Manuel d'utilisation / d'entretien du produit PRDS48 du fabricant Thermador
Aller à la page of 28
Th dor ® CORPORATION 6D 00 INSTALLATION INSTRUCTIONS MANUAL PROFESSIONAL RANGES ALL-GAS MODELS - PRG304, PRG36 ANqTPRG48. DUAL-FUEL MODELS - PRDS304, PRDS36 AND~PRDS48 PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORTANT: LOCAL CODES VARY. INSTALLATION, ELECTRICAL CONNECTIONS, GAS CONNECTIONS.
IMPORTANT INSTALLATION INFORMATION INTRODUCTION The Thermador Professional* Ranges are free standing units available in a number of configura tions. Model PRG304 is equipped with four sealed gas surface burn ers, a large capacity gas oven with gas infra-red broiler and convection system.
Thermadar AVERTISSEMENTS EN FRANCAIS ® CORPORATION For Residential Use Only ALL-GAS MODELS - PRG304 AND PRG36, DUAL FUEL MODELS PRDS304, PRDS36 AND PRDS48 CET MAN U EL CONTEN IT AVERTISSEMENTS EN FRANCAIS AVERTISSEMENT: Couper le courant avant d'installer.
AVERTISSEMENTS EN FRANCAIS s ADVEHnBfflJVIENlY • TOUTESLESCUISINIERES PEUVENTRENVERSER • LESBLESSURESAUX PERSONNES PEUVENT R&ULTER • INSTALLER L'APPAREIL ANTl-RENVERSER EMALLE AVEC LA C.
IMPORTANT INSTALLATION INFORMATION /^IMPORTANT: All ranges must be installed with a backguard. Models PRG304 and PRDS304 are shipped from the factory with a standard 9" back- guard. For all other models one of three available backguards must be ordered separately and installed at the back of the range.
STEP 2: CABINET PREPARATION 1. The range is a free standing unit. If the unit is to be placed adjacent to cabinets, the clearances shown in Fig. 1 are required. The same clearances apply to island installations, except for the overhead cabi nets, which must have a space wide enough to accept the flared island hood, as indicated in Fig.
STEP 2: CABINET PREPARATION FIG. 2a Side View 30" Ranges AY Mln. to Combustibles A 28-3/4' 27-5/8" Optional High Shelf Std. __ Low Back Guard (Provided with 30" Range) 16-1/2".
STEP 2: CABINET PREPARATION GAS AND ELECTRIC SUPPLY ZONES: FIG. 3a Gas & Electrical Supply Zone for PRG304, PRG36 & PRG48 All-Gas Ranges Typical placement shown. Other placement of Gas Supply and Electrical Receptacle within the Electrical and Gas Supply Zone is acceptable.
Installation of Dual Fuel ranges must be planned so that the rough-in of the junction box for the receptacle or conduit connec tion will allow maximum clear ance to the rear of the unit.
STEP 3: UNPACKING, MOVING AND PLACING THE RANGE <► CAUTION: Proper equipment and adequate manpower must be used in moving the range to avoid damage to the unit or the floor. The unit is heavy and rests on adjust able steel legs. • The range has an approximate shipping weight as shown in Chart A.
STEP 3: UNPACKING, MOVING AND PLACING THE RANGE Due to the weight, a dolly with soft wheels should be used to move this unit. The weight must be supported uniformly across the bottom (See Fig.
ALL RANGES CAN TIP INJURY TO PERSONS COULD RESULT INSTALL ANTI-TIP DEVICES PACKED WITH RANGE SEE INSTRALLATION INSTRUCTIONS ■ STEP 4: INSTALLING ANTI-TIP DEVICE For all 30" and 36" ranges, an anti-tip device must be installed as per these instructions.
STEP 4: INSTALLING ANTI-TIP DEVICE Parts Required for Installation of Anti- Tip Device: PRG304 and PRG36 All Gas Ranges (Figures 9 and 10) Thermador Part No. Qty Description 15-10-916 15-10-771 15-10-772 15-10-909 15-10-910 15-10-911 15-10-948 4 1 1 1 1 2 2 Screw.
