2500/3500 MODEL MODEL MODEL MODEL MODEL CF CF 2500/ 3500 Instruction M anual Oil Burner Thank you for purchasing a Beckett burner . With proper care and regular maintenance, it will provide years of trouble-free service. Please take a few minutes to read the section entitled “T o the owner” inside this manual.
Instruction Manual – Model CF2500/CF3500 Oil Burner 2 Form 6104 BCF-35-R0699 Please . . . r ead this page first Denotes presence of a hazard which, if ignored, could result in minor personal injury or property damage.
Instruction Manual – Model CF2500/CF3500 Oil Burner 3 Form 6104 BCF-35-R0699 W arranty Beckett warrants its equipment to those who have purchased it for resale, including your dealer . If you have an y problems with your equipment or its installation, you should contact your dealer for assistance.
Instruction Manual – Model CF2500/CF3500 Oil Burner 4 Form 6104 BCF-35-R0699 Pr e-installation checklist T able 1 – Nozzle capacities at various pressures ❏ Combustion air supply • The burner requires combustion air and ventilation air for reliable operation.
Instruction Manual – Model CF2500/CF3500 Oil Burner 5 Form 6104 BCF-35-R0699 3502 E D G F T 2 ° 1 T able 2 – Air tube capacity vs. firebox pressure Figure 2 – Air tube mounting dimensions E Insertion depth G Air tube to inside of chamber – 0.
Instruction Manual – Model CF2500/CF3500 Oil Burner 6 Form 6104 BCF-35-R0699 Mount the bur ner ❏ Mount flange(s) on air tube • This section does not apply to burners with welded flanges. • Do not install air tube on burner . • For non-pressure firing flange , refer to Figure 3 : Install gasket (item a ) and flange (item d ).
Instruction Manual – Model CF2500/CF3500 Oil Burner 7 Form 6104 BCF-35-R0699 Z 3506 a Measure dimension from front (flat) face of head to end of air tube, as sho wn.
Instruction Manual – Model CF2500/CF3500 Oil Burner 8 Form 6104 BCF-35-R0699 Connect fuel line(s) ❏ Fuel unit by-pass plug The CF2500A, CF2500 and CF3500A burners are shipped without the by-pass plug installed. Y ou must install this plug on tw o- pipe systems.
Instruction Manual – Model CF2500/CF3500 Oil Burner 9 Form 6104 BCF-35-R0699 Figure 9a T wo-pipe oil flow , one nozzle, low fire, “ H ” pump • Install two high-quality shutoff valves in accessible loca- tions on the oil supply line. Locate one valve close to the tank.
Instruction Manual – Model CF2500/CF3500 Oil Burner 10 Form 6104 BCF-35-R0699 Wir e the bur ner Install the burner and all wiring in accordance with the National Electrical Code and all applicable local codes or requirements. W ire the burner in compliance with all instructions pro vided by the appliance manufacturer .
Instruction Manual – Model CF2500/CF3500 Oil Burner 11 Form 6104 BCF-35-R0699 Sequence of operation — typical 1. On call for heat from the appliance operating controls (and the circuit from T to T of the R8184 closed), power is applied to the R8184 black wire ( BK ).
Instruction Manual – Model CF2500/CF3500 Oil Burner 12 Form 6104 BCF-35-R0699 Pr epar e the bur ner for star t-up - continued ❏ Z dimension • Should be set per these instructions (see page 7). The top acorn nut ( Figure 11 , item d ) should never be loosened once the Z dimension is initially set.
Instruction Manual – Model CF2500/CF3500 Oil Burner 13 Form 6104 BCF-35-R0699 T able 5 – Initial air adjusting plate settings (damper position) Figure 12 – Air damper and damper motor assembly L.
Instruction Manual – Model CF2500/CF3500 Oil Burner 14 Form 6104 BCF-35-R0699 Star t the bur ner Do not proceed unless all prior steps in this manual have been completed. Failure to comply could result in sev ere personal injury , death or substantial property damage.
Instruction Manual – Model CF2500/CF3500 Oil Burner 15 Form 6104 BCF-35-R0699 Maintenance and ser vice Annual service — by qualified service technician Have the burner inspected, tested and started at least annually by a qualified service technician.
Instruction Manual – Model CF2500/CF3500 Oil Burner Form 6104 BCF-35-R0699 U.S.A.: P . O. Box 1289 • Elyria, Ohio 44036 • 800-645-2876 • 440-327-1060 • F AX 440-327-1064 Canada: R.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Beckett CF 2500/ 3500 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Beckett CF 2500/ 3500 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Beckett CF 2500/ 3500, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Beckett CF 2500/ 3500 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Beckett CF 2500/ 3500, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Beckett CF 2500/ 3500.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Beckett CF 2500/ 3500. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Beckett CF 2500/ 3500 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.