1. About Y our System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 1 2. Remote T ransmitters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
The ScyT ek Vision Guard 8000 is a combination vehicle security and remote starting system f eaturing a built-in "ScyNet Network P ort" that allows direct connection of optional accessory modules and a PC interface off ering expanded system operation.
Standard Remote Transmitter Description The VisionGuard 8000 is compatible with the optional 5-button R emote T ransmitters used to control system operations. Note : Using the optional PC or P ocket PC interface with the network softw are, it is possible to reconfigure the functionality of the tr ansmitter buttons.
Adding/Replacing Transmitters T o replace lost or stolen transmit ters or to add additional transmitters into the system, ha ve all desired transmit ters ready and follow the steps below . Note : Up to 4 one-wa y transmitters can be progr ammed to operate the system.
Page 4 - VisionGuard 8000 True Color 2-way Camera Ready Remote Transmitter Description The VisionGuard 8000 True Color 2-way LCD remote transmitter, is offering increased range and confirmation of any activated features. Button 1 Arms the system. Button 1 also locks the doors when the system is in Valet Mode.
VisionGuard 8000 - Page 5 5. The siren will chirp 3 times to indicate system has exited programming mode. System Confirmation The 2-wa y transmitter's confirmation f eature allows the current vehicle status to be displayed at any time. T o display system status: Press and hold Button 4 until the display shows CON.
Page 6 - VisionGaurd 8000 Programable Functions using the LCD Transmitter Pressing and holding transmitter button 4 will scroll through several transmitter programable options. CHIRP T o set the siren’ s confirmation chirps ON or OFF : 1.Press and hold button 4 until the icon “chirp” appears.
VisionGaurd 8000 - Page 7 C a m e r a F e a t u r e s.
VisionGuard 8000 - Page 8.
VISIONGAURD 8000 - Page 9 Remote Arming The system monitors 5 independent areas ( zones ) while armed: doors, hood/ trunk, shock sensor , optional sensor input, and the network port for future expansion. T o Arm the System: 1. T urn off the ignition. 2.
Page 10- VisionGaurd 8000 Tamper Alert If the system was triggered while awa y , the LED will flash to indicate which zone triggered the system after disarming and turning on the ignition.
VisionGaurd 8000 - Page 11 Panic Mode In the event of an emergency the tr ansmitter’s remote P anic feature can be used to instantly trigger the alarm. T o activate the P anic Mode: 1. Press and hold Button 1 for 3 seconds. · The alarm will sound. · The parking lights will flash.
Page 12- VisionGaurd 8000 T o set the Emergency Override Code: 1. T urn on ignition. 2. Within 5 seconds, press the v alet switch 5 times. · The siren will provide one long chirp, indicating that y ou have entered Progr amming. 3. Press the v alet switch 4 times.
VisionGaurd 8000 - Page 13 Remote Starting T o Remote Start the S ystem: 1. Be sure the system is not in V alet Mode. 2. Press and hold Button 4 on one wa y remote or button 3 on LCD remote for three seconds. · The parking lights will flash 4 times and turn on.
Page 14- VisionGaurd 8000 Turbo Timer Feature The T urbo Timer feature allows vehicles with turbocharged engines to remain running after the ignition key is removed, f or proper cool-down of the turbocharger . The T urbo Timer feature requires connection to the vehicle’ s parking brake wire.
VisionGaurd 8000 - Page 15 E x t e n d e d F e a t u r e s Ignition Door Locking F or added safety , the Ignition Door Locking feature allows v ehicles equipped with power door lock systems to automatically lock the doors when the ignition is turned on.
Page 16 VisionGaurd 8000 1. Thoroughly read and become familiar with the installation instructions bef ore beginning the installation. 2. R eview system contents: Main Unit One 5-Button one-w ay Remot.
VisionGaurd 8000 - Page 17 Mounting the Control Unit The control unit must only be mounted in the interior of the vehicle. Do not mount the main unit in the engine compartment.
