Manuel d'utilisation / d'entretien du produit TAM7B0C60H51SA du fabricant Trane
Aller à la page of 28
V ariab le Speed Modular Multi-position Air Handler s 2-5 T ons T AM7A0A24H21SB T AM7A0B30H21SB T AM7A0C36H31SB T AM7A0C42H31SB PUB. NO . 22-1847-03 T AM7A0C48H41SB T AM7A0C60H51SB T AM7B0C60H51SA.
2 Pub . No . 22-1847-03 Featur es and Benefits © 2012 T rane • Unique cabinet design – 2% or less air leakage – Precision applied - durab le door seals – Specially designed air seal around refrigerant, condensate and conduit connections – Double w all f oamed cabinet system – R-4.
Pub . No . 22-1847-03 3 Contents Features and Benefits 2 Optional Equipment 4 Unique Cabinet Design Features and Benets 5 General Data 6 T AM7A0A24H21SB 6 T AM7A0B30H21SB 6 T AM7A0C36H31SB 6 T AM7.
4 Pub . No . 22-1847-03 Optional Equipment Accessory Number Description Fits Cabinet Size BA YEV AC05BK1AA Electric Heater , 5kW , Breaker , RS-485 Control, 1 Ph A to C BA YEV AC05LG1AA Electric Heate.
Pub . No . 22-1847-03 5 5 Conduit Connections Locations r Integrated Horizontal Drain P ans 6 T ool-less Door Fastener s 7 Alert Code Viewport e Compact 20.
6 Pub . No . 22-1847-03 General Data PRODUCT SPECIFICA TIONS MODEL T AM7A0A24H21SB RA TED V OL TS/PH/HZ. 200-230/1/60 RA TINGS 1 See O .D . Specications INDOOR COIL — T ype Plate Fin Rows — F .P .I. 3 - 14 F ace Area (sq. ft.) 3.67 T ube Size (in.
Pub . No . 22-1847-03 7 T AM7A0A24 AIRFLO W PERFORMANCE CONST ANT CFM MODE / CONST ANT TORQ UE MODE OUTDOOR MUL TIPLIER (T ONS) COOLING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE HEA TING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE 0.
8 Pub . No . 22-1847-03 T AM7A0B30 AIRFLO W PERFORMANCE CONST ANT CFM MODE / CONST ANT TORQ UE MODE OUTDOOR MUL TIPLIER (T ONS) COOLING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE HEA TING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE 0.
Pub . No . 22-1847-03 9 T AM7A0C36 AIRFLO W PERFORMANCE CONST ANT CFM MODE / CONST ANT TORQ UE MODE OUTDOOR MUL TIPLIER (T ONS) COOLING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE HEA TING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE 0.
10 Pub . No . 22-1847-03 Minimum Heating Airo w Settings T AM7A0C42 AIRFLO W PERFORMANCE CONST ANT CFM MODE / CONST ANT TORQ UE MODE OUTDOOR MUL TIPLIER (T ONS) COOLING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE HEA TING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE 0.
Pub . No . 22-1847-03 11 Minimum Heating Airo w Settings T AM7A0C48 AIRFLO W PERFORMANCE CONST ANT CFM MODE / CONST ANT TORQ UE MODE OUTDOOR MUL TIPLIER (T ONS) COOLING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE HEA TING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE 0.
12 Pub . No . 22-1847-03 Minimum Heating Airo w Settings T AM7A0C60H51SB, T AM7B0C60H51SA AIRFLO W PERFORMANCE CONST ANT CFM MODE / CONST ANT TORQ UE MODE OUTDOOR MUL TIPLIER (T ONS) COOLING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE HEA TING AIRFLOW SETTING Airow Po we r EXTERNAL ST A TIC PRESSURE 0.
Pub . No . 22-1847-03 13 Electrical Data Notes: 1. See Air Handler nameplate for appro ved combinations of Air Handlers and Heaters 2. Heater model numbers may ha v e additional sufx digits. kW BTUH kW BTUH No Heater 0 - - 3.0** 4 15 - - 3.0** 4 15 BAYEVAC05++1 1 4.
14 Pub . No . 22-1847-03 Electrical Data kW BTUH kW BTUH No Heater 0 - - 3.0** 4 15 - - 3.0** 4 15 BAYEVAC05++1 1 4.80 16400 20.0 29 30 3.60 12300 17.3 25 25 BAYEVAC08++1 1 7.68 26200 32.0 44 45 5.76 19700 27.7 38 40 BAYEVAC10++1 1 9.60 32800 40.0 54 60 7.
