Manuel d'utilisation / d'entretien du produit 33LDVR du fabricant Vermont Casting
Aller à la page of 40
Installation Instructions and Homeowner ’ s Manual 10007317 12/06 Rev . 7 Builder Rear V ent Direct V ent Models: 33LDVR, 36LDVR, 39LDVR, 43LDVR DO NOT ST ORE OR USE GASOLINE OR OTHER FLAMMABLE V APORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
2 LDVR Series Direct Vent Gas Fireplace 10007317 PLEASE READ THE INST ALLA TION & OPERA TING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a CFM Corporation fireplace. IMPORT ANT : Read all instructions and warnings carefully before starting installation.
3 LDVR Series Direct Vent Gas Fireplace 10007317 This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Appliances and Equipment. For USA Installations follow local codes and/or the current National Fuel Gas Code.
4 LDVR Series Direct Vent Gas Fireplace 10007317 Fireplace Dimensions F V - Rough Opening Width Rough Opening Height Rough Opening Depth S S U T R E I H J D A Q B K L G M O Gas Line Access Gas Line Access Low V oltage Electrical Access Electrical Access C Centerline of 7" Collar M N P Low V oltage Access Fig.
5 LDVR Series Direct Vent Gas Fireplace 10007317 T op of Unit to Ceiling ............................. 36” (914mm) Appliance T op ....................................................... 0” (0 mm) Bottom ............................................
6 LDVR Series Direct Vent Gas Fireplace 10007317 Noncombustible materials such as brick or tile may be extended over the edges of the face of the fireplace. DO NOT cover any vent or grille panels. If a T rim Kit is going to be installed on the fireplace, the brick or tile will have to be installed flush with the edges of the fireplace.
7 LDVR Series Direct Vent Gas Fireplace 10007317 Installation 1. Thread the wiring through the holes on the end panels of the fireplace. T ake care not to cut the wire or insulation on metal edges. Route the wire to a conveniently located receptacle box.
8 LDVR Series Direct Vent Gas Fireplace 10007317 The fireplace, when installed, must be electrically connected and grounded in accordance with local codes or , in the ab- sence of local codes, with the current CSA C22.1 Canadian Electrical Code. For USA installations follow local codes and the national electrical code ANSI/ NFP A No.
9 LDVR Series Direct Vent Gas Fireplace 10007317 Y our fireplace is approved to be vented either through the side wall, or vertically through the roof. • Only CFM Corporation venting components specifi- cally approved and labelled for this fireplace may be used.
10 LDVR Series Direct Vent Gas Fireplace 10007317 V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINA TION AIR SUPPL Y INLET AREA WHERE TERMINAL IS NOT PERMITTED H I Operable Operable Fixed Closed V B CFM145a DV T ermin Location 5/01/01 Rev .
1 1 LDVR Series Direct Vent Gas Fireplace 10007317 General Information Assembling V ent Pipes Canadian Installations: V enting system must be installed in accordance with the current CSA-B149.1 installation code. USA Installations: The venting system must conform with local codes and/ or the current National Fuel Gas code ANSI Z223.
12 LDVR Series Direct Vent Gas Fireplace 10007317 The vent chart should be read in conjunction with the following vent installation instructions to determine the relationship of the vertical and horizontal dimensions of the vent system. 1. Determine the height of the center of the horizontal vent pipe exiting through the outer wall.
13 LDVR Series Direct Vent Gas Fireplace 10007317 DVR584-600 Rear vent no elbows 2/99 djt 20" (508mm) T op View Straight V enting FP836 Rear V ent-T op View 1 1/21/98 20" (508mm) Max. REAR VENT -TOP VIEW 20" (508mm) Max. T op View Rear V ent Corner Installation Fig.
14 LDVR Series Direct Vent Gas Fireplace 10007317 CFM133 DVR Series T ypical corner install 2/26/01 sta Zero Clearance Sleev e Firestop CFM133 Fig. 17 Firestop and zero clearance sleeve in place. FP1005 Side View V ent T ermination 1/25/00 djt Finished W all V ent T ermi - nation FP1005 Fig.
15 LDVR Series Direct Vent Gas Fireplace 10007317 •IMPORT ANT• Minimum clearance between vent pipes and combustible materials is one (1”) inch (25 mm) on bottom, sides and top. T wist Lock V ent Starter Kit 7TDVSK, plus T ransition Elbow 7TDVRT90 must be used in V ertical Sidewall installations.
16 LDVR Series Direct Vent Gas Fireplace 10007317 V ertical Sidewall Installation STEP 1 Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole location. Depending on whether the wall is combustible or noncombustible, cut opening to size.
17 LDVR Series Direct Vent Gas Fireplace 10007317 STEP 6 Apply high temperature sealant to 4” (102 mm) and 7” (178 mm) collars or the termination one inch away from the end. Guide the vent termination’s 4” and 7” collars into their respective vent pipes.
18 LDVR Series Direct Vent Gas Fireplace 10007317 Do not back fill around snorkel. A clearance of at least 4” (102mm) must be maintained between the snorkel and the soil. BG401 Snorkel 2/10/99 djt Foundation Recess Snorkel W all Screws Recess Brackets W atertight Seal Around Pipe Sheet Metal Screws BG401 Fig.
19 LDVR Series Direct Vent Gas Fireplace 10007317 V ertical Through-the-Roof Installation CFM100 Firestop-V ertical 09/20/00 1 1" 1 1" Joist Joist Firestop Spacer Nails (4) Upper Floor Attic Insulation Shield Ceiling Instal- lation CFM100 Fig.
