NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 1 Unvented Decorative Gas Fireplaces P/N 904538 REV. E 02/2004 CF5500-CMN CF6500-CMN CF5500-CMP CF6500-CMP MODELS ST ANDARD SERIES INST ALLA TION INSTRUCTIONS FOR USE ONLY WITH DECORATIVE TYPE UNVENTED ROOM HEATERS.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 2 Check the inventory list to be sure that you have all the necessary parts in usable condition. Also check for concealed damage. IMPORTANT SAFETY INFORMATION INSTALLER: PLEASE LEAVE THESE INSTRUC- TIONS WITH THE OWNER.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 3 The National Fuel Gas Code defines a con- fined space as a space whose volume is less than 50 ft 3 per 1,000 BTU/Hr (4.8 m 3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 ft 3 per 1,000 BTU/Hr (4.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 4 3. Add the BTU/hr of all the fuel burning appli- ances in the space. Vent-Free heater (Max.) ______ BTU/hr Gas appliance #1* ______ BTU/hr Gas applian.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 5 WARNING: DO NOT INSTALL THESE APPLIANCES: • WHERE CURTAINS, FURNITURE, CLOTHING OR OTHER FLAMMABLE OBJECTS ARE LESS THAN 42" FROM THE FRONT OF THE UNVENTED ROOM HEATER. • IN HIGH TRAFFIC AREAS.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 6 Note: Framing dimensions in Figures 4 - 9 are calculated for a nailing flange depth of ¹⁄₂ " (13 mm). Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Step 3 . Remove the nailing flanges from the lower control compartment and install in place with three (3) screws each.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 7 The gas control valve is located in the lower control compartment. To access the valve open the lower control compartment door ( Figure 13 ). The control valve has a ³⁄₈ " NPT thread inlet port and is fitted with a 3" (76 mm) long nipple, ³⁄₈ " NPT on both ends.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 8 Figure 16 Note: Supply wires may be alternatively connected to the outlet using the screw terminals, however the black supply wire must be ganged wired to the same terminal that the pre-wired black wire is attached to and the white supply wire must be connected to the opposite side of the outlet.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 9 Figure 18 Step 10. Checking the System – After the gas line is installed, logs are in place and the system is leak checked, run initial system checkout before closing up the front of the unit. Follow the pilot lighting instructions on pages 16 and 17.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 10 Rear Burner Flames – The rear flames rising in front of center and rear logs should be yellow and extend about 2 ¹⁄₂ – 3" above the large logs for natural gas and 1 ¹⁄₂ – 2 ¹⁄₂ ” above for propane gas.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 11 The appliances covered in this manual are heater rated and produce a great deal of heat. Decorative brass trim pieces and hoods may tarnish because of their proximity to the heater opening and front face.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 12 8. CAUTION: DO NOT OPERATE THIS APPLI- ANCE WITH A BROKEN GLASS PANEL. Where broken glass exists, the complete glass enclo- sure panel must be replaced. See the Replace- ment Parts List on page 18 for correct replace- ment part numbers.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 13 Cleaning and Servicing WARNING: TURN OFF THE APPLIANCE AND ALLOW TO COOL BEFORE CLEAN- ING. WARNING: ALWAYS TURN OFF THE GAS SUPPLY TO THE PILOT BEFORE CLEAN- ING. BEFORE RE-LIGHTING, REFER TO THE LIGHTING INSTRUCTIONS IN THIS MANUAL.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 14 ACCESSORIES AND COMPONENTS Forced Air Kit FAB-1100 Remote Control Kit RCK Rocker Switch Kit RS VF5-BRLK Brass Louver Kits VF6-BRLK 1-Piece Decorative.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 15 CF5500 SPECIFICATIONS Figure 28 CF6500 SPECIFICATIONS Figure 29 37" (940 mm) 36" (914 mm) 30" (762 mm) 31 ¹⁄₂ " (800 mm) 15&.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 16 TROUBLESHOOTING THE CF MILLIVOL T GAS CONTROL SYSTEM 1. Spark ignitor will not light pilot after repeated triggering of black button. 2. Pilot will not stay lit after carefully following the lighting instructions.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 17 LIGHTING INSTRUCTIONS – MILLIVOLT WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. FOR YOUR SAFETY READ BEFORE LIGHTING • Do not use any phone in your building.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 18 REPLACEMENT PARTS LIST — MILLIVOLT GAS CONTROLS — MILLIVOLT CF5500-CMN CF5500-CMP CF6500-CMN CF6500-CMP CF5500-CMN CF5500-CMP CF6500-CMN CF6500-CMP No. DESCRIPTION Part No. Qty. Part No. Qty. Part No.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 19 REPLACEMENT PARTS 12 5 2 4 2 1 6 7 21 3 20 13 7 22 24 23 8 11 10 9 b. a. c. d. (SIT Valve Shown).
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 20 Printed in U.S.A. © 1999 by SFC P/N 904538 REV. E 02/2004 Catalytic Gas Fireplace Manufacturer's Limited Warranty 10 Y ears THE WARRANTY The manufacturer warrants the components of this Catalytic Gas Fireplace manufactured by SFC, INC.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Superior CF5500-CMP c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Superior CF5500-CMP - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Superior CF5500-CMP, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Superior CF5500-CMP va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Superior CF5500-CMP, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Superior CF5500-CMP.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Superior CF5500-CMP. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Superior CF5500-CMP ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.