VIDEO PROJECTOR VPL-VW85 PROTOCOL MANUAL 1st Edition.
VPL-VW85 ! W ARNING This manual is intended f or qualified ser vice personnel only . T o reduce the risk of electr ic shock, fire or injury , do not perf or m any ser vicing other than that contained in the operating instructions unless you are qualified to do so.
1 (T) VPL-VW85 Table of Contents 1. Overview 1-1. Introduction ........................................................................ 1 1-2. Glossary of Terms .............................................................. 1 1-3. Protocol Stack Structure .
.
1 VPL-VW85 1. Overview 1-1. Introduction The projector is remotely controllable over RS-232C. It is useful for setting up the projector away from the operator. This protocol manual describes the specifications such as packet format and procedures for controlling the projector.
2 VPL-VW85 2. Common Commands 2-1. Sub Commands Sub Command is the value which is used by Simplified Command. Value is assigned for executing function. For example, if you want to change the picture mode, the appropriate value assigned for the desired picture mode should be chosen.
3 VPL-VW85 <Table 1> <Table 2> Remarks Item Number Data Item Upper byte Lower byte Data Byte Advanced Iris 00h 1Dh Off 0000h Set/Get Manual 0001h Auto1 0002h Auto2 0003h Real Color Process.
4 VPL-VW85 <Table 1> <Table 2> Remarks Item Number Data Item Upper byte Lower byte Data Byte User Gain Red 00h 50h Set Value FFE2h to 001Eh ( _ 30 to 30) Set/Get User Gain Green 00h 51h Se.
5 VPL-VW85 Table 2-3 ITEM List For Setup <Table 1> <Table 2> Remarks Item Number Data Item Upper byte Lower byte Data Byte Input 00h 01h Video 0000h Set/Get S Video 0001h Input A 0002h Com.
6 VPL-VW85 Table 2-5 ITEM List For Infrared Remote Command <Table 1> <Table 2> Remarks Item Number Data Item Upper byte Lower byte Data Upper byte Lower byte Infrared Remote 17h Refer to the 00h 00h Set Only Command section 2-1-2 * 1 .
7 VPL-VW85 2-1-2. Infrared Remote Command Code Tables are shown per function category. . 15 bit PROJECTOR: Table 2-6-Table 2-9 . 20 bit PROJECTOR-E: Table 2-6-Table 2-9 .
8 VPL-VW85 Table 2-7 Infrared Remote Command Code For Screen CATEGORY Code Name 15 bit 20 bit PROJECTOR PROJECTOR-E O_ 47 PITCH O_ 48 SHIFT _O 60 APA _O 61 PHASE _O 62 LENS ZOOM _O 63 LENS SHIFT _O 64.
9 VPL-VW85 Table 2-9 Infrared Remote Command Code For Installation CATEGORY Code Name 15 bit 20 bit PROJECTOR PROJECTOR-E _O 00 V KEYSTONE + _O 01 V KEYSTONE _ _O 02 LENS SHIFT ← _O 03 LENS SHIFT .
10 VPL-VW85 2-2. Reply <Table 3> Item Number Data Item Data Upper byte Lower byte ACK Complete 00h 00h NAK Undefined Command 01h 01h Size Error 04h Select Error 05h Range Over 06h Not Applicable.
11 VPL-VW85 3. RS-232C 3-1. Connection Communication is enabled by the use of a D-Sub 9 Pin cross (reverse) cable. The pin assignment of D-Sub 9 Pin and D-Sub 25 Pin is as follows. Pin numbers indicated as D-Sub 25 Pin are not used. Assured cable length: 15 m (However, assurance may not be applicable for some cables.
12 VPL-VW85 3-3. Communication Procedure 3-3-1. Outline of Communication All communication between CONTROLLER (PC, etc.) and DEVICE (PROJECTOR) is performed by the command block format. Communication is started by the issue of a command at CONTROLLER and ended when the return data is sent to CONTROLLER after DEVICE receives the command.
13 VPL-VW85 3-6. Command Block Format The block format of Simplified Command for RS-232C as shown in the Fig. 1-1. In this section, the block format for Simplified Command is provided. 3-6-1. Simplified Command [Send] The block format for sending request is shown below.
14 VPL-VW85 3-7. Packet Examples 3-7-1. Change “Wide Mode” to “Zoom” START CODE = A9h ITEM NUMBER = 0020h (Wide Mode) SET/GET = 00h (SET) DATA = 0003h (Zoom) CHECK SUM = 23h END CODE = 9Ah You will receive the packet below if the process is successfully completed.
VPL-VW85 The material contained in this manual consists of inf or mation that is the proper ty of Sony Cor poration. Sony Corporation e xpressly prohibits the duplication of any portion of this manual.
Printed in Japan Son y Cor poration 2009. 9 16 ©2009 VPL-VW85 (CN) VPL-VW85 (J) VPL-VW85 (SY) VPL-VW85 (U) E 9-968-691-01.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Sony VPL-VW85 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Sony VPL-VW85 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Sony VPL-VW85, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Sony VPL-VW85 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Sony VPL-VW85, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Sony VPL-VW85.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Sony VPL-VW85. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Sony VPL-VW85 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.