User's Guide SLVU392 – July 2010 TPS53125EVM-599 The TPS53125EVM-599 Evaluation Module presents an easy-to-use reference design for a common dual output power supply using the TPS53125 controller in cost-sensitive applications. Also included are the schematic, board layout, and bill of materials.
Description www.ti.com List of Tables 1 TPS53125EVM-599 Electrical and Performance Specifications ...................................................... 2 2 Test Point Description .......................................................................
+ + + + + www.ti.com TPS53125EVM-599 Schematic 3 TPS53125EVM-599 Schematic For Reference Only, See Table x: for Specific Values Figure 1. TPS53125EVM-599 Schematic 3 SLVU392 – July 2010 TPS53125EVM-.
Connector and Test Point Descriptions www.ti.com 4 Connector and Test Point Descriptions 4.1 Enable Jumpers/Switches –SW1 and SW2 The TPS53125EVM-599 board includes independent enable switches for each of the two outputs.
www.ti.com Test Setup 4.2.4 Soft-Start Voltage Monitoring – TP1, TP2, and TP3 TPS53125EVM-599 provides two test points for measuring the soft-start ramp voltages. TP1 monitors the soft-start ramp of Channel 1. TP2 monitors the soft-start ramp of Channel 2.
Test Setup www.ti.com J1 to LOAD1 and J2 to LOAD2 - The connection between J1 and LOAD1 and J2 and LOAD2 of TPS53125EVM-599 can carry as much as 4 Adc each. The minimum recommended wire size is AWG #14, with the total length of wire less than 2 feet (1-foot input, 1-foot return).
LOAD1 1.05V @ 4A F AN V2 + - Oscilloscope 1M W , AC 20mV / div 20MHz LOAD2 1.8V @ 4A V3 - + - + - + A1 - + V VIN V1 + - www.ti.com Test Setup 5.2.2 Test Setup Diagram Figure 2. TPS53125EVM-599 Recommended Test Setup 5.3 Start-Up/Shutdown Procedures Perform the start-up and shutdown procedures in the following manner.
0 1 2 3 4 5 I -LoadCurrent- A LOAD 50 55 60 65 70 75 80 85 90 95 h -Efficiency-% V =8V I V =12V I V =22V I TPS53125EVM-599 Test Data www.ti.com 7. Decrease LOAD2 to 0 A. 5.4 Output Ripple Voltage Measurement Procedure Perform the Output Ripple Voltage Measurement procedure in the following manner.
0 10 20 30 40 50 60 70 80 90 100 h -Efficiency-% 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 I -LoadCurrent- A LOAD V =8V I V =12V I V =22V I V =8V I V =12V I V =22V I 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 I -LoadCurrent- A LOAD 1.
1.82 1.825 1.83 1.835 1.84 1.845 1.85 1.855 1.86 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 I -LoadCurrent- A LOAD V -OutputV oltage-V O V =8V I V =12V I V =22V I TPS53125EVM-599 Test Data www.ti.com V IN = 8 V – 22 V, V OUT1 = 1.
www.ti.com TPS53125EVM-599 Test Data V IN = 12, V OUT2 = 1.80, I OUT2 = 4 A Figure 8. TPS53125EVM-599 Output Voltage Ripple 6.4 Switch Node tV IN = 12, V OUT1 = 1.
TPS53125EVM-599 Assembly Drawings and Layout www.ti.com V IN = 12, V OUT2 = 1.80, I OUT2 = 4A Ch1: TP11 (SW2) Figure 10. TPS53125EVM-599 Switching Waveforms 7 TPS53125EVM-599 Assembly Drawings and Layout The following figures ( Figure 11 through Figure 15 ) show the design of the TPS53125EVM-599 printed-circuit board.
www.ti.com TPS53125EVM-599 Assembly Drawings and Layout Figure 12. TPS53125EVM-599 Top Copper, Viewed From Top Figure 13. TPS53125EVM-599 Bottom Copper, Viewed From Bottom 13 SLVU392 – July 2010 TPS.
TPS53125EVM-599 Assembly Drawings and Layout www.ti.com Figure 14. TPS53125EVM-599 Internal 1, X-Ray View From Top Figure 15. TPS53125EVM-599 Internal 2, X-Ray View From Top 14 TPS53125EVM-599 SLVU392.
www.ti.com TPS53125EVM-599 Bill of Materials 8 TPS53125EVM-599 Bill of Materials The Table 3 contains the bill of materials for TPS53125EVM-599. The reference designators reference the schematic in Figure 1 and assembly locations in Figure 11 . The components listed with a quantity of 0 are not populated on the PCB but are provided for reference.
Evaluation Board/Kit Important Notice Texas Instruments (TI) provides the enclosed product(s) under the following conditions: This evaluation board/kit is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION, OR EVALUATION PURPOSES ONLY and is not considered by TI to be a finished end-product fit for general consumer use.
IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Texas Instruments TPS53125EVM-599 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Texas Instruments TPS53125EVM-599 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Texas Instruments TPS53125EVM-599, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Texas Instruments TPS53125EVM-599 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Texas Instruments TPS53125EVM-599, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Texas Instruments TPS53125EVM-599.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Texas Instruments TPS53125EVM-599. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Texas Instruments TPS53125EVM-599 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.