RFP 64 84 85 64 DVRT41EN 66.1 83 84 64 DVRT41EP 66.1 84 85 64 410 Admiral Blvd.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Vermont Casting DVRT41 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Vermont Casting DVRT41 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Vermont Casting DVRT41, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Vermont Casting DVRT41 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Vermont Casting DVRT41, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Vermont Casting DVRT41.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Vermont Casting DVRT41. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Vermont Casting DVRT41 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.