TPS54810 SL VS420B − MARCH 2002 − R EVISED FEBRUAR Y 2005 4-V TO 6-V INPUT , 8-A OUTPUT SYNCHRONOUS BUCK PWM SWITCHER WITH INTEGRA TED FETS (SWIFT ™ ) 6,4 mm X 9,7 mm FEA TURES D 30-m Ω MOSFET Switches for High Efficiency at 8-A Continuous Output D 0.
TPS54810 SL VS420B − MARCH 2002 − R EVISED FEBRUAR Y 2005 www.ti.com 2 These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam during storage or handling to prevent electrostatic damage to the MOS gates.
TPS54810 SL VS420B − MARCH 2002 − R EVISED FEBRUARY 2005 www.ti.com 3 ELECTRICAL CHARACTERISTICS T J = − 40 ° C to 125 ° C, V I = 4 V to 6 V unless otherwise noted P ARAMETER TEST CONDITIONS MIN TYP MAX UNIT SUPPL Y VOL T AGE, VIN Input voltage range, VIN 4.
TPS54810 SL VS420B − MARCH 2002 − R EVISED FEBRUAR Y 2005 www.ti.com 4 ELECTRICAL CHARACTERISTICS CONTINUED T J = − 40 ° C to 125 ° C, V I = 4 V to 6 V unless otherwise noted P ARAMETER TEST C.
TPS54810 SL VS420B − MARCH 2002 − R EVISED FEBRUAR Y 2005 www.ti.com 5 1 2 3 4 5 6 7 8 9 10 11 12 13 14 28 27 26 25 24 23 22 21 20 19 18 17 16 15 AGND VSENSE COMP PWRGD BOOT PH PH PH PH PH PH PH P.
TPS54810 SL VS420B − MARCH 2002 − R EVISED FEBRUARY 2005 www.ti.com 6 FUNCTIONAL BLOCK DIAGRAM Falling Edge Deglitch Enable Comparator 1.2 V VIN 3.8 V Hysteresis: 0.03 V 2.5 µ s Falling and Rising Edge Deglitch 2.5 µ s VIN UVLO Comparator Hysteresis: 0.
TPS54810 SL VS420B − MARCH 2002 − R EVISED FEBRUARY 2005 www.ti.com 7 TYPICAL CHARACTERISTICS Figure 1 0 10 20 30 40 50 60 − 40 − 15 10 35 60 85 1 10 135 V I = 5 V , I O = 8 A DRAIN-SOURCE ON-.
TPS54810 SL VS420B − MARCH 2002 − R EVISED FEBRUARY 2005 www.ti.com 8 APPLICA TION INFORMA TION Figure 9 shows the schematic diagram for a typical TPS54810 application. The TPS54810 (U1) can provide up to 8 A of output current at a nominal output voltage of 1.
TPS54810 SL VS420B − MARCH 2002 − R EVISED FEBRUARY 2005 www.ti.com 9 PCB LA YOUT Figure 10 shows a generalized PCB layout guide for the TPS54810 Th e VIN pins are connected together on the printed-circuit board (PCB) and bypassed with a low-ESR ceramic-bypass capacitor .
TPS54810 SL VS420B − MARCH 2002 − R EVISED FEBRUARY 2005 www.ti.com 10 AGND BOOT VSENSE COMP PWRGD PH PH PH PH PH PH PH PH PH RT SYNC SS/ENA VBIAS VIN VIN VIN VIN VIN PGND PGND PGND PGND PGND VOUT.
TPS54810 SL VS420B − MARCH 2002 − R EVISED FEBRUARY 2005 www.ti.com 11 LA YOUT CONSIDERA TIONS FOR THERMAL PERFORMANCE For operation at full rated load current, the analog ground plane must provide adequate heat dissipating area.
TPS54810 SL VS420B − MARCH 2002 − R EVISED FEBRUARY 2005 www.ti.com 12 PERFORMANCE GRAPHS (FROM APPLICA TION CIRCUIT SHOWN IN FIGURE 9) Fi g ure 12 I O − Output Current − A Efficiency − % EFFICIENCY vs OUTPUT CURRENT 50 55 60 65 70 75 80 85 90 95 100 0246 8 1 0 V I = 5 V V O = 1.
TPS54810 SL VS420B − MARCH 2002 − R EVISED FEBRUARY 2005 www.ti.com 13 DET AILED DESCRIPTION Under V oltage Lock Out (UVLO) The TPS54810 incorporates an under voltage lockout circuit to keep the device disabled when the input voltage (VIN) is insufficient.
TPS54810 SL VS420B − MARCH 2002 − R EVISED FEBRUARY 2005 www.ti.com 14 particular application needs. T ype 2 or type 3 compensa- tion can be employed using external compensation components. PWM Control Signals from the error amplifier output, oscillator , and current limit circuit are processed by the PWM control logic.
PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Drawing Pins Package Qty Eco Plan (2) Lead/Ball Finish MSL Peak Temp (3) TPS54810PWP ACTIVE HTSSOP PWP 28 50 Green (RoHS & no.
TAPE AND REEL INFORMATION *All dimensions are nominal Device Package Type Package Drawing Pins SPQ Reel Diameter (mm) Reel Width W1 (mm) A0 (mm) B0 (mm) K0 (mm) P1 (mm) W (mm) Pin1 Quadrant TPS54810PWPR HTSSOP PWP 28 2000 330.0 16.4 6.9 10.2 1.8 12.0 16.
*All dimensions are nominal Device Package Type Package Drawing Pins SPQ Length (mm) Width (mm) Height (mm) TPS54810PWPR HTSSOP PWP 28 2000 346.0 346.0 33.
.
.
.
IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Texas Instruments TPS54810 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Texas Instruments TPS54810 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Texas Instruments TPS54810, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Texas Instruments TPS54810 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Texas Instruments TPS54810, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Texas Instruments TPS54810.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Texas Instruments TPS54810. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Texas Instruments TPS54810 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.