P/N 99101100 2 REV. F 5-1-01 SECTION I. PUMP SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: 1 .
REV. F 5-1-01 3 P/N 99101100 SECTION III. CHECK VALVE INSTALLATION INSTRUCTIONS A . INSTALLATION 1 . Turn the pump off, shut off any automatic controls to assure that the system is not inadvertently started during servicing. 2 . Open the High Flow™ manual air relief valve.
P/N 99101100 4 REV. F 5-1-01 6 . Insert the Check Valve into the outlet port approximately 3/4" to 1" deep making sure the rubber diaphragm facing outward (towards you), see Diagram 1. 7 . Reconnect the return hose to the outlet port and tighten the union fitting.
REV. F 5-1-01 5 P/N 99101100 5 . Do not mount electrical controls (on/off switches, timer, etc.) over the filter. You need to be able to stand clear of the filter when starting the pump. 6 . Attach the hair and lint pot to the front of the pump. This is an O-ring seal fitting that requires hand tightening only.
P/N 99101100 6 REV. F 5-1-01 SECTION V. INITIAL START-UP AND RESTART INSTRUCTIONS. 1 . Be sure all connections have been made and are secure. 2 . Make sure the hair and lint pot of the pump is filled with water. (FAILURE TO FILL THE HAIR AND LINT POT WITH WATER WILL RESULT IN DAMAGE TO THE PUMP AND PUMP SEAL).
REV. F 5-1-01 7 P/N 99101100 8 . Remove the CARTRIDGE ELEMENT assembly from the filter body by using the lifting handles and pulling straight up. 9 . Remove the CARTRIDGE ELEMENT from the core assembl.
P/N 99101100 8 REV. F 5-1-01 SECTION VII. WINTERIZING THE FILTER 1 . In areas that have freezing winter temperatures, the pool equipment must be winterized to protect it from damage. 2 . With the pump turned off, open the High Flow™ manual air relief valve.
REV. F 5-1-01 9 P/N 99101100 SECTION IX. TROUBLE SHOOTING Problem Cause Remedy Pool water not 1. Pool chemistry not adequate to inhibit algae growth. Maintain pool chemistry or consult pool service technician . sufficiently clean. 2. Inadequate turnover rate.
P/N 99101100 10 REV. F 5-1-01 3 . SHAFT SEAL - (rotary seal). The shaft seal consists of two parts: a. Rotating ceramic seal, press fitted into the impeller. b. A stationary spring loaded seal, press fitted into the rear of the volute. 4 . THE ELECTRIC MOTOR.
REV. F 5-1-01 11 P/N 99101100 Replacement Parts Find Part Description No. No. 1 98209800 High Flow Manual Air Relief Valve 2 53003201 Pressure Gauge 3 178553 Lid, 50/100 Sq./Ft. 3 178561 Lid, 75 Sq./Ft. 4 59052900 Locking Ring Assy. 5 87300400 Body O-ring 6 59016200 Air Bleed Sock Kit 7 59053500 Center Core, 50 Sq.
P/N 99101100 12 REV. F 5-1-01 SECTION XI. TECHNICAL DATA (continued) B. MAXIM PUMP Find Part Description No. No. 1 98206400 Plug, ¼ in. with O-ring 2 57006500 O-ring 3 39102503 Volute, S Series, vert.
REV. F 5-1-01 13 P/N 99101100 SECTION XI. TECHNICAL DATA, (continued) C. DYNAMO PUMP D Y N A M O C OO SNAP TAB SNAP TAB MOTOR - SEE NOTE 1 SNAP TAB SLOT 18 26 25 24, 24A 20 21 27 19 23 22 12 17 13 14 15 11 10 16 9 9 7 8 6 5 4 3 2 1 * * * Motors 1 35-6471 ¾ A std.
P/N 99101100 14 REV. F 5-1-01 15-5118 2 5 ft. cord and plug 15-5370 2 5 ft. cord and plug, CSA approved 15-5234 3 ft. cord with twist lock plug 35-2245 Strain relief bushing for cords 15-5297 P hoto sensor add-on 2 3 35-4650 B ody - motor enclosure 2 4 35-4656 C a p - motor enclosure 2 5 15-4716 S crew - #10 self-tapping 2 6 15-5371 C ord - 25 ft.
REV. F 5-1-01 15 P/N 99101100.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté System Works 99101100 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du System Works 99101100 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation System Works 99101100, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le System Works 99101100 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le System Works 99101100, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du System Works 99101100.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le System Works 99101100. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei System Works 99101100 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.