Manuel d'utilisation / d'entretien du produit CF 2300A du fabricant Beckett
Aller à la page of 16
23 0 0 MODEL MODEL MODEL MODEL MODEL CF 2300A Instruction M anual Oil Burner Thank you for purchasing a Beckett burner . With proper care and regular maintenance, it will provide years of trouble-free service. Please take a few minutes to read the section entitled “T o the owner” inside this manual.
Instruction Manual – Model CF2300A Oil Burner 2 Form 6104 BCF-23-R0399 Please . . . r ead this page first Denotes presence of a hazard which, if ignored, could result in minor personal injury or property damage.
Instruction Manual – Model CF2300A Oil Burner 3 Form 6104 BCF-23-R0399 W arranty Beckett warrants its equipment to those who have purchased it for resale, including your dealer . If you hav e any problems with your equipment or its installation, you should contact your dealer for assistance.
Instruction Manual – Model CF2300A Oil Burner 4 Form 6104 BCF-23-R0399 Pr e-installation checklist T able 1 – Nozzle capacities at various pressures ❏ Combustion air supply • The burner requires combustion air and ventilation air for reliable operation.
Instruction Manual – Model CF2300A Oil Burner 5 Form 6104 BCF-23-R0399 T able 2 – Air tube capacity vs. firebox pressure Figure 2 – Air tube mounting dimensions 2304 E D G T 2° 1 F E Insertion depth G Air tube to inside of chamber – 0.25" ± 0.
Instruction Manual – Model CF2300A Oil Burner 6 Form 6104 BCF-23-R0399 Mount the bur ner ❏ Mount flange(s) on air tube • This section does not apply to burners with welded flanges. • Do not install air tube on burner . • For non-pressure firing flange , refer to Figure 3 : Install gasket (item a ) and flange (item d ).
Instruction Manual – Model CF2300A Oil Burner 7 Form 6104 BCF-23-R0399 Figure 5 – Nozzle line assembly in burner ❏ ❏ ❏ ❏ ❏ Set dimension Z • Replace the rear access door on the bu rner , making sure that the adjust- ing plate assembly is now securely held in place.
Instruction Manual – Model CF2300A Oil Burner 8 Form 6104 BCF-23-R0399 Connect fuel line(s) ❏ Fuel unit by-pass plug • The CF2300A burner is shipped with a by-pass plug in- stalled in the fuel unit.
Instruction Manual – Model CF2300A Oil Burner 9 Form 6104 BCF-23-R0399 Figure 9a – T wo-pipe oil flow , low fire, “ H ” pump • Use continuous lengths of heavy-wall copper tubing, routed under the floor where possible. Do not attach fuel lines to the appliance or to floor joists if possible.
Instruction Manual – Model CF2300A Oil Burner 10 Form 6104 BCF-23-R0399 Legend FD Fused disconnect, by others LM Limit controls, by others OP Operating controls, by others PR Oil primary control, R8.
Instruction Manual – Model CF2300A Oil Burner 11 Form 6104 BCF-23-R0399 Sequence of operation — typical NO TE: The following sequence is based on using a type B fuel unit, with pump-mounted by-pass valve. The by-pass valve operation is reversed for a type H fuel unit.
Instruction Manual – Model CF2300A Oil Burner 12 Form 6104 BCF-23-R0399 Pr epar e the bur ner for star t-up - continued ❏ Z dimension • Should be set per these instructions (see page 7). The top acorn nut ( Figure 11 , item d ) should never be loosened once the Z dimension is initially set.
Instruction Manual – Model CF2300A Oil Burner 13 Form 6104 BCF-23-R0399 T able 5 – Initial air adjusting plate settings (damper position) CLOSE OPEN 2309-1 a b d e f g Figure 12 – Air damper and.
Instruction Manual – Model CF2300A Oil Burner 14 Form 6104 BCF-23-R0399 Star t the bur ner Do not proceed unless all prior steps in this manual have been completed. Failure to comply could result in se v ere personal injury , death or substantial property damage.
Instruction Manual – Model CF2300A Oil Burner 15 Form 6104 BCF-23-R0399 Maintenance and ser vice Annual service — by qualified service technician Have the burner inspected, tested and started at least annually by a qualified service technician. This annual test/inspection should include at least the following: ❏ Replace oil nozzle.
Instruction Manual – Model CF2300A Oil Burner Form 6104 BCF-23-R0399 U.S.A.: P . O. Box 1289 • Elyria, Ohio 44036 • 800-645-2876 • 440-327-1060 • F AX 440-327-1064 Canada: R.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Beckett CF 2300A c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Beckett CF 2300A - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Beckett CF 2300A, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Beckett CF 2300A va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Beckett CF 2300A, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Beckett CF 2300A.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Beckett CF 2300A. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Beckett CF 2300A ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.