Manuel d'utilisation / d'entretien du produit VMH3000TNSA du fabricant Vanguard Heating
Aller à la page of 24
Save this manual for future reference. OWNER’S OPERA TION AND INST ALLA TION MANUAL VENT -FREE NA TURAL GAS MINI-HEAR TH ® HEA TER VMH3000TNSA 15,000 to 30,000 Btu/Hr with Thermostat This appliance ma y be installed in an aftermarket*, permanently located, manufac- tured (mobile) home, where not pr ohibited by state or local codes.
2 107101 NA TURAL GAS RESIDENTIAL HEA TERS ® For more information, visit www.desatech.com SAFETY INFORMA TION LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANS Z223.
3 107101 OWNER’S MANUAL For more information, visit www.desatech.com PRODUCT FEA TURES SAFETY DEVICE This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room heaters.
4 107101 NA TURAL GAS RESIDENTIAL HEA TERS ® For more information, visit www.desatech.com Truss-Head Screw Nut Front Panel Figure 4 - Attaching Brass Front Trim to Front Panel Brass Front Trim Figure.
5 107101 OWNER’S MANUAL For more information, visit www.desatech.com Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in.
6 107101 NA TURAL GAS RESIDENTIAL HEA TERS ® For more information, visit www.desatech.com DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space.
7 107101 OWNER’S MANUAL For more information, visit www.desatech.com VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space.
8 107101 NA TURAL GAS RESIDENTIAL HEA TERS ® For more information, visit www.desatech.com Figure 9 - Mounting Clearances As Viewed From Front of Heater CAUTION: If you install the heater in a home garage • heater pilot and burner must be at least 18 inches above floor.
9 107101 OWNER’S MANUAL For more information, visit www.desatech.com Thermostat Sensing Bulb Clamp THERMOSTAT SENSING BULB The thermostat sensing bulb has been placed inside the heater for protection during shipping. Locating Thermostat Sensing Bulb 1.
10 107101 NA TURAL GAS RESIDENTIAL HEA TERS ® For more information, visit www.desatech.com INST ALLA TION Continued Figure 12 - Folding Anchor Figure 13 - Popping Open Anchor Wings For Thin Walls Fig.
11 107101 OWNER’S MANUAL For more information, visit www.desatech.com INST ALLA TION Continued Continued Figure 16 - Attaching Heater to Hearth Base Figure 17 - Placing Hearth Insert on Heater Base and Attaching Brass Base Trim Mounting Heater to Optional Hearth Base 1.
12 107101 NA TURAL GAS RESIDENTIAL HEA TERS ® For more information, visit www.desatech.com INST ALLA TION Continued C. MOUNTING HEATER TO OPTIONAL MANTEL See Instructions Included With Mantel Kit Assembling Mantel IMPORTANT: Only use the optional man- tels specified in this manual.
13 107101 OWNER’S MANUAL For more information, visit www.desatech.com Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equip- ment shutoff valve from gas supply pip- ing system.
14 107101 NA TURAL GAS RESIDENTIAL HEA TERS ® For more information, visit www.desatech.com OPERA TING HEA TER TO TURN OFF GAS TO APPLIANCE Figure 22 - Pilot 7. Keep contr ol knob pressed in f or 30 seconds after lighting pilot. After 30 seconds, release contr ol knob .
15 107101 OWNER’S MANUAL For more information, visit www.desatech.com Thermocouple Thermocouple Pilot Burner Pilot Burner OPERA TING HEA TER Continued THERMOSTAT CONTROL OPERATION The thermostatic control used on this heater differs from standard thermostats.
16 107101 NA TURAL GAS RESIDENTIAL HEA TERS ® For more information, visit www.desatech.com TROUBLESHOOTING WARNING: Turn off and un- plug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater. REMEDY 1.
17 107101 OWNER’S MANUAL For more information, visit www.desatech.com REMEDY 1. Clean burner (see Cleaning and Mainte- nance , page 19) or replace burner orifice 2. Replace burner orifice 3. Contact local natural gas company 1. Contact local natural gas company 2.
18 107101 NA TURAL GAS RESIDENTIAL HEA TERS ® For more information, visit www.desatech.com TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
19 107101 OWNER’S MANUAL For more information, visit www.desatech.com CLEANING AND MAINTENANCE CABINET Air Passageways • Use a vacuum cleaner or pressurized air to clean. Exterior • Use a soft cloth dampened with a mild soap and water mixture. W ipe the cabi- net to remove dust.
20 107101 NA TURAL GAS RESIDENTIAL HEA TERS ® For more information, visit www.desatech.com ILLUSTRA TED PA R T S BREAKDOWN VMH3000TNSA 1 2 9 10 10 12 13 14 15 17 19 20 23 24 25 6 26 6 7 1 1 3 1 28 5 .
21 107101 OWNER’S MANUAL For more information, visit www.desatech.com P ARTS LIST VMH3000TNSA This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 19 of this manual.
22 107101 NA TURAL GAS RESIDENTIAL HEA TERS ® For more information, visit www.desatech.com TECHNICAL SER VICE You may have further questions about in- stallation, operation, or Trouble Shooting. If so, contact DESA International’s Techni- cal Service Department at 1-800-323-5190.
23 107101 OWNER’S MANUAL For more information, visit www.desatech.com PREMIER MANTEL Unfinished - GM903U Series Finished - GM902F Series White Lacquer Finish - GM904W (differs slightly from illustration) For use with heater. Features a built-in base.
KEEP THIS WARRANTY W ARRANTY INFORMA TION Model ________________________________ Serial No. _____________________________ Date Purchased ________________________ Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Vanguard Heating VMH3000TNSA c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Vanguard Heating VMH3000TNSA - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Vanguard Heating VMH3000TNSA, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Vanguard Heating VMH3000TNSA va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Vanguard Heating VMH3000TNSA, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Vanguard Heating VMH3000TNSA.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Vanguard Heating VMH3000TNSA. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Vanguard Heating VMH3000TNSA ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.