ELECTRONIC AIR CLEANER LIMITED THREE-YEAR W ARRANTY This limited warranty covers T rion Residential T ype Electronic Air Cleaners, excluding ductwork, wiring and installation. T rion warrants that all new T rion Electronic Residential Air Cleaners are free from defects in material and workmanship under normal, noncommercial use and service.
Power T ray Assembly 120/50-60/1 Power T ray Assembly 240/50-60/1 High Frequency Power Supply* Electronic Air Flow Sensor* On/Off switch* Interlock Switch* Cabinet Assembly Pre-Filter (2 req.) Cell, Ionizing-Collecting (2 req.) Ionizing Wire Assembly Front Panel Assembly Contact Board Assembly (2 req.
10. If no voltage is present, remove the second cell. Install cell number one and measure voltage as described in step #7. If voltage is present, the second cell, which is now out of the cabinet, is shorted. Refer to COMMON TROUBLESHOOTING TECHNIQUES (pg.
SECONDAR Y CIRCUIT POWER SUPPL Y If the Red CELL ENERGIZED light remains out with the Ionizing-Collecting Cells removed from the cabinet, the power supply is defective. Specific problems in the Power T ray Assembly can be isolated by using a Multimeter and High V oltage Probe to check the output voltages.
SECONDAR Y CIRCUIT IONIZING-COLLECTING CELL The cells are electrically energized through a contact terminal located at the top center of each cell. The ionizing wires and alternating collector plates are electrically charged while the interleaving plates are grounded.
PRIMAR Y CIRCUIT WITH HV AC SYSTEM BLOWER OPERA TING • If there is no supply line voltage at the transformer input connections, correct the fault at the dedicated power source or HV AC system power source.
TROUBLESHOOTING W ARNING: • These procedures must be performed by a qualified HV AC technician or electrician. • Risk of personal injury or death could occur by attempting to troubleshoot or r epair this unit by untrained persons. • Exercise the usual pr ecautions when working with high voltage.
SYSTEM CHECKOUT W ARNING: The following procedur es must be conducted by a qualified HV AC contractor or repair person ONL Y . These procedur es will expose hazardous electrically energized charged components. Disconnect power between checks and proceed car efully .
ELECTRICAL INST ALLA TION CAUTION : If the Electronic Air Cleaner is wir ed directly to the integrated accessory control on the furnace, it is imperative that the ampere rating of the contr ol be sufficient to handle the curr ent requir ed by the air cleaner .
NOTE: The following is a typical installation of the air cleaner on a highboy furnace. Y ou may have to alter the installation to fit your particular application. 1. Locate the cabinet in the cold air return duct such that all of the return air flows through the unit.
INST ALLA TION CAUTION: Only a trained, experienced servicer should install this Electronic Air Cleaner . The Front Panel Assembly , Power T ray Assembly , Ionizing-Collecting Cells and Pre-filters should be r emoved befor e installation. T o remove the Power T ray Assembly , remove the two (2) screws fr om inside the top front of the cabinet.
Installation 15 EAC20002025 EAC14001625 EAC14002020 Unit Dimensions 10 For Qualified HV AC Installer Only TYPICAL MOUNTING POSITIONS (Air cleaner shown shaded in illustrations) Horizontal Furnace – Mounted vertically in return duct as close to the furnace as possible.
LOCA TION SELECTION Remember to select a location that is readily accessible for periodic inspection and cleaning of the the Pre- filters and Ionizing-Collecting Cells. Allow a minimum of 24” clearance in front and 12” clearance above the air cleaner for component removal and service space.
Atomizing Humidifiers If an atomizing humidifier is mounted upstream of the air cleaner: 1. Mount the humidifier as far upstream in the ductwork as possible. A distance of at least 10 feet is recommended to reduce the possibility of excessive arcing as water droplets pass through the Electronic Air Cleaner .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Trion HE Plus 2000 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Trion HE Plus 2000 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Trion HE Plus 2000, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Trion HE Plus 2000 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Trion HE Plus 2000, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Trion HE Plus 2000.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Trion HE Plus 2000. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Trion HE Plus 2000 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.