Manuel d'utilisation / d'entretien du produit 3031 du fabricant Vermont Casting
Aller à la page of 26
Tested and listed to ANSI Z21.11.2a-2001, Unvented Heaters This is an unvented gas-fired heater. It uses air (Oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to Page 7. UVS27R, UVS27M V ent Free Gas Heaters Models 3030, 3031, 3032, 3033 20005004 10/04 Rev .
2 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Installation and Operating Instructions Shell Dimensions ............................................................................................................... 4 Clearance Requirements ..
3 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Installation & Operating Instructions In order to ensure safe and effective installation, this unit must be installed only by a qualified age.
4 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Shell Dimensions Drawing Not to Scale Fig. 1 UVS27 freestanding shell dimensions. C L C L 9" (229mm) 26 ³⁄₄ " (680mm) 25" (63.
5 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Hearth Requirements The Freestanding Stove and Hearthmount Shell must be installed on rigid flooring.
6 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Gas Specifications Max. Min. Input Input Mode l Fuel Gas Cont rol BT U /h BT U /h UVS27RN Nat Milli volt 2 8, 00 0 19,500 UVS27RP Prop Millivol t 28,000 19,500 UVS27MN Nat Millivolt 28,000 19,500 UVS27MP Prop Millivolt 28,000 19,500 Firebox weight / shipping 1 10 lbs.
7 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Pr ovide For Adequate V entilation Any space within a home can be classified in the following categories: 1) Unusually Tight Construction 2) Confined Space 3) Unconfined Space First, determine which classification defines the intended space.
8 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Example: A room that is 18' x 12' x 8' has a volume of 1728 cubic feet, ( length x width x height). An adjoining open kitchen that is 10' x 12' x 8' has a volume of 960 cubic feet.
9 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Assembly Procedures Refer to the specific assembly instructions for the shell appropriate to your UVS27R or UVS27M Heater installation.
10 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Screw & W asher Support Shelf Back Panel Side Plate ST106 Fig. 7 The sides must be at right angles to the back panel in order for the firebox to fit properly . ST125 Firebox washer align 10/15/99 djt Steel T ab Side Plate ST125 Fig.
11 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 ST346 Fig. 12 Attach snapstat to inner shroud. Rheostat Retaining Nut Control Knob FK104 Fig. 13 Attach rheostat to bracket. ST345 Fig. 11 Correct position of fan skirt installation. Install ON/OFF Switch The switch assembly parts are found in the parts bag.
12 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Glass & Catalyst Installation CA UTION: Air shutter on Natural Gas units must be adjusted when installing glass and catalyst for proper operation. LP units do not use an air shutter . 1. Remove screen.
13 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 90¡ Left Burner Leg Injector Orifices ST353a Fig. 20 Be sure injector orifices remain at 90 ° to the base. shoulders are inside the burner . 5. Replace rear , left and right log bracket assembly and replace logs.
14 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Install Log Set 1. Remove the logs from their packaging, and inspect each piece for damage. DO NO T INST ALL DAM- AGED LOGS. 2. Install the rear log by placing it on the sheet metal shelf at the back of the firebox.
15 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Complete the Installation 1. Install the screen frame by sliding the hooks over the top front edge of the firebox and resting the bottom on the support brackets.
16 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Operation Your First Fire Read these instructions carefully and familiarize yourself with the burner controls shown on Page 18. Locate the pilot assembly, Figure 28. Follow the lighting instructions on Page 17 exactly.
17 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 3. Open control access panel. 4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2.
18 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Tr oubleshooting Follow these procedures in the order presented. W ARNING TURN OFF HEA TER AND ALLO W T O COOL COMPLETEL Y BEFORE SER VICING. CONDITION POSSIBLE CAUSE SOLUTION No spark at pilot when Ignitor is operated.
19 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Tr oubleshooting cont’ d. CONDITION POSSIBLE CAUSE SOLUTION Pilot lights but flame goes out when Control Knob is released. 1. Control Knob not fully depressed or held in long enough. 2. Gas supply line shut-of f valve is not fully open.
20 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 The following procedures will help ensure that your heater continues to perform safely and efficiently. Firebox Cleaning and Inspection Cleanliness is critical to correct operation of the heater.
21 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Catalytic Combustor The combustor should be cleaned annually to ensure optimal performance. Follow the procedure below. Remove the Combustor Module 1. Be sure the heater is COLD. 2. Remove the top grille, screen and top plate.
22 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 PILO T O N O F F PILOT ADJ L O H I TPTH TH TP 1a 1b 1c 2a,b 6 8 5 21 19 20 4 11 12 13 7 15 9a,b 18 22 3 16a,b,c,d 10a 10b 14a,b 17 1d HI OFF PIL.
23 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 UVS27R, UVS27M V ent Free Gas Heater s Models 3030, 3031, 3032, 3033 (continued) Ref. Description UVS27 2a. Manifold Assy . - UVS27R 20003739 2b. Manifold Assy . - UVS27M 20004935 3. Damper Steel Handle/Screw (Stardance Operable Door Only) 5004265 4.
24 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 UVS27R, UVS27M V ent Free Gas Heater s Models 3030, 3031, 3032, 3033 (continued) Shell Enamel Part Numbers - Hearthmount Color T op Left End Rig.
25 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Optional Accessories A vailab le Fan Kits FK28 Fan Assemb ly The FK28 fan kit helps distribute heated air from within the firebox out into the room. The fan is controlled by a snapstat that turns power on and off as the firebox temperature rises above and falls below a preset temperature.
26 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 © CFM Specialty Home Products BASIC WARRANTY CFM Specialty Home Products (hereinafter referred to collectively as the Company) warrants that yo.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Vermont Casting 3031 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Vermont Casting 3031 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Vermont Casting 3031, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Vermont Casting 3031 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Vermont Casting 3031, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Vermont Casting 3031.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Vermont Casting 3031. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Vermont Casting 3031 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.