SEARS OWNER'S MANUAL MODEL NO. 390.2514 390.2518 CAUTION: Read and Follow All Safety Rules and Operating Instructions Before First Use of This Product.
READ AND FOLLOW SAFETY INSTRUCTIONS! This is the safety aler'c symbol. When you see this symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury: DANGER warns about hazards that will cause serious personal injury, death or major property damage ff ignored.
CONTENTS Safety .............................................................................................. 2 Warranty/Introduction ................................................................... 3 Pump Performance .............................
MAJOR COMPONENTS / PIPING MAJOR COMPONENTS AND WHAT THEY DO NOTICE: Use Teflon tape supplied with the pump for making all threaded connections to the pump. Impeller and Jet Impeller turns with motor shaft, causing water to fly out from its rim by centrifugal force.
ELECTRICAL Disconnect power before working on pump, motor, pressure switch, or wiring. Motor Switch Settings If the motor can operate at either 115 or 230 volts, it is set at the factory to 230 volts. Do not change motor voltage setting if line voltage is 230 volts, or if you have a single voltage motor.
ELECTRICAL WIRING CONNECTIONS [_.WARNING_ Fire hazard. Incorrect voltage can cause a fire or seriously damage the motor and voids the warranty. The supply voltage must be within ± 10% of the motor nameplate voltage. NOTICE: Dual-voltage motors are factory wired for 230 volts.
INSTALLATION / OPERATION INSTALLATION SEARS jet pumps should be used with Captive Air* Tanks (See Figure 7). I_IMINGpLU8 PRESSURE $WITGH TO,_ICE BUILT-IN ( VALVE __. 1-114" pLASTIC pIp_ pLASTIC FtPE ADAPTER* PUMPTOTANK SIDE VIEW ;ApTNE AIF_ TANK Figure 7 For mounting pump to tank, purchase tank fittings Kit No.
SERVICE MAINTAINING YOUR PUMP Lubrication It is not necessary to lubricate the pump or its motor. The motor bearings are lubricated for life. The mechanical shaft seal in the pump is water lubricated and self-adjusting. Draining for Winter When the pump is to be disconnected from service, or is in dan- ger of freezing, it must be drained.
SERVICE C. With finger pressure press seat firmly and squarely into cav- ity. See Figure 12A. Polished face of seat faces inside of pump. If seat will not locate properly, place cardboard washer over polished face and use piece of 3/4" standard pipe for press- hag purposes.
REPAIR PARTS 29 28 I 1 / 26 2 3 3A 7 8 lO 25 25A 23 766 1194 22 21 19 20 ]0.
REPAIR PARTS 1/2 HP 3/4 HP Key Model Model Part No. 390,2514 390.2518 Description 1"* 2 3* 3A 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21" 22 23 24 25* 25A* 26 27 28* 29 J218-953C 17351-.
TROUBLESHOOTING CHART PROBLEM POSSIBLE CAUSES REMEDIES Motor will not run. 1. Disconnect switch is off. 1. Be sure switch is on. 2. Fuse is blown. 2. Replace fuse. 3. Starting switch is defective. 3. Replace starting switch. 4. Wires at motor are loose, 4.
13.
14.
15.
SEARS OWNER'S MANUAL MODEL NO. 390.2514 390.2518 The model number of your Shallow Well Jet Pump will be found on the pump body. When requesting service or ordering parts, always give the followin.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Sears 390.2514 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Sears 390.2514 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Sears 390.2514, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Sears 390.2514 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Sears 390.2514, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Sears 390.2514.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Sears 390.2514. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Sears 390.2514 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.