1 Form 6104 BCF23-R05 Potential for Fire, Smoke and Asphyxiation Hazards T o the Homeowner or Equipment Owner: Please read and carefully follow all instructions pro- vided in this manual regarding your responsibilities in caring for your heating equipment.
2 Form 6104 BCF23-R05 T able of Contents General Information ............................................................................................................................. 3-4 T o the Owner ..............................................
3 Form 6104 BCF23-R05 Bef or e you begin . . . The following resources will give you addional information for your installation. W e suggest that you consult these resources whenever possible. Pay particular attention to the appliance manufacturer ’ s instructions.
4 Form 6104 BCF23-R05 Please read all instructions before proceeding. Follow all instructions completely . This equipment must be installed, adjusted and started by a quali fi ed service agency that is licensed and experienced with all applicable codes and ordinances and responsible for the installation and commission of the equipment.
5 Form 6104 BCF23-R05 Nozzle pr essure The fuel unit nozzle port pressure is factory set at 300 psig. Some original equipment manufacturer burner applications may call for a lower pressure to obtain a required fi ring rate. Do not change this pressure un- less directed to do so by the appliance manufacturer .
6 Form 6104 BCF23-R05 V ent system The fl ue gas venting system must be in good condition and must comply with all applicable codes. V erify bur ner components — Burner box, Model CF1400 or CF2300A.
7 Form 6104 BCF23-R05 V erify air tube The information in this section may be disregarded if the air tube is supplied by the appliance manufacturer. On the CF1400 , there are two tube arrangements available – T ube A — 4.0 to 1 1.0 GPH per T able 2 T ube B — 7.
8 Form 6104 BCF23-R05 This burner is designed for clean, dry installations. Electrical controls are not protected against rain or sprayed water . Keep the installation clear of dust, dirt, corrosive vapors, and moisture. Protective covers and more frequent maintenance may be required.
9 Form 6104 BCF23-R05 Mount air tube to bur ner Remove the rear access door from the back of the burner for improved access to the interior . Attach the air tube to the burner with the bolts and acorn nuts provided. The acorn nuts must go on the outside of the burner , with the bolts inserted from the inside.
10 Form 6104 BCF23-R05 Figure 6 – Nozzle line assembly in burner Z 2308 a Measure dimension from front (flat) face of head to end of air tube, as shown.
11 Form 6104 BCF23-R05 Figure 8 – Burner installed in appliance front Dimension CF 1400 CF 2300 H 18” 18-1/2” J 10-7/8” 10-1/2” K 13-5/8 15-5/8” Inser t bur ner Position the burner in the front of the appliance and loosely tighten the nuts on the mounting studs.
12 Form 6104 BCF23-R05 Models CF1400 and CF2300 are shipped with the pump bypass plug installed. Do not remove the bypass plug from the pump. It is required for step- fi ring (Lo/Hi) operation. Do not operate the burner unless a return line or bypass loop is installed or the pump seal will rupture.
13 Form 6104 BCF23-R05 Figure 9 – One-pipe oil fl ow with “B” pump 300 psig high fi re 125 to 175 psig low fire 2320a d c c b m a g f p h Fie ld-installe d by-pass loop Figure 10 – T wo-pipe .
14 Form 6104 BCF23-R05 W ir e the bur ner — R7184B Install the burner and all wiring in accordance with the National Electrical Code and all applicable local codes or requirements. W ire the burner in compliance with all instructions provided by the appliance manufacturer .
15 Form 6104 BCF23-R05 Standby T rial for T rial for ignition Lockout Recycle Run 3 4 Ignition carryover Motor -off delay (postpurge) 8 6 7 5 V alve-on delay 2 1 Sequence of oper a tion — typical Install the burner and all wiring in accordance with the National Electrical Code and all applicable local codes or requirements.
16 Form 6104 BCF23-R05 Start-up checklist – Verify the following before at- tempting to start burner. Combustion air supply and venting have been inspected and veri fi ed to be free of obstructions and installed in accordance with all applicable codes.
17 Form 6104 BCF23-R05 T able 4a. CF1400 Initial indicator adjustment plate settings Figure 12 – Adjusting plate initial setting, typical T able 4b. CF2300 Initial indicator adjustment plate settings CF1400 T ube Head Position Damper Position Approximate Head Setting Firing Rate (gph) Approximate Air Damper Setting Firing Rate (gph) A 0 4.
18 Form 6104 BCF23-R05 Initial air settings The following steps outline the procedure for initially setting the damper . Refer to Figures 13A and 13B and T ables 4a or 4b for this procedure. 1. Remove the cover screw ( A ) then the cover ( B ) and place to one side.
19 Form 6104 BCF23-R05 Star t the bur ner Please read and understand the manual supplied with this equipment. This equipment must be installed, adjusted and put into operation only by a quali fi ed individual or service agency that is: Licensed or certi fi ed to install and provide technical service to oil heating systems.
20 Form 6104 BCF23-R05 Star t bur ner and vent air from oil line Move the low- fi re hold switch to the low fi re hold position (to hold burner in low fi re when started). V erify that the air adjusting cam ( Figure 13b , item d ) has been set to the initial low- fi re air setting as described under Initial air settings.
21 Form 6104 BCF23-R05 Annual Service Replace the oil supply line fi lter . The line fi lter cartridge must be replaced to avoid contamination of the fuel unit and nozzle. Inspect the oil supply system. All fi ttings should be leak-tight. The supply lines should be free of water , sludge and other restrictions.
22 Form 6104 BCF23-R05 R eplacement P ar ts For best performance specify genuine Beckett replacement parts Item Part Name Description Part No. 1 T imer Nozzle valve delay 21295U 2 Oil V alve Box mount.
23 Form 6104 BCF23-R05 Figure 15 – Adjustable mounting plates Model Flange A Flange B Flange C CF1400 51312 (10.00” DIA.) n/a 51629 (12.25” DIA.) CF2300 51313 (12.
24 Form 6104 BCF23-R05 Limited WARRANTY For Residential, Commercial and Specialty Burners The R. W. BECKETT CORPORATION (“Beckett”) warrants to persons who purchase its Beckett burners from Becket.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Beckett CF2300 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Beckett CF2300 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Beckett CF2300, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Beckett CF2300 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Beckett CF2300, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Beckett CF2300.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Beckett CF2300. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Beckett CF2300 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.