STEP 4: INSTALLING ANTI-TIP DEVICE PRG304 AND PRG36 All-Gas Ranges (Figures 9, 10, 12a 12b and 13) STEP A: Determine the best location for the PRG Mounting Bracket. The bracket may be mounted to the wall or floor behind the range, offset from either the left or right side wall by 2-3/4" for model PRG304 or 4-5/8" for Model PRG36.
STEP 4: INSTALLING ANTI-TIP DEVICE STEP H: Using the l/4"-20 x 1/2" Hex Head Bolt, Hex Nut and two (2) Flat Washers, securely attach the Adjustable Anti-Tip Channel to the existing hole in the flange located at the bottom rear of the range.
STEP 4: INSTALLING ANTI-TIP DEVICE STEP B: Set the bracket on the floor and turn it until it is oriented properly. The long channel should be on the top with the free end facing towards you, one set of mounting flanges should be resting horizontally on the floor, and the other set of mounting flanges should be positioned vertically facing the rear.
STEP 5: GAS REQUIREMENTS AND HOOKUP Verify the type of gas being used at the installation site. As shipped from the factory, all units are configured for use on natural gas. For use with propane gas, the unit must be converted. Field conversion for use with propane must only be done by qualified service person nel.
STEP 6: ELECTRICAL REQUIREMENTS, CONNECTION & GROUNDING Prior to servicing appliance, always disconnect appliance electrical supply cord, if so equipped, from wall receptacle. If appliance is hard wired to power supply, disconnect power to unit by turning off the proper circuit breaker or disconnecting the proper fuse.
STEP 6: ELECTRICAL REQUIREMENTS, CONNECTION & GROUNDING Dual Fuel models PRDS304, PRDS36 and PRDS48 must be connected to the power supply utilizing one of the following methods.
STEP 6: ELECTRICAL REQUIREMENTS, CONNECTION & GROUNDING A 3 or 4 conductor supply may be connected to the terminal block. A 4 conductor supply shall be used only when the range is installed in a mobile home or where local codes do not permit grounding through the neutral.
STEP 6: ELECTRICAL REQUIREMENTS, CONNECTION & GROUNDING Recommended Grounding Method - All-Gas Models PRG304, PRG36 and PRG48 The 30," 36" and 48" all-gas ranges are factory equipped with a power supply cord with a three-prong grounding plug (with polarized parallel blades).
STEP 6: ELECTRICAL REQUIREMENTS, CONNECTIONS & GROUNDING CASE 2: Electrical Connections and Grounding - with a 4-Conductor Power Supply (to be used only when local codes do not permit grounding through the neutral). Secure the neutral (white) wire of the supply circuit to the neutral terminal of the NEMA 14-50R recep tacle.
STEP 7: BACKGUARD INSTALLATION INSULATION AND RETAINER REMOVAL Before the backguard can be assembled onto Model PRDS304. PRDS36 and PRDS48 Ranges, the insulation retainer and the insulation must be removed to avoid interference. This insulation is not required on the PRDS304, PRDS36 and PRDS48 models.
STEP 8: TEST AND ADJUSTMENT FIG. 23 PROPER FLAME (APPROX.) Griddle. Grill, & Gas Oven Burners 3urner Griddle Grill Gas oven Flame Height Natural Gas 3/4" 1/4" 1-1/2" to 2" •H.
INSTALLER CHECKLIST FINAL CHECK LIST a Placement of unit. □ Specified clearances maintained to cabinet surfaces. LJ Unit Level - front to back - side to side. □ Burner caps positioned properly on sealed burner bases. □ All packaging material removed.
NOTES Page 24.
NOTES Page 25.
THERMADOR® is a leading manufacturer of Convection Micro Thermal Ovens. Convection Thermal Ovens. Thermal Electric Ovens, Warming Drawers. Free-Standing and Slide-In Ranges. Steel Gas ExtraLow5 Cooktops. Steel Gas Cooktops, Glass Gas ExtraLowCooktops, Glass Gas Cooktops.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Thermador PRDS48 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Thermador PRDS48 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Thermador PRDS48, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Thermador PRDS48 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Thermador PRDS48, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Thermador PRDS48.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Thermador PRDS48. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Thermador PRDS48 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.