Manuel d'utilisation / d'entretien du produit Model 7505 du fabricant Beckett
Aller à la page of 12
Description / Applications The Beckett GeniSys TM Advanced Burner Control is a 120 V ac primary safety control for residential and light commercial oil burners used in boiler , furnace, and water heater applications having fi ring rates less than 20 GPH.
2 T able 1 - Models and Cross Reference Guide Beckett GeniSys Control Part No. Lockout Time V alve-on delay time 2 Motor-off delay time 2 Replaces Honeywell: Replaces Carlin: 7505A 0000 15 sec - - R71.
3 120v GeniSys Control Installation and Operation Manual Optional Snap-on Display Module: For programming and diagnostics Optional Snap-on Alarm Module: For adding isolated low voltage alarm contacts to the base control. See Alarm Module Instructions for speci fi cations.
4 Electrical Ratings Inputs: V oltage: 120 V ac nominal (102 to 132 V ac) Current: 100 mA nominal (150 mA max at 132 V ac) Frequency: 60 Hz Outputs: Motor: 120 V ac, 10 full load amps (FLA), 60 locked rotor amps (LRA) *Note: Reduce motor FLA rating by igniter current Igniter: 120 V ac, 3 A @ 0.
5 120v GeniSys Control Installation and Operation Manual The control can malfunction if it gets wet, leading to accumulation of oil or explosive oil vapors. Never install where water can fl ood, drip or condense on the control. Never use a control that has been wet - replace it.
6 Figure 3 – 7505A (for replacement of R7184A) Interrupted ignition, no valve-on or motor-off delay ► Figure 4 – 7505B (for replacement of R7184B) Interrupted ignition, valve-on delay only (no m.
7 120v GeniSys Control Installation and Operation Manual T ypical Furnace Wiring: Figure 6 – 7505A (for replacement of R8184G) Intermittent ignition, no valve-on or motor-off delays ► SAFETY AND O.
8 Star tup / Check out If the burner or control fails any of the following tests, recheck control wiring. If the burner or control still fails any tests, replace the control. Starting the System Open the shut-off valves in the supply line from the oil tank.
9 120v GeniSys Control Installation and Operation Manual 2 1 3 5 6 8 4 7 Standby Motor-off delay V alve-on delay T rial for ignition Ignition carryover Run Lockout Recycle 9 Pump prime is then sent to Motor-Off Delay , if applicable, or it is shut down and sent to Standby .
10 If the burner is in the below state: Pushing the reset button will: Button Click (press < 1 second) Button Hold (press > 1 second) Button Hold (press 15+ seconds) Lockout Reset from Soft Lock.
11 120v GeniSys Control Installation and Operation Manual automatically return to standby mode . If prime is not established during the four minute pump prime mode, return to step 5 to re-enter Pump Prime mode. Repeat steps 5 through 7 until the pump is fully primed and the oil is free of bubbles.
Form No. 61649 R14, Printed in USA 10/10 CORPORA TION USA: P.O. Box 1289 ● Elyria, OH 44036 Canada: R.W. Beckett Canada, Ltd. ● Unit #3, 430 Laird Road ● Guelph, Ontario N1G 3X7 www.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Beckett Model 7505 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Beckett Model 7505 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Beckett Model 7505, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Beckett Model 7505 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Beckett Model 7505, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Beckett Model 7505.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Beckett Model 7505. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Beckett Model 7505 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.