INST ALLER: DO NOT DISCARD THIS MANUAL - LEA VE FOR HOMEOWNER 10002789 08/00 Rev . 0 I NST ALLA TION I NSTRUCTIONS & H OMEOWNER ' S M ANUAL DO NOT ST ORE OR USE GASOLINE OR OTHER FLAMMABLE V APOURS AND/OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
DBT33/DBT36/DBT39 -2- 10002789/0 T ABLE O F C ONTENTS Please Read The Installation & Operating Instructions Car efully Befor e Using The Appliance.
10002789/0 -3- DBT33/DBT36/DBT39 This gas replace should be installed by a qualied installer in accordance with local building codes and with current CAN /CGA-B149 (. 1 or .2) Installation codes for Gas Burning Fireplaces and Equipment. FOR U.S.
DBT33/DBT36/DBT39 -4- 10002789/0 A PPLIANCE D IMENSIONS Appliance Dimensions Ref. DBT33 DBT36 DBT39 A 838 mm (33") 914 mm (36") 991 mm (39") B 733 mm (28.
10002789/0 -5- DBT33/DBT36/DBT39 C LEARANCE TO C OMBUSTIBLES Appliance T op ............................. 0 mm (0") Bottom ....................... 0 mm (0") Side ............................ 0 mm (0") Back ........................... 0 mm (0") V enting Concentric sections of DV V ent T op, bottom & sides .
DBT33/DBT36/DBT39 -6- 10002789/0 F INAL F INISHING Non-combustible materials such as brick or tile may be extended over the edges of the face of the appliance. DO NOT cover any vent or grille panels. If a T rim Kit is going to be installed on the replace, the brick or tile will have to be installed ush with the edges of the appliance.
10002789/0 -7- DBT33/DBT36/DBT39 G AS L INE I NST ALLA TION When purging the gas lines, the front glass must be removed. The gas pipeline can be brought in through the rear of the replace as well as the bottom. Knockouts are provided on the bottom behind the valve to allow for the gas pipe installation and testing of any gas connection.
DBT33/DBT36/DBT39 -8- 10002789/0 C ONVER TING T HE A PPLIANCE F ROM LP TO N A TU RAL G AS OR N A TURAL G AS T O LP . The DBT33 is convertible between Natural Gas an LP gas (and vice-versa) with the use of a conversion kit purchased seperately , see your dealer for the correct part number .
10002789/0 -9- DBT33/DBT36/DBT39 A = clearance above grade, veranda, por ch, deck, or bal- cony [* 12 inches (305mm) minimum] B = clearance to window or door that may be opened [12" (306mm)].
DBT33/DBT36/DBT39 -10- 10002789/0 Fig. 1 1 Fig. 12 Fig. 13 Fig. 14 Fig. 15.
10002789/0 -1 1- DBT33/DBT36/DBT39 H OW T O U SE T HE V ENT G RAPH The vent chart should be read in conjunction with the follow- ing vent installation instructions to determin the relationship of the vertical and horizontal dimensions of the vent system 1.
DBT33/DBT36/DBT39 -12- 10002789/0 V E R T ICA L S IDE W ALL A PP LIC A TIO NS Since it is very important that the venting system maintain its balance between the combustion air intake and the ue gas exhaust, certain limita- tions as to vent congurations apply and must be strictly adhered to.
10002789/0 -13- DBT33/DBT36/DBT39 V ER TICAL S IDEW ALL I NST ALLA TIONS STEP 1 Locate vent opening on the wall. It may be necessary to rst position the replace and measure to obtain hole location. Depending on whether the wall is combustible or non-combus- tible, cut opening to size.
DBT33/DBT36/DBT39 -14- 10002789/0 STEP 6 Use appropriate length of pipe sections - telescopic or xed - and install the horizontal vent sections. The sections which go through the wall are packaged with the starter kit, and can be cut to suit if necessary .
10002789/0 -15- DBT33/DBT36/DBT39 DO NOT BACK FILL AROUND SNORKEL. A CLEARANCE OF A T LEAST 4” MUST BE MAINT AINED BETWEEN THE SNORKEL AND THE SOIL If the foundation is recessed, use recess brackets (not supplied) for securing lower portion of the snorkel.
DBT33/DBT36/DBT39 -16- 10002789/0 • 7DVCS must be used to support offsets. (Fig. 36)This application will require that you rst determine the roof pitch and use the appropriate starter kit. (See V enting Components List) • The minimum height of the vent above the highest point of penetration through the roof is 2'.
10002789/0 -17- DBT33/DBT36/DBT39 V ER TICAL T HROUGH -T HE -R OOF I NST ALLA TION 1. Locate your replace. 2. Plumb to centre of the (4") ue collar from ceiling above and mark position. 3. Cut opening equal to 9-3/8" x 9-3/8" (240 mm x 240 mm).