20 LDVR Series Direct Vent Gas Fireplace 10007317 FP1022 T ypical Straight Up Installation 1/26/00 djt 40’ (12m) Storm Collar Roof Flash- ing V ent T ermination Roof 2’ Min. Roof Support Attic Insulation Shield Attic Insulation Joists Joists FP1022 Fig.
21 LDVR Series Direct Vent Gas Fireplace 10007317 V enting Components 584G V enting Components Firestop spacer 2/25/99 djt 584H V enting components attic insulation shield 2/25/99 djt 584I vent compon.
22 LDVR Series Direct Vent Gas Fireplace 10007317 Only glass approved by CFM Corporation should be used on this fireplace. The top louvre panel is removed by lifting the panel vertically and pulling it away from the appliance. (Fig. 39) The lower access door is hinged along the bottom edge and is folded down to allow access.
23 LDVR Series Direct Vent Gas Fireplace 10007317 1. Remove the top louvre assembly . 2. Open the bottom louvre. 3. Remove the window frame assembly . 4. Remove log box from inside firebox. 5. Unpack the logs from packaging and remove each log from its wrapping material.
24 LDVR Series Direct Vent Gas Fireplace 10007317 36LDVR 1. Place rear log (B135) on rear bracket (ensure log is seated prop- erly to the bracket and located to the two pins), so it will not move from side to side and is firmly posi- tioned on the bracket.
25 LDVR Series Direct Vent Gas Fireplace 10007317 43LDVR 1. Place rear log (BD15) on rear bracket (ensure log is centered and seated properly to the log support). 2. Place front left log (BD16). Use log’s bottom notch to locate it onto the front support and just rest on top of the burner housing tile.
26 LDVR Series Direct Vent Gas Fireplace 10007317 LG385 36LDV log flames 1/05 Glowing Embers LG385 LG384 33LDV log flames.
27 LDVR Series Direct Vent Gas Fireplace 10007317 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to “OFF”. Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. Turn of f all electrical power to the fireplace.
28 LDVR Series Direct Vent Gas Fireplace 10007317 Lighting and Operating Instructions For Fireplaces equipped with SIT822 Gas V alve (EN or EP) A. This fireplace is equipped with an ignition device which automatically lights the pilot. DO NOT try to light the pilot by hand.
29 LDVR Series Direct Vent Gas Fireplace 10007317 T roubleshooting - Honeywell Millivolt V alve Remove Window Frame Assembly Before Service Work ST ART CHECK Gas Supply On ▼ ▼ ▼ ▼ ▼ Pilot Lights With Piezo Ignitor • Lockout Has Engaged. W ait 60 Seconds And T ry Again.
30 LDVR Series Direct Vent Gas Fireplace 10007317 T roubleshooting the Gas Control System SIT 822 V alve with Synetek Electronic Control Operating Diagram Normal Operation ON/OFF Switch Closed? Safe S.
31 LDVR Series Direct Vent Gas Fireplace 10007317 The conversion of this appliance from one gas to another must be carried out by an authorized service provider . 1. Disconnect power to the unit and shut off the gas sup - ply . 2. Remove window frame assembly .
32 LDVR Series Direct Vent Gas Fireplace 10007317 Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out.
33 LDVR Series Direct Vent Gas Fireplace 10007317 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
34 LDVR Series Direct Vent Gas Fireplace 10007317 LDVR (continued) Ref. Description 33LDVR 36LDVR 39LDVR 43LDVR 1. Log Set (complete) 10007567 10007318 10008214 10008314 1a. Log Front Left A43 B136 BC15 BD16 1b. Log Front Right -- B137 BC16 BD17 1c. Log Front Center -- B138 B138 B138 1d.
35 LDVR Series Direct Vent Gas Fireplace 10007317 LDVR (continued) Ref. Description 33LDVR 36LDVR 39LDVR 43LDVR 34. Support Front Log 10007562 100071 12 10008416 10008469 35. ON/OFF Switch 51842 51842 51842 51842 36. Ceramic Refractory Lining Kit (Optional) GADT3I0 GADT3J0 GADT3K0 GADT3N0 37.
36 LDVR Series Direct Vent Gas Fireplace 10007317 FK24 Fan Assembly This auxiliary fan system increases the efficiency of the circulation of the heated air . The FK24 fan kit allows variable speed control of the circulation fan and also incorporates a heat sensor in the circuit.
37 LDVR Series Direct Vent Gas Fireplace 10007317 Ceramic refractory panels are available in kit form for the LDV series appliances Appliance Model Kit Name 33LDVR 33LDVRCR 36LDVR 36LDVCR 39LDVR 39LDV.
38 LDVR Series Direct Vent Gas Fireplace 10007317 Optional T rim Kits Louvre Accent T rim Appliance Model Main Louvre Kit Additional Louvre Polished Brass 33LDVR 33DVLMP 33DVLAP 36LDVR 36DVLMP 36DVLAP.
39 LDVR Series Direct Vent Gas Fireplace 10007317 BASIC W ARRANTY CFM Corporation (hereinafter referred to collectively as the Company) warrants that your new V ermont Castings or Majestic Gas Firepla.
Efficiency Ratings Model EnerGuide Ratings Steady State (%) D.O.E. Fireplace Efficiency (%) Fan-OFF Fan-ON (AFUE%) 33LDVRRN 62.6 81 82 59 33LDVRRP 62.6 82 83 59 33LDVREN 72.7 81 82 59 33LDVREP 72.7 82 83 59 36LDVRRN 57.5 81 82 58 36LDVRRP 57.5 82 83 58 36LDVREN 63.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Vermont Casting 33LDVR c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Vermont Casting 33LDVR - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Vermont Casting 33LDVR, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Vermont Casting 33LDVR va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Vermont Casting 33LDVR, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Vermont Casting 33LDVR.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Vermont Casting 33LDVR. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Vermont Casting 33LDVR ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.