RuggedSwitch ® RSG2300 32-Port Managed Ethernet Switch with 4 Modular Gigabit Uplink Ports Installation Guide November 12, 2008 www.ruggedcom.com RuggedCom Inc.
Copyright COPYRIGHT © 2008 RuggedCom Inc. ALL RIGHTS RESERVED Dissemination or reproduction of this document, or evaluation and communication of its contents, is not authorized except where expressly permitted. Violations are liable for damages. All rights reserved, particularly for the purposes of patent application or trademark registratio n.
Federal Communications Commission Radio Frequency Interference S t atement This equipment has been tested and found t o comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules.
Table of Contents T able of Content s Copyright ........................................................................................................................... 2 Federal Communications Commission Radio Frequency Interference Statement ....
Table of Figures 5 © 2008 RuggedCom Inc. All rights reserved Rev100 T able of Figures Figure 1: 19" Rack Front Mount (connectors at front) ....................................................... 9 Figure 2: 19" Rack Rear Mount (connectors at rear) .
.
Product Overview 1 Product Overview 1.1 Functional Overview The RuggedSwitch ® RSG2300 is an industrially hardened, fully managed, modular Ethernet switch specifically designed to operate reliably in electrically harsh and climatically demanding utility s ubstation and industrial environments.
Product Overview RuggedRated™ for Reliability in Harsh Environments • Immunity to EMI and heavy electrical surges o Zero-Packet-Loss™ Technology o Meets IEEE 1613 Class 2 (electric utility subst.
Product Overview 1.3 Mounting Flexibility RSG2000 series products have been designed with maximum mounting and display flexibility. Customers can order an RSG2000 series switch that can be mounted in a standard 19” rack, 1” DIN Rail, or directly onto a panel.
Product Overview 1.4 Ethernet Panel Description The Ethernet connector panel of the RSG2300 is organized into three banks of eight 10/100Tx copper ports, for a total of 24 fixed 10/100Tx ports, and four modular slots, whose configuration may be selected at the time the unit is ordered.
Product Overview 1.4.1 Fiber Optic Transceiver Orientation and Connection Depending on the order code of the product, the RSG2300 can be equipped with several different types of fiber optic ports. The Transmit (TX) and Receive (RX) connections of each port must be properly connected and matched for proper link and operation.
Product Overview Figure 7 through Figure 11 show front and top views of the fixed fiber transceiver modules supported by RuggedSwitch ® . Note that when the daughter card containing transceiver modules is installed in the unit, most of the body of the module as shown in top views below will not be visible.
Product Overview 1.5 Display Panel Description RSG2000 series products are equipped with a versatile display panel, shown in Figure 12 , which provides real-time status information for each port and for the chassis as a whole, to allow simple diagnostics and troubleshooting.
Product Overview The port LEDs can be cycled between three display modes: Status, Duplex, and Speed. Pushing the Mode button causes the display mode to be cycled.
Installation 2 Inst allation 2.1 Rack Mounting The RSG2000 family of products can be rack mounted using the included rack mount adapter assemblies shown in Figure 13 . Secure the rack mount adapter to the front side of the chassis using the included black PAN head Philips screws in the positions shown in Figure 14 .
Installation 2.2 Panel and DIN Rail Mounting RSG2000 series products can be ordered as panel/DIN mount chassis. Both options involve the use of the panel/DIN adapters to be mounted on each side of the chassis enclosure.
Installation 2.3 Power Supply Wiring and Grounding The RSG2000 family supports dual redundant power supplies, “Power Supply 1” (PS1) and “Power Supply 2” (PS2). The connections for PS1, PS2 and the fail- safe relay are located on the terminal block as shown in Figure 16 and Figure 17 .
Installation The RSG2000 Family chassis ground connection, shown in Figure 18 , uses a #6- 32 screw. It is recommended to terminate the ground connection in a #6 ring lug, and to use a torque setting not exceeding 15 in·lbs (1.7 Nm). Figure 18: Chassis Ground Connecti on #6 rin g lu g stainless steel standoff #6-32 screw with ext.
Installation 2.3.1 AC Power Supply Wiring Examples Figure 19: AC Power supply wiring examples Notes: • 125/230VAC rated equipment: A 250VAC appropriately rated circuit breaker must be installed. • Equipment must be installed according to the applicable country wiring codes.
Installation 2.3.2 DC Power Supply Wiring Examples Figure 20: DC Power supply wiring examples Notes: • 125/250VDC rated equ ipment: A 300VDC appropriately rated circuit breaker must be installed. • A circuit breaker is not required for 12-24 or 48 VDC rated power supplies.
Installation 2.3.3 Dual Power Supplies – DC and AC Inputs Figure 21: DC And AC po w er supply wiring examples Notes: • 125/250VDC rated equ ipment: A 300VDC appropriately rated circuit breaker must be installed. • 110/230VAC rated equipment: A 250VAC appropriately rated circuit breaker must be installed.
