Air Boss MP 600M Vertical Air Flow Mist Precipitator Installation Operation Service Please read these instructions carefully for trouble free operation and to get the mo st out of your purchase. For further info rmation concern ing this pro ject, con tact your local Tr ion representative.
2 DESCRIPTION The Trion MP 600M air cleane r is designed to capture machine tool fluids, metal dust and sm oke for clean air filtration. It can be mounted to a wall, frame, platfo rm, or directly on the machine tool. Mist, dust, and smoke are drawn from each machine through an external duct into the air cleaner.
3 Figure 1 - MP 600M High Static SPECIFICATIONS STANDARD OPTIONAL MP600M and High Static MP 600M Voltage 115 208-230 208-230/460 575 115/230 Phase 1 1 3 3 1 HZ 60 60 60 60 60 AMPS 17 9.4-8.5 4.9-4.6/2.3 1.9 8.0-4.0 Motor ½ hp 1 ½ hp 1 ½ hp 1 ½ hp ½ hp CFM 600 600 600 600 600 Shipping Weight 175 lbs 225 lbs.
4 Figure 2 – Dimension and Access Data GENERAL SAFETY INFORMATION WARNING: RISK OF ELECTRIC SHOCK These serving instruction s are for use by qualified personnel only, To redu ce the risk of electric shock, do not perform any servicing ot her than that contained in the operating instructions unl ess you are qualified to do so.
5 CAUTION: When using flex duct connections with other than straight runs of duct, 45 degree elbows shoul d be used to connect ducting to flang ed collars to maximize air flow.
6 Figure 4 - MP 600M Inlet Plenum and Stand Options.
7 Figure 5 – Wiring Diagrams for Model MP 600M.
8 Figure 6 – Wiring Diagram.
9 Figure 6A – Motor Wiring Diagram.
10 The MP600M is wired directly from the power source with 20 amps minimum, se rvice utilizing 3 wire grounded cable, (115-208-2 30-460-575/60/3) for single 208- 230/60/1, phase service and 4 wi re grounded cable for 3 phase service, routed through ap propriate conduit (See figure 5 wiring diagram).
11 A. Thoroughly inspect the main and pre- filter for holes, tears or any other condition that might allow air to leak through or around the filter. Re place the filters if any damage is found. B. Inspect the cabinet. Remove all foreign debris and dirt accumulation insi de the cabinet.
12 Figure 7 – MP 600M Unit Assembly.
13 Figure 7A – Unit Assembly Parts List MP 600M MP 600M HS Qty Qty Item Part No. Description Rem arks 1 1 1 353613-001 Cabinet Assembly 1 1 2 354477-001 Access Door 1 1 3 253619-001 Blower Housing C.
14 Figure 8 – Filter Locking Mechanism - Access opening increased 3.5 ” height - 16 GA tapered filter retainer welded in door and ca binet rear - As door closes, filter gasket is compre ssed and s.
15 Figure 9 – System Performance Curv es (without Filters) Flow – CFM @ 60 Hz Added Static @ Filter 600 CFM 1000 m 3 /hr Filter Inches W.C. Pascals 99.97% DOP HEPA 1.00 250 95% DOP 0.35 87 90-95% ASHRAE 0.20 50 80-85% ASHRAE 0.15 37 60-65% ASHRAE 0.
WARRANTY All Trion air cleaners are warranted fo r component failure and workmanship for a period of three years after purchase. Do not return defective pa rts without prior permission from the factory.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Trion 600M c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Trion 600M - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Trion 600M, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Trion 600M va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Trion 600M, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Trion 600M.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Trion 600M. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Trion 600M ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.