Manuel d'utilisation / d'entretien du produit RGX3600 du fabricant Subaru Robin Power Products
Aller à la page of 31
3ZZ9990184 (英 ・露・亜 ) ISSUE EMD-GU2149 August 2005 CE-SK PRINTED IN JAPAN.
ENGLISH FOREWORD Thank you for purchasing a Robin generator . This manual covers operation and maintenance of the Robin generators. All information in this publication is based on the latest production information available at the time of approval for printing.
CONTENTS 1. SAFETY PRECAUTIONS ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ 1 2. SPECIFICA TIONS ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ 3 3.
ENGLISH 1. SAFETY PRECAUTIONS − 1 − Please make sure you review each precaution carefully. Do not operate the generator near gasoline or gaseous fuel because of the potential danger of explosion or fire. Do not fill the fuel tank with fuel while the engine is running.
− 2 − Do not contact the generator to a commercial power line. Connection to a commercial power line may short circuit the generator and ruin it or cause electric shock hazard. Use the transfer switch for connecting to domestic circuit. WARNING Engine becomes extremely hot during and for some time after operation.
ENGLISH 2. SPECIFICA TIONS − 3 − MODEL T ype Starting system L mm mm mm mL L kg Model T ype V oltage regulating system kV A (kW) Rated output AC Output kV A (kW) Maximum output Rated voltage Fuel tank capacity H Engine oil capacity Spark plug Dry weight Specifications are subject to change without notice.
3. COMPONENTS − 4 − Fuel tank Fuel gauge Engine switch Choke lever Oil drain plug Oil gauge (oil filler) Spark plug cap Air cleaner Exhaust outlet Tank cap Fuel strainer ( Fuel cock ) Muffler cover Recoil starter Recoil starter handle Control panel RGX48000(GEN)_GU2122 05.
Full power switch Voltmeter DC circuit breaker DC output terminal AC circuit breaker Earth ( ground ) terminal Earth ( ground ) terminal Earth ( ground ) terminal Earth ( ground ) terminal Earth ( gro.
− 6 − Voltmeter DC circuit breaker DC output terminal AC circuit breaker Earth ( ground ) terminal Earth ( ground ) terminal Earth ( ground ) terminal AC receptacle (50Hz-230V) (50Hz-230V) (50Hz-2.
4. PRE-OPERA TION CHECKS − 7 − ENGLISH Upper level Oil filler cap (Oil gauge) Lower level CHECK ENGINE OIL Before checking or refilling oil, be sure generator is located on stable and level surface with engine stopped. ■ Remove oil filler cap and check the engine oil level.
− 8 − ■ Check fuel level at fuel level gauge. ■ If fuel level is low , refill with unleaded automotive gasoline. ■ Be sure to use the fuel filter screen on the fuel filter neck. LEVEL Fuel filter screen Fuel tank cap Do not refuel while smoking or near open flame or other such potential fire hazards.
− 9 − ENGLISH CHECKING COMPONENT P ARTS Check following items before starting engine: ■ Fuel leakage from fuel hose, etc. ■ Bolts and nuts for looseness. ■ Components for damage or breakage. ■ Generator not resting on or against any adjacent wiring.
5. OPERA TING PROCEDURES − 10 − (a) T urn the Engine switch to the position "ON". (b) T urn the AC circuit breaker to the position "OFF".
ENGLISH − 11 − Pull rapidly (e) Pull the starter handle slowly until resistance is felt. This is the "compression" point. Return the handle to its original position and then pull swiftly . ■ If the engine fails to start after several attempts, repeat above procedures with choke lever returned to "OPEN" position.
− 12 − A Single voltage type (a) Check the voltmeter for proper voltage. ■ This generator is thoroughly tested and adjusted in the factory . If the generator does not produce the specified voltage, consult your nearest Robin dealer or service shop.
ENGLISH − 13 − Up to 30 amperes Up to 16 amperes Up to total 15 ampere from two receptacles Up to 15 amperes TABLE 1 NOTE : When the AC circuit breaker turns off during operation, the generator is over loaded or the appliance is defective.
− 14 − B Dual voltage type (RGX4800) Switch position Lower V oltage Receptacle Higher V oltage Receptacle 120V Activated full rated output N.A 120/240V Activated half of rated output Activated full rated output FULL POWER SWITCH (a) Select the voltage using the FULL POWER SWITCH in accordance with the electrical appliance.