Page 18- VisionGaurd S y s t e m W i r i n g 6-Pin Starter Harness Pin 1 RED WIRE A : Main Power Input A (+). Connect to the battery or constant power wire at the ignition switch with a minimum 25 Amp supply . R emo v e the fuse until the installation is complete and all wiring is check ed.
VisionGaurd 8000- Page 19 when the door is open. This type of door circuit is usually found on F ord vehicles. Pin 12 GREEN WIRE : Negativ e Door Input (-). Connect to the door switch circuit wire that shows ground when the door is open. Pin 13 WHITE/BLACK WIRE : Hood Pin Input (-).
Page-20 VisionGaurd 8000 Jumper Selection Carefully separ ate the top and bottom halves of the main unit case. Once the cov er is removed, the parking light polarity jumper will be visible next to the parking light relay . Set the jumper for the correct polarit y output as described below , then reassemble the main unit case.
VisionGaurd 8000 - Page 21 Entering System Programming This system is compatible with both the optional LCD tr ansmitter or the standard FM transmit ter , all system programming can be perf ormed using either one. T o enter System Progr amming: 1. T urn on ignition.
Page- 22 VisionGaurd 5. Ignition Door Unlocking. Selects whether or not the system automatically unlocks the doors when the ignition is turned off . The Ignition Door Locking f eature may be programmed to unlock all doors or the driver’ s door only .
VisionGaurd 8000 - Page 23 8. Passive Door Locking. Selects whether or not the system will automatically lock the doors during P assive Arming and Auto Rearming mode. 9. Passive Arming Entry Delay. When selected, the siren will chirp for 10 seconds before sounding if a door is opened.
Page-24 VisionGaurd 8000 Diesel Engine. Sets the engine type f or Diesel and monitors the glow plug input to make sure the glow plugs are warm before cr anking the starter . If the glow plug wire is not connected, the built-in timer waits 15 seconds before automatically cr anking the starter .
VisionGaurd 8000 - Page 25 W i r i n g D i a g r a m s TO POSITIVE DOME LIGHT +12V Black/White (-) DOME LIGHT OUTPUT TO NEGATIVE DOME LIGHT +12V Black/White (-) DOME LIGHT OUTPUT P ositive Dome Light .
Page-26 VisionGaurd 8000 Negative T rigger Positive T rigger (using inverter or relays) R everse P olarity V acuum Adding Actuators F ollow the diagrams below for connecting basic door lock systems. F or T wo Stage door lock systems (separately unlocks driv er and passenger doors) see following pages.
VisionGaurd 8000 - Page 27 T w o S t a g e D o o r L o c k D i a g r a m s T wo Stage Negative T rigger T wo Stage P ositive T rigger The VisionGuard 8000 is equipped with a dedicated P assenger Unlock output allowing T wo Stage Door Lock operation. When connected as shown below , disarming the system will unlock only the driver’ s door .
Page-28 VisionGaurd 8000 T w o S t a g e D o o r L o c k Diagrams c o n t ’ d T wo Stage R everse P olarity T wo Stage Adding Actuators.
VisionGaurd 8000 - Page 29 FCC ID: OARRXAM2000 This device complies with P art 15 of FCC Rules. Operation is subject to the f ollowing two conditions: 1) This device may not cause harmf ul interference.
Page-30 VisionGaurd 8000 S t a r t e r D i a g n o s t i c s Starter doesn’t start and parking lights flash: 3 Times - Engine RPM not detected Hood T rigger is active 4 Times - Brak e T rigger is active 5 Times - Unit is in V alet (service) mode, and start is disabled.
VisionGaurd 8000 - Page 31.
ScyTek Electronics 11627 Cantara Street North Hollywood, CA 91605 © ScyT ek Electronics 2006 VisionGuard 8000 r1 4/06 W i r i n g D i a g r a m ScyNet Blue Star t (-) Green Emer gency brak e(-) Anten.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Scytek electronic 8000 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Scytek electronic 8000 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Scytek electronic 8000, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Scytek electronic 8000 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Scytek electronic 8000, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Scytek electronic 8000.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Scytek electronic 8000. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Scytek electronic 8000 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.