1 REVERSE OSMOSIS DRINKING WATER SYSTEM Owner's Manual & Installation Guide 41840 McAlby Court, Suite A, Murrieta, CA 92562 800.451.9343 . Email: sierra@nimbuswater.
2 Congratulations on your purchase of the Nimbus Sierra reverse osmosis base unit. When properly maintained, this unit will provide you with years of trouble-free service. The next sections contain important information on proper care and maintenance.
3 C MAINTENANCE Replacements Replacement part numbers are indicated on the side of each filter cartridge. The table below lists cartridge replacement part numbers as well as part numbers for the other parts you may need to maintain your unit. To order replacements, please call 800-451- 9343 to be directed to an authorized Nimbus dealer.
4 System Performance Feed Water Requirements Daily production rate 42.8 L/d Feed water(3) Potable water (11.3 gpd) Feed pressure 275 kPa, (40psi) to 552kPa (80psi) Efficiency Rating(1) 8.8% Feed temperature 1°C (33°F) to 38°C (100°F) Recovery Rating (2) 18% Total dissolved solids 2,000 mg/L maximum Chlorine 1.
5 Arsenic (abbreviated AS) is a naturally occurring contaminate found in many ground waters. Arsenic is water that has no color, taste or oder. It must be measured by a lab test. Public water utilities must have their water tested for arsenic. You can get the results from your own water utility.
6 The Sierra Limited Warranty extends to the original purchaser of the system. This warranty covers all parts and factory labor needed to repair any Manufacturer-supplied item that proves to be defective in material, workmanship or factory preparation.
7 INSTALLATION Before You Begin The following instructions outline a typical water treatment system installation. Consult local plumbing codes and building regulations as they may pose different or additional requirements for the installation.
8 INSTALLATION Parts 2 Sierra Manifold Unit A. Pre-filter B . Carbon post-filter C . Reverse osmosis membrane filter D . Cartridge Retainer clips (3) E .
9 INSTALLATION Feed Connection Fig.1 A B Options 1. Locate and turn off the angle stop valve on the cold water line feeding the sink where the Sierra unit is to be installed. This valve will usually be located under the sink on the pipe coming out of the wall.
10 Note: The drain saddle assembly must be installed before the 'P' trap. Do not install the drain saddle assembly be- tween the 'P' trap and the wall. 1 . Position drain saddle assembly (Fig. 3) on drain pipe under sink between the P trap and the sink connection.
11 (continued) 2 . Clean off sawdust. Enamel, Porcelain-Over-Steel, or Cast Iron Sink 1. With drill motor place 1/4" masonry drill bit at selected location. Before starting rotation, firmly apply downward pressure until a slight crunching sound is heard.
12 INSTALLATION Push Handle Faucet For easier installation, attach all tubing prior to mounting the faucet. 1. Insert polished faucet base (refer to figure H page 5) onto base of faucet. 2. Install the 1/4” yellow drain tubing onto the 1/4” barb fitting.
13 Determine the most practical under-the-sink location for placement of the Sierra manifold unit and the companion reservoir tank. Ensure that the specific location allows adequate access to the manifold unit for cartridge replacement and to the tank for tank- valve operation.
14 System Activation and Inspection 1. Check all tubing connections to ensure they are firmly seated. CHECK TO SEE THAT THE CARTRIDGE RETAINER CLIPS ARE PROPERLY ENGAGED. The retainer clips must in place during long term, unattended operation of the system.
15 1. Sierra unit and tank are located where they will not be subject to physical impacts or rough contact by heavy objects. 2. Feed water pressure to the unit is no less than 40 psi and no greater than 80 PSI. 3. Ensure the plastic retainer clips are fully engaged.
16 MAINTENANCE Cartridges/Tank 10 Refer to Section B in the Owner's Manual portion of this guide for a suggested replacement schedule. Cartridge Replacement 1. Close the feed water shut-off valve. 2. Close the tank shut-off valve. 3. Open the R/O dispensing faucet.
17 ©Nimbus Water Systems 2007 PN103257.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Sierra SIERRA REVERSE OSMOSIS DRINKING WATER SYSTEM c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Sierra SIERRA REVERSE OSMOSIS DRINKING WATER SYSTEM - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Sierra SIERRA REVERSE OSMOSIS DRINKING WATER SYSTEM, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Sierra SIERRA REVERSE OSMOSIS DRINKING WATER SYSTEM va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Sierra SIERRA REVERSE OSMOSIS DRINKING WATER SYSTEM, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Sierra SIERRA REVERSE OSMOSIS DRINKING WATER SYSTEM.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Sierra SIERRA REVERSE OSMOSIS DRINKING WATER SYSTEM. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Sierra SIERRA REVERSE OSMOSIS DRINKING WATER SYSTEM ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.