Manuel d'utilisation / d'entretien du produit DA5320 du fabricant Sigma
Aller à la page of 21
Document No. 14811 January 2005 DA5320 8-CHANNEL AES AUDIO MIXER/ ROUTER MODULE.
14811 • January 2005 • Front Matter Page ii.
14811 • January 2005 • Front Matter Page iii SIGMA ELECTRONICS's products are certified to comply with the regulations and recommendations of several certifying agencies. For complete details, as well as copies of the certification documents, please visit our website at www.
14811 • January 2005 • Front Matter Page iv CUSTOMER APPRECIATION STATEMENT SIGMA ELECTRONICS would like to take this opportunity to compliment you on your intelligent selection of high-quality audio or video equipment. It is our goal to provide the highest quality products and unparalleled service to all of our valued customers.
14811 • January 2005 • Introduction/overview Page 1 INTRODUCTION/OVERVIEW The multi-function Sigma DA5320 8 Channel Mixer/Router module is a member of the Sigma 5000 series OctaStream ™ product line.
14811 • January 2005 • Receiving Inspection and Unpacking Page 2 RECEIVING INSPECTION AND UNPACKING By the time you have found and opened this manual, you have already begun to unpack the shipping container.
14811 • January 2005 • System Components Page 3 SYSTEM COMPONENTS Frame The DA5320 module is engineered to operate in a Sigma S5000 Signal Management Frame. This frame provides all the necessary interface components and power for opera- tion of the DA5320 module.
14811 • January 2005 • Module Installation/Removal Page 4 MODULE INSTALLATION/REMOVAL The DA5320 may be installed in any module slot in a S5000 Signal Management System frame.
14811 • January 2005 • Module Installation/Removal Page 5 RP303 BACKPLANE CONNECTOR ASSIGNMENTS - DA5320 RP302 BACKPLANE CONNECTOR ASSIGNMENTS - DA5320 A B C D E F G H I J OCTABUS OUTPUT OCTABUS I.
14811 • January 2005 • Operation Page 6 OPERATION Front Panel Controls/Displays The front panel, shown below, has three distinct functional areas - the Indicator LED’s under the OctaStream logo on the right side; the switch controls, mostly on the left side and the 7-segment display in the middle.
14811 • January 2005 • Operation Page 7 CONTROLS SELECT BUTTON The Select button is used to progress to a lower menu level. If pressed repeat- edly, the display will always return to the idle display (see below) without making any changes to any menu items .
14811 • January 2005 • Operation Page 8 Display Activation To access menus when the Idle Display is showing, press any button. Status Check To check the current status of any parameter, activate the menu display and navigate through the menu to the edit screen for the parameter of interest.
14811 • January 2005 • Operation Page 9 Configurable Parameters/Menu Items Note: What follows is a discussion of the configurable parameters in the DA5320. To view a diagram of the flow of the menu structure with simple operating instructions, see the section of the manual entitled MENU STRUCTURE that follows this discussion.
14811 • January 2005 • Operation Page 10 sent to the ouput may be adjusted immediately prior to being sent to the output connector. These features are detailed in the Output Channel Assignment/Mixing/Gain Control section below. The DA5320 has two additional features that are available to the user to assist in providing quality I/O routing.
14811 • January 2005 • Operation Page 11 Output Channel Assignment/Mixing/Gain Control The sub-menu item is used to configure the routing matrix of defined inputs to spe- cific physical output connectors and the mixing operation of the DA5320. It is located under the main menu item.
14811 • January 2005 • Operation Page 12 any valid NTSC or PAL video signal or AES Digital Audio. The DA5320 will match its ouptut signal timing to be synchronized to this reference. To have the DA5320 match its output signal timing to the internal reference the menu setting must be set to ON.
14811 • January 2005 • Operation Page 13 N on -V olatile C onfiguration P arameter S torage All configuration data can be stored in the FlashROM to preserve it in the event of a loss of power. On power-up, all settings will be returned to their previous settings.
14811 • January 2005 • Menu Structure Page 14 MENU STRUCTURE The following graphic display of the menu structure is provided to give the user an overall view of the commands that are accessible via the front panel controls. Detailed explana- tions of each parameter have been provided above.
14811 • January 2005 • Menu Structure Page 15 Note: around character indicates character will be blinking - data entry mode active ..
14811 • January 2005 • Menu Structure Page 16 SAVE CONFIG TO FLASH DIAGNOSTICS (Status Only) RESET Reset Board Reset All Reset Outputs Reset Inputs Current ON/OFF setting shown.
14811 • January 2005 • Menu Structure Page 17 NOTES.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Sigma DA5320 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Sigma DA5320 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Sigma DA5320, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Sigma DA5320 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Sigma DA5320, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Sigma DA5320.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Sigma DA5320. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Sigma DA5320 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.