Installation 2.4 Dielectric Strength (HIPOT) Testing For dielectric strength (HIPOT) testing in the field, users must remove the metal jumper located across terminals 2, 4, and 6 of the power supply terminal block.
Installation 2.5 Failsafe Alarm Relay Wiring and Specifications The “Failsafe” output relay is provided to signal critical error conditions that may occur on RS2000 series products. The contact s are energized upon power-up of the unit and remain energized unless a critical error occurs.
Installation 2.6 Console Port Wiring An RS232 console port for configuration and management of the device is located on the LED display module shown in Figure 24 . This port is intended to be a temporary connection during initial configuration or troubleshooting and allows for direct serial access to t he management console.
Installation 2.7 Gigabit Ethernet 1000Base-TX Cabling Recommendations The IEEE 802.3ab Gigabit Ethernet standard defines 1000 Mbit/s Ethernet communications over distances of up to 100 meters using all 4 pairs in category 5 (or higher) balanced unshielded twisted-pair cabling.
Installation 2.8 Pluggable optics – Installation, removal, and precautions The RSG2300 can be ordered with two pluggable optical form factors: SFP (Small Form-factor Pluggable), and GBIC (GigaBit Interface Converter).
Installation Both SFP and GBIC modules should gently slide into their ports and should lock in place when fully inserted. Dust covers should be in place when installing the modules, and should always be in place when cables are not connected. Diagrams of both SFP and GBIC modules are provided in Table 1 as a guide to the orientation of each type.
Technical Specifications 3 T echnical Specifications 3.1 Power Supply Specifications Input Range Power Supply Type Min Max Fuse Rating Max . Po wer Consumption 3 12 – 24 VDC 10 VDC 36 VDC 6.3A(F) 2 48 VDC 36 VDC 59 VDC 2A(T) 2 HI (125/250 VDC) 1 HI (110/230 VAC) 1 88 VDC 85 VAC 300 VDC 265 VAC 2A(T) 1,2 25W Notes: 1.
Technical Specifications 3.4 Copper Ethernet Port Specifications The RSG2300 features a fixed set of three fixed banks of eight 10/100Tx copper ports each, and can be ordered with additional 10/100Tx ports in slots 1 and 2, and 10/100/1000Tx ports in slots 3 and 4.
Technical Specifications FX04 SM ST 9/125 1310 -15 -8 -32 -3 20 17 FX05 SM SC 9/125 1300 -15 -8 -31 -7 20 16 FX06 SM LC 9/125 1310 -15 -8 -34 -7 20 19 FX07 SM SC 9/125 1310 -5 0 -34 -3 50 29 FX08 SM LC 9/125 1310 -5 0 -35 -3 50 30 FX09 SM SC 9/125 1310 0 5 -37 0 90 37 FX10 SM LC 9/125 1310 0 5 -37 0 90 37 3.
Technical Specifications 3.6 Type Test Specifications 3.6.1 IEEE 1613 (C37.90.x) EMI Immunity Type Tests Test Description Test Levels Enclosure Contact +/- 8kV IEEE C37.90.3 ESD Enclosur e Air +/- 15kV IEEE C37.90.2 Radiated RFI Enclosure ports 35 V/m Signal ports +/- 4kV @ 2.
Technical Specifications IEC 61000-4-8 Magnetic Field Enclosure ports 40 A/m continuous, 1000 A/m for 1 s N/A D.C. Power ports 30% for 0.1s, 60% for 0.1s, 100% for 0.05s N/A IEC 61000-4-29 30% for 1 period, 60% for 50 periods N/A IEC 61000-4-11 Voltage Dips & Interrupts A.
Technical Specifications 3.6.3 Environmental Type Tests Test Description Test Levels Severity Levels IEC 60068-2-1 Cold Temperature Test Ad -40°C, 16 Ho urs N/A IEC 60068-2-2 Dry Heat Test Bd +85°C,.
Technical Specifications 3.8 Mechanical Specifications Parameter Value Comments Dimensions 18.29 x 12.14 x 1.75 in (464.57 × 308.36 × 44.45 mm) (Length x Width x Height) with mounting brackets installed Weight 10 lb (4.5 kg) Enclosure 18AWG galvanized steel Figure 30: RSG2300 Mechanical Dim ensions 34 Rev100 © 2008 RuggedCom Inc.
Agency Approvals 35 © 2008 RuggedCom Inc. All rights reserved Rev100 4 Agency Approvals Agency Standards Comments CSA CSA C22.2 No. 60950, UL 60950 Passed CE EN 60950, EN 61000-6-2 CE Compliance is c.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté RuggedCom RSG2300 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du RuggedCom RSG2300 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation RuggedCom RSG2300, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le RuggedCom RSG2300 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le RuggedCom RSG2300, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du RuggedCom RSG2300.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le RuggedCom RSG2300. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei RuggedCom RSG2300 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.