Isolated Multi-Dr op ™ Converter Operator’ s Manual Manual No. SG-6048-01 LOGO Isolated Multi-Drop™ Po r t 1 Tx Rx Po r t 4 Tx Rx Po r t 3 Tx Rx Po r t 2 Tx Rx RS485 RS485 RS485 RS485.
The use of unauthorized parts in the repair of the equipment o r tam- pering by unqualified pe rsonnel will r esult in danger ous conditions which may cause sever e personal injury or equipment damage. Follow all safety instructions contained her ein.
Contents Siemens Energy & Automation, Inc. 1 Introduction ........ ................... ....... 1 1.1 Product S ummary......... ...... ....... ...... ....... ... 1 1.2 How to Use This Manual .... ............. .......... 1 2 Setting Up the Converter .
1 Intr oduction Siemens Energy & Automation, Inc. 1 1 Introduction 1.1 Pr odu ct Summary The Siemens Isolated Multi-Dr op TM conver t er is an electr onic device that lets you connect your DO S-based PC to the Siemens SEAbus TM communications network for ACCESS TM devices o n your power distribution system.
2 Setting Up the Converter 2 Siemens Energy & Automation, Inc. 2 Setting Up th e Conver ter 2.1 Ove rvie w Before connecting the converter to y our system, understand the connectors, LEDs and switches.
2 Setting Up the Converter Siemens Energy & Automation, Inc. 3 . Figure 2.4 Rear Panel The BAUD thumbwheel switch selects the data rate for communications. Set the data rate to be consistent with the data rate for your system’ s S EAbus communications network.
3 Installing th e Converter 4 Siemens Energy & Automation, Inc. 3 Installing the Converter 3.1 Getting Ready This section explains how to install the Isolated Multi-Drop converter for your operation. Y ou can install t he converter either dir ectly to a PC or r emotely within switchgear using short-haul or dial-up modems.
3 Installing the Converter Siemens Energy & Automation, Inc. 5 3.3 Connecting Directly to a PC T o connect the Isolated Multi-Dr op converter dir ectly to a PC, you need an RS-2 32 serial cable of not more than 50 feet in length. Make sure the cable is a DCE-DTE cable, not a null modem cable .
3 Installing th e Converter 6 Siemens Energy & Automation, Inc. 3.4 Connecting wit h Short-Haul Modems If the distance between your PC and Isolated Multi-Dr op converter is gr e ater than 50 feet but less than 3.5 miles, you can connect them using short-haul modems and regular telephone cable.
3 Installing the Converter Siemens Energy & Automation, Inc. 7 3.5 Connecting wit h Dial-Up Modems If the distance between your PC and Isolated Multi-Dr op converter is gr eater than 3.
4 T esting ACCESS Devices 8 Siemens Energy & Automation, Inc. 4 T esting ACC ESS Dev ices Y ou can use the Isolated Multi-Dr op converter’ s 15 VDC power output to pr ovide DC power for testing Static T rip III trip units or SAMMS devices.
4 T esting ACCESS Devices Siemens Energy & Automation, Inc. 9 4.3 T esting Static T rip III on Desktop If you are testing a Static T rip III trip unit on a desktop, follow these steps to connect the trip unit to t h e converter for 15 VDC power , while re f erring to Figur e 4.
4 T esting ACCESS Devices 10 Siemens Energy & Automation, Inc. Figure 4.4 Connecting SAMMS Device for T esting T wo-wire cable RS-485 cable rear panel front panel 15VDC OUT + - RS485 + _ + _ RS485.
5 T r ou bleshootin g Siemens Energy & Automation, Inc. 11 5 T roubleshooting If you exper ience communications errors and suspect the Isolated Multi-Dr op converter i s at fault, perform the actions listed below . Before performing these tests: 1.
5 T r ou blesh ooting 12 Siemens Energy & Automation, Inc. NOTE S:.
Appendic es Siemens Energy & Automation, Inc. 13 Appendix A: Block Diag ram The illustratio n below is a block diagram showi ng how the Isolated Multi-Dr op converter operates. The diagram identifies the internal components that make up the converter .
Appendices 14 Siemens Energy & Automation, Inc.
Appendic es Siemens Energy & Automation, Inc. 15 Appendix B: M ounting Dimensions The illustration below shows the mounting dimensions for the Iso lated Multi-Drop conv erter . Use these dimensions to muont the converter to a switchgear panel or to some other location.
Appendices 16 Siemens Energy & Automation, Inc.
Siemens Ener gy & Automat i on, Inc. Switchgear and Motor C ontrol Business P .O. Box 2950 3 Ralei gh, NC 2762 6-0503 Manual No. SG- 6048-01 (Replaces -0 0) 1M 0595FP Printed in U.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Siemens SG-6048-01 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Siemens SG-6048-01 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Siemens SG-6048-01, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Siemens SG-6048-01 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Siemens SG-6048-01, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Siemens SG-6048-01.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Siemens SG-6048-01. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Siemens SG-6048-01 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.