81139 Issue 3 52<$/&+(/7(1+$0 USERS INSTRU CTIONS THIS CAT I 2H APPLIANCE IS FOR USE ON NATURA L GAS G20 AT A SUPPLY PRESSURE OF 20 mbar GB and IE HAND THESE INSTRUCT IO NS TO THE USER.
DESCRIPTION The Royal Cheltenham glass fronted high efficiency live fuel effect inset gas fire has been developed from the successful Roy al Cozy fires LFE using much of the techno logy and components used in the manufact ure of this appliance.
TECHNICA L DATA Heats I nput Rates: High Setting 5.42 kW 18,500 Btu/h (Gros s) Low Setting 2.34 kW 8,000 Btu/ h This fire will run for 5.4 hour s on one therm of g a s on hig h setti ng . LOCATION OF COM BU S TI BL E SHE LV ES ABOVE F IRE SIDE OF F IRE Min.
DISMANTLING THE F IRE BED FOR CLEANING (see fig.3, 4 & 5) Allow the appl iance to cool for 1 hour before handling an y components. Remove the controls cover and unscrew the two wing screws securi ng the canopy in place as shown in (fig 3). L ift the canopy off the appliance and place to one side.
COAL LAYING INSTRUCTION S Lay the four front coals diagonally with the stepped corner sit ting on the sim ulated coal front and the small corner notch at the rear. L a y a further row of fo ur coal s behind the fro nt r ow with stepped corners in the rear corners of the front row, the two centre coals having no t ches in the rear top corners.
Note: Should any ‘coals’ or the coal bed become damaged, lost or broken, only the correct replacem en ts must be obtained and fit ted before the appl iance is used. E x tra ‘coals’ etc. must not be added to the coal bed. The coal bed must alway s be assemb led as detai led.
REGI STRATI ON RECORD Purchaser’ s Name ______________ ____ ____ ____ ____ ____ ____ _____ ___ ____ and Address ______________ ____ ____ ____ ____ ____ ____ _____ ___ ____ ______________ ____ ____ _.
81140 Issue 3 52<$/&+(/7(1+$0 INSTALLATION AND SERVICING INSTRUCTIONS THIS CAT I 2H APPLIANCE IS FOR USE ON NATURAL GAS G20 AT A SUPPLY PRESSURE OF 20 mbar GB and IE HAND THESE INSTRUCTIONS .
DESCRIPTION The Roy al Chelt enham g l ass fronted high efficiency liv e fuel effect inset gas fire has been developed from the successful Roy a l Cozy fires.
INSTALLATION REGULATIONS AND REQUIREMENTS I n the interests of both the Law and of Safety , this appliance must only be installed by a competent person in accordance with the current Gas S afety (Installation and Use) Regulations or t he rules in force and t he manufacturer’ s instructions.
Page 4 Clearance to side (tim ber surrounds etc .) Minimum cl earance required to any combustible materia l to the side of the appliance must be 150mm. Clearance to shelves. Minimum clearances t o undersides of a 150mm deep combustible shelf from the hearth must be 830mm.
Page 5.
INSTALLATION USING A 5" DIAMETER METAL F LUE BOX Page 6 Important: The Flue restrictor pl ate must be removed see F ig 10. When the metal flue box is to be built-in as a false chimney breast usin.
INSTALLATION OF THE APP LIANCE Check that th e chimney conform s to the required specificati ons as previously stated. Ex amine the condition and carry out any remedial work, if the flue has been used for solid fuel it should be swept and a smoke test carried out to check that sati sfactory smoke clearance has been established.
Page 7 a (ii) If the spacer frame is to be used, attach the fram e to the rear of the appliance using either the screws and captive nuts removed from the appliance or supplied in the fixing kit, see fig 8.
Page 8.
Page 9.
Page 10.
Page 11.
Page 12.
CHECKING OP ERATION OF F IRE Purge the air from the appliance by rotating the control to the ig nition position, push the control to allow the air in the pipework to be purged, push the piezo to ignite the Oxy /pilot. Check that the electrode is sparking between the tip of the thermocouple and continue until a pilot flame has been established.
Complete the registration section at the end of this booklet. Advise that any component part of this appliance be guaranteed ag ainst defective workmanship or faulty materials for a period of twelve months from the date of purchase.
Page 15.
SHORT PA RTS LIST For spares contact the manufacturer at the address overleaf. DESCRIPTI ON CROSSLEE No GC No Piezo Ig niter 40245 397 686 Control Knob 40232 170 014 Control Valve 42143 378 092 Oxy/Pi.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Royal U19019 G20 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Royal U19019 G20 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Royal U19019 G20, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Royal U19019 G20 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Royal U19019 G20, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Royal U19019 G20.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Royal U19019 G20. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Royal U19019 G20 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.