1.0 Quick Refer ence Guide 3 © Baxi Heating UK Ltd 2012 Reset bar 0 1 2 3 4 1 2 3 4 5 PM 7 8 9 10 11 12 1 2 3 4 5 AM 7 8 9 10 11 12 0 Reset bar 0 1 2 3 4 ON/OFF/Reset Selector Switch Display Central Heating Temperature Control Domestic Hot Water Temperature Control System Pressure Gauge OFF Position The boiler will not operate.
2.0 T r oubleshooting 4 © Baxi Heating UK Ltd 2012 ST AR T Make sure the gas supply is turned ON and check if other gas appliances are operating (e.g.
2.0 T r oubleshooting 5 © Baxi Heating UK Ltd 2012 Is the Integral Timer ON and calling for heat ? Ensure timer is set for Central Heating ON (see Section 7.
3.0 Repressurising the System 6 © Baxi Heating UK Ltd 2012 bar 0 1 2 3 4 bar 0 1 2 3 4 Fig. 1 Fig. 2 Normal Pressure Requires Repressurising 3.1 Central Heating System Pressure 1. The water pressure in the central heating system is indicated by the pressure gauge.
4.0 Clearances 7 © Baxi Heating UK Ltd 2012 Fig. 4 150mm Min* 780mm 450mm 200mm Min (300mm Min if using 80/125mm flueing system) 5mm Min 5mm Min 450mm Min For Servicing Purposes In Operation 5mm Min 4.1 For your Safety 1. This appliance must have been installed in accordance with the manufacturer’s instructions and the regulations in force.
5.0 Care of the Boiler 8 © Baxi Heating UK Ltd 2012 5.1 Cleaning the Outer case The painted panels should be wiped with a damp cloth and then dried completely. DO NOT USE ABRASIVE CLEANING AGENTS. 5.2 Protection & Precaution 1. The boiler incorporates an integral frost protection feature that will operate in both modes.
6.0 Legislation 9 © Baxi Heating UK Ltd 2012 6.1 Installation, Commissioning, Service & Repair 1. This appliance must be install in accordance with the manufacturer’s instructions and the regulations in force. Read the instructions fully before installing or using the appliance.
1 2 3 4 5 PM 7 8 9 10 11 12 1 2 3 4 5 AM 7 8 9 10 11 12 0 7.0 Setting the Timer 10 © Baxi Heating UK Ltd 2012 7.1 Setting the Timer The Electro-Mechanical Timer allows the central heating system to be set every 15 minutes. Using the three position switch the timer will allow either constant operation, timed operation or central heating off.
8.0 Emergency 11 © Baxi Heating UK Ltd 2012 Gas Tap Heating Flow, Heating Return and Mains Water Inlet Isolating Valves Fig. 8 In an Emergency If a water or gas leak occurs or is suspected, the boiler can be isolated at the inlet valves as follows; 1.
9.0 W arranty & Service © Baxi Heating UK Ltd 2012 7202086-05 (5/12) Information Label All descriptions and illustrations provided in this leaflet have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Baxi Potterton G.C.No 47 393 18 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Baxi Potterton G.C.No 47 393 18 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Baxi Potterton G.C.No 47 393 18, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Baxi Potterton G.C.No 47 393 18 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Baxi Potterton G.C.No 47 393 18, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Baxi Potterton G.C.No 47 393 18.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Baxi Potterton G.C.No 47 393 18. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Baxi Potterton G.C.No 47 393 18 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.