DBT33/DBT36/DBT39 -18- 10002789/0 C RIMPED E ND V ENTING C OMPONENTS Starter Kit -Model 7DVSK - Sidewall V enting Starter Kit - Model 7TDVSKV - V ertical V enting for 7TDVSKV -A order 1/12 to 6/12 roo.
10002789/0 -19- DBT33/DBT36/DBT39 T WIST L OCK V ENTING C OMPONENTS Starter Kit -Model 7TDVSK - Sidewall V enting Starter Kit - Model 7TDVSKV - V ertical V enting for 7TDVSKV -A order 1/12 to 6/12 roo.
DBT33/DBT36/DBT39 -20- 10002789/0 G ENERAL O PERA TING I NSTRUCTIONS G LASS I NFORMA TION Only glass approved by CFM Majestic Inc. should be used on this replace. • The use of any non-approved replacement glass will void all product warranties. • Care must be taken to avoid breakage of the glass.
10002789/0 -21- DBT33/DBT36/DBT39 I NST ALLA TION OF L OGS & L A V A R OCK Refer to the log identication chart to identify specic log numbers. 1. Remove the front glass / frame assembly . 2. Remove the logs from their packaging. The logs are fragile and should be handled with care.
DBT33/DBT36/DBT39 -22- 10002789/0 F LAME & T EMPERA TURE A DJUSTMENT RN/RP & EN/EP Models For units equipped with ‘HI/LO’ valves the ame adjustment is accomplished by rotating the ‘HI/LO’ adjustment knob located near the centre of the gas control valve, Fig.
10002789/0 -23- DBT33/DBT36/DBT39 LIGHTING INSTRUCTIONS 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to "OFF". Do not force. 5. Close control access panel. 10. Push the control knob all the way in and hold.
DBT33/DBT36/DBT39 -24- 10002789/0 TROUBLE SHOOTING THE GAS CONTROL SYSTEM HONEYWELL MILLIVOL T V AL VE.
10002789/0 -25- DBT33/DBT36/DBT39 TROUBLE SHOOTING THE GAS CONTROL SYSTEM SIT NOV A 820 MILLIVOL T V AL VE Note: Before trouble shooting the gas control system, be sure external gas shut off is in the "On" position. W ARNING: BEFORE DOING ANY GAS CONTROL SER VICE WORK, REMOVE GLASS FRONT .
DBT33/DBT36/DBT39 -26- 10002789/0 R EPLACEMENT P AR TS L IST Items marked ‘*’ ar e not shown in the following parts pictorial page. Ref. Description DBT33 DBT36 DBT39 1 Log Set (complete) 10000470.
10002789/0 -27- DBT33/DBT36/DBT39 Ref. Description DBT33 DBT36 DBT39 * Knob, fan speed control, (FK24 option) 51882 51882 51882 17 Fan assembly , with bracket (FK12 option) ZA11 10 ZA11 10 ZA1 1 10 18.
DBT33/DBT36/DBT39 -28- 10002789/0 P AR TS P ICT ORIAL.
10002789/0 -29- DBT33/DBT36/DBT39 O PTIONAL A CCESSORIES A V AILABLE EB-1 E LECTRICAL B OX The EB-1 Electrical junction box when tted and correctly wired gives an easy and convenient power outlet for the optioal fan kit.
DBT33/DBT36/DBT39 -30- 10002789/0 W IRING I NSTRUCTIONS The replace, when installed, must be electri- cally connected and grounded in accordance with local codes or , in the absence of local codes, with the current CSA C22.1 Canadian Electric Code.
10002789/0 -31- DBT33/DBT36/DBT39 C ERAMIC R EFRACTOR Y K ITS Ceramic refractory panels are available in kit form for the DBT series appliances. Appliance Model Kit Name DBT33 33BDVTCR DBT36 36BDVCR DBT39 39BDVCR T ake care when handling the refractory panels as they are fragile until held in place and sup- ported.
DBT33/DBT36/DBT39 -32- 10002789/0 D ECORA TIVE B A Y W INDOWS Bay window kits are available for the DBT33, DBT36 & DBT39 model appliances. When tting the Bay W indow Kits the original front frame/glass assembly MUST remain in place. The Bay W indow kit is tted over the existing front glass.
10002789/0 -33- DBT33/DBT36/DBT39.
DBT33/DBT36/DBT39 -34- 10002789/0 410 Admiral Blvd. • Mississauga, Ontario , Canada L5T 2N6 • 905-670-7885 www .vermontcastings.com CFM Majestic, Inc.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Vermont Casting DBT36 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Vermont Casting DBT36 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Vermont Casting DBT36, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Vermont Casting DBT36 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Vermont Casting DBT36, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Vermont Casting DBT36.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Vermont Casting DBT36. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Vermont Casting DBT36 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.