Pub . No . 22-1847-03 15 Electrical Data kW BTUH kW BTUH No Heater 0 - - 4.2** 5 15 - - 4.2** 5 15 BAYEVAC05++1 1 4.80 16400 20.0 30 30 3.60 12300 17.3 27 30 BAYEVAC08++1 1 7.68 26200 32.0 45 45 5.76 19700 27.7 40 40 BAYEVAC10++1 1 9.60 32800 40.0 55 60 7.
16 Pub . No . 22-1847-03 Electrical Data kW BTUH kW BTUH No Heater 0 - - 5.5** 7 15 - - 5.5** 7 15 BAYEVAC05++1 1 4.80 16400 20.0 30 30 3.60 12300 17.3 27 30 BAYEVAC08++1 1 7.68 26200 32.0 45 45 5.76 19700 27.7 40 40 BAYEVAC10++1 1 9.60 32800 40.0 55 60 7.
Pub . No . 22-1847-03 17 AIR HANDLER ELECTRIC HEA TER PRESSURE DROP Air handler electric heater pressure drop is negligib le f or the heaters and is inc luded in the airow data f or the Series 7 air handler s.
18 Pub . No . 22-1847-03 T AM7 AIR HANDLER AND HEA TER MA TRIX - ALLO WBLE COMBINA TIONS Electrical Data AIR HANDLER MODEL NUMBER AC05BK1AA 4.80 Kw BK AC05LG1AA 4.80 Kw LG AC08BK1AA 7.68 Kw BK AC08LG1AA 7.68 Kw LG AC10BK1AA 9.60 Kw BK AC10LG1AA 9.60 Kw LG BC15BK1AA 14.
Pub . No . 22-1847-03 19 Electrical Data WIRING DIA GRAM FOR T AM7 AIR HANDLERS.
20 Pub . No . 22-1847-03 Comfort Control Air Handler Air Conditioner Neatly bundle all low voltage wires behind the service valve cover as shown. Field wiring Y ellow Blue Red Y ellow Green White Blue.
Pub . No . 22-1847-03 21 Comfort Control Air Handler Heat Pump Neatly bundle all low voltage wires behind the service valve cover as shown. Field wiring Y ellow Blue Black (X2) Red Orange Red Y ellow .
22 Pub . No . 22-1847-03 T wo Stage Cooling Field Wiring Comfort Control Air Handler Air Conditioner Neatly bundle all low voltage wires behind the service valve cover as shown.
Pub . No . 22-1847-03 23 Comfort Control Air Handler Heat Pump Neatly bundle all low voltage wires behind the service valve cover as shown. Y ellow/Red Field wiring Y ellow Blue Black (X2) Red Orange .
24 Pub . No . 22-1847-03 T AM7 Conver tibility Multi-position Air Handler Airflow Airflow Airflow Airflow Upflow Condensate Drains Refrigerant Connections Downflo w Condensate Drains Refrigerant Conne.
Pub . No . 22-1847-03 25 Dimensions T AM7 AIR HANDLER DIMENSIONAL D A T A T AM7 AIR HANDLERS ARE ALL TWO PIECE CABINETS. Model No . H W D T AM7A0A24H21SB 49.9 17.5 21.75 T AM7A0B30H21SB 55.7 21.3 21.75 T AM7A0C36H31SB 56.9 23.5 21.75 T AM7A0C42H31SB 56.
26 Pub . No . 22-1847-03 T AM7 OUTLINE DRA WING MODEL NO . A B C D E F H FLO W CONTROL GAS LINE BRAZE LIQ LINE BRAZE T AM7A0A24H21SB 49.9 17.5 14.5 39.6 14.5 7.3 24.4 EEV 3/4 3/8 T AM7A0B30H21SB 55.7 21.3 18.4 45.5 18.4 9.2 24.8 EEV 3/4 3/8 T AM7A0C36H31SB 56.
Pub . No . 22-1847-03 27.
T rane 6200 T roup Highway T yler , TX 75707 www .trane.com 03/12 The manuf acturer has a policy of continuous product and product data improv ement and it reserves the right to change design and specifications without notice.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Trane TAM7B0C60H51SA c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Trane TAM7B0C60H51SA - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Trane TAM7B0C60H51SA, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Trane TAM7B0C60H51SA va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Trane TAM7B0C60H51SA, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Trane TAM7B0C60H51SA.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Trane TAM7B0C60H51SA. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Trane TAM7B0C60H51SA ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.