Manuel d'utilisation / d'entretien du produit C3548 COMPACT du fabricant Studer Innotec
Aller à la page of 23
STUDER INNOTEC COMPACT COMPACT COMPACT COMPACT User manual COMPACT V2. 0 E User and installer Manual Sinewa v e Inverter, Batt ery charger COMPACT C1312 COMPACT C1312 COMPACT C1312 COMPACT C1312 COMPA.
STUDER INNOTEC COMPACT COMPACT COMPACT COMPACT User manual COMPACT V2.0 E 2 Index table 1 GENERAL INFORMATION .......................................................................................................... .......................... 4 1.1 O PERA TI NG I NST RUCTI ONS .
STUDER INNOTEC COMPACT COMPACT COMPACT COMPACT User manual COMPACT V2.0 E 3 4.7.3 Delayed mode of the Trans fer System...................................................................................... ................... 17 4.8 T HE S OL AR C HAR GE R EGU LAT OR ( OPTION ) .
STUDER INNOTEC COMPACT COMPACT COMPACT COMPACT User manual COMPACT V2.0 E 4 1 General Information 1.1 Operating instruction s This manual is a part of the delivery package of every COMPACT inverter-charger. It serves as guidelines for safe and efficient operation of COMPACT.
STUDER INNOTEC COMPACT COMPACT COMPACT COMPACT User manual COMPACT V2.0 E 5 During operation of COMPACT, high tensions are generated at the connections and inside of the appliance which could be deadly fat al. W ork on the appliance and on the installation should only be carried out by qualified and trained personnel.
STUDER INNOTEC COMPACT COMPACT COMPACT COMPACT User manual COMPACT V2.0 E 6 2 Introduction The COMPACT is a sine wave in verter with integrated batt ery charger and solar charger regulator with many a.
STUDER INNOTEC COMPACT COMPACT COMPACT COMPACT User manual COMPACT V2.0 E 7 2.2.4 The solar charge regu lator (optional) W ith the built-in solar charge regulator, the COMPACT is a complet e solar-power-center. In a solar installation this r egulator ensures that the batteri es are charged correctly.
STUDER INNOTEC COMPACT COMPACT COMPACT COMPACT User manual COMPACT V2.0 E 8 2.3.3 Parallel- Series Connection: 3 A ssembl y 3.1 Place of as sembly The location of the COMPACT must be chosen b y the following criteria: Protection from unauthorized handling.
STUDER INNOTEC COMPACT COMPACT COMPACT COMPACT User manual COMPACT V2.0 E 9 3.3.2 Protection cover for the terminals connections The protection is available in option (Or der re f. CFC-01) and avoid to do wrong hazardous connection on the terminals 230Vac.
STUDER INNOTEC COMPACT COMPACT COMPACT COMPACT User manual COMPACT V2.0 E 10 K AC Output Connecting terminal for AC-output L Caution… Caution: Check Polarity(+/-) before connecting the battery! Polarity reversal can damage the COMPACT.
STUDER INNOTEC COMPACT COMPACT COMPACT COMPACT User manual COMPACT V2.0 E 11 3.5.5 Connect the Solarmodules: SOLA R +/- (Only f or solar op tion) Solar modules are connect ed on these terminals. Under no cir cumstances should any other energ y source i.
STUDER INNOTEC COMPACT COMPACT COMPACT COMPACT User manual COMPACT V2.0 E 12 OFF AC O UT AC I N Ove r T emp Overl oad ON/OFF SOLAR CHARGE Batt Low /High Contact manual AUX.
STUDER INNOTEC COMPACT COMPACT COMPACT COMPACT User manual COMPACT V2.0 E 13 4.2 Light Emitting Diodes: LED Marking LED lit LED blinks 1 AC IN Voltage corresponding to self - adjusted values is at the AC IN input. Voltage, outside of the self- adjusted values is at the AC IN input.
STUDER INNOTEC COMPACT COMPACT COMPACT COMPACT User manual COMPACT V2.0 E 14 4.5 The Inverter An Inverter is built in t he COM PACT, which generat es a sinusoidal alternating voltage of a very high q uality. W ith this Inverter any alt ernating voltag e consuming device 230Vac up to the nom inal power of your COMPACT can be operated.
STUDER INNOTEC COMPACT COMPACT COMPACT COMPACT User manual COMPACT V2.0 E 15 1.9 2.3 2.50 [V/cell] 2.1 A B C D 20 60 40 70 [A] A B C D t Equalization Absorption Float ing Charging current (adjusted) Charging time Egalization time Absorption time Floa ting 4.
STUDER INNOTEC COMPACT COMPACT COMPACT COMPACT User manual COMPACT V2.0 E 16 the OUTPUT less it’s give to the charger. Priority f or the OUTPUT. W hen the power sharing is used the LED 200% (red) is lit to point out that’s the char ge is limited.
STUDER INNOTEC COMPACT COMPACT COMPACT COMPACT User manual COMPACT V2.0 E 17 Note: In the I nverter operation, The COMPACT generates a true sinusoidal and quartz stabilized output voltage.
STUDER INNOTEC COMPACT COMPACT COMPACT COMPACT User manual COMPACT V2.0 E 18 Maximum Contact load: -230Vac /16 A mp-30Vdc/1 A ! W ith t he Push Button 21 „AUXILARY CONTACT“ the contact can be manually switched on or off independent of programming and the operating situation.
STUDER INNOTEC COMPACT COMPACT COMPACT COMPACT User manual COMPACT V2.0 E 19 4.11 The Temperat ure sensor Operating voltage of lead-acid batter ies change depending on the temperature. To correct the operating voltages according to t he actual temperatures, a temperature sensor can be connected to th e C OM PAC T.
STUDER INNOTEC COMPACT COMPACT COMPACT COMPACT User manual COMPACT V2.0 E 20 5.3.2 Set the voltage and ti ming threshold The programming is done in accordance with the following steps: Push and hold down, the Push Button 21 (Program) and the Push Button 19 (Change status) for minimum 2 seconds simultaneously.
STUDER INNOTEC COMPACT COMPACT COMPACT COMPACT User manual COMPACT V2.0 E 21 5.4.3 Example 5.4.3.1 Auxiliary Contact as generator starter W he n in the programming of the Auxiliary Contact, the Batt ery Capacity (LED 15-18) is used as a condition, then you must take note of the following r equirements.
STUDER INNOTEC COMPACT COMPACT COMPACT COMPACT User manual COMPACT V2.0 E 22 5.5.1 Diagram of the different mode 9 Show an off LED Show a blinking LED Show a lighted LED CHARGER INVERTER AC OUT AC IN 1 2 7 8 9 All the f unctions are enabled. This is the factory set ting.
STUDER INNOTEC COMPACT COMPACT COMPACT COMPACT User manual COMPACT V2.0 E 23 8 Technical Data Ty pe C131 2 C131 2 C131 2 C131 2 C232 4 C232 4 C232 4 C232 4 C354 8 C354 8 C354 8 C354 8 Inve rter Nominal b attery voltage 12V 24V 48V Input voltage range 9.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Studer Innotec C3548 COMPACT c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Studer Innotec C3548 COMPACT - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Studer Innotec C3548 COMPACT, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Studer Innotec C3548 COMPACT va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Studer Innotec C3548 COMPACT, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Studer Innotec C3548 COMPACT.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Studer Innotec C3548 COMPACT. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Studer Innotec C3548 COMPACT ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.