ENGLISH − 15 − (2) DC APPLICA TION The DC terminal is used only for charging 12 volt batteries. It provides up to 12V -8.3A (100W) of maximum power . CONNECTION OF CABLE : ■ Connect positive (red) terminal on generator to positive (+) terminal on battery .
− 16 − STOPPING THE GENERA T OR (a) T urn off the power switch of the electric equipment and unplug the cord from receptacle of the generator . (b) T urn the AC circuit breaker to the "OFF" position. (c) Allow the engine about 3 minutes to cool down at no-load before stopping.
ENGLISH 6. W A TT AGE INFORMA TION − 17 − Some appliances need a "surge" of energy when starting. This means that the amount of electrical power needed to start the appliance may exceed the amount needed to maintain its use.
− 18 − VOL T AGE DROP IN ELECTRIC EXTENSION CORDS When a long electric extension cord is used to connect an appliance or tool to the generator , a certain amount of voltage drop or loss occurs in the extension cord which reduces the effective voltage available for the appliance or tool.
ENGLISH 7. MAINTENANCE SCHEDULE − 19 − DAIL Y ■ Check oil level. ■ Check all components according to "PRE- OPERA TION CHECKS." EVER Y 50 HOURS ■ W ash cleaner element. -more often if used in dirty or dusty environments. ■ Check spark plug, clean if necessary .
8. "HOW -TO" MAINTENANCE − 20 − ENGINE OIL CHANGE ■ Change engine oil every 100 hours. (For new engine, change oil after 20 hours.) (a) Drain oil by removing the drain plug and the oil filler cap while the engine is warm.
ENGLISH − 21 − CLEANING AND ADJUSTING SP ARK PLUG (a) If the plug is contaminated with carbon, remove it using a plug cleaner or wire brush. (b) Adjust the electrode gap to 0.6 to 0.7 mm (0.024 to 0.028 in.). Gap 0.6 to 0.7 mm ( 0.024 to 0.028 in.
9. PREP ARA TION FOR ST ORAGE − 22 − The following procedures should be followed prior to storage of your generator for periods of 6 months or longer . ■ Drain fuel from fuel tank carefully by disconnecting the fuel line. Gasoline left in the fuel tank will eventually deteriorate making engine- starting difficult.
10. TROUBLESHOOTING − 23 − ENGLISH When generator engine fails to start after several attempts, or if no electricity is available at the output socket, check the following chart. If your generator still fails to start or generate electricity , contact your nearest Robin dealer or service shop for further information or corrective procedures.
11 . WIRING DIAGRAM − 24 − Y Y Grn/Y W R R Blu Blk Blk Blk Blk Spark plug Condenser Winding AC Winding 2 AC Winding 1 AC output receptacle Voltmeter Ignition coil Oil sensor control unit REC1 REC1 V IG O.
− 25 − ENGLISH Y Y Grn/Y W R R Blu Blk Blk Blk Blk Spark plug Condenser Winding AC Winding 2 AC Winding 1 AC output receptacle Voltmeter Ignition coil Oil sensor control unit REC1 REC1 V IG O.
− 26 − RGX4800 (50Hz-220V , 240V) RGX4800 (60Hz-120/240V) Y Y Grn/Y W R Blu Blk Blk Blk Spark plug Condenser Winding AC Winding 2 AC Winding 1 AC output receptacle AC output receptacle Voltmeter Ignition coil Oil sensor control unit REC1 REC4 REC1 V IG O.
− 27 − ENGLISH Y Y Grn/Y W R R Blu Blk Blk Blk Blk Spark plug Condenser Winding AC Winding 2 AC Winding 1 AC output receptacle Voltmeter Ignition coil Oil sensor control unit V IG O.
3ZZ9990184 (英 ・露・亜 ) ISSUE EMD-GU2149 August 2005 CE-SK PRINTED IN JAPAN.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Subaru Robin Power Products RGX3600 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Subaru Robin Power Products RGX3600 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Subaru Robin Power Products RGX3600, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Subaru Robin Power Products RGX3600 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Subaru Robin Power Products RGX3600, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Subaru Robin Power Products RGX3600.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Subaru Robin Power Products RGX3600. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Subaru Robin Power Products RGX3600 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.