Roll Laminator Service Manual MODEL:RSH-380SL.
3 ~ 3 4 ~ 10 4 ~ 6 6 ~ 7 7 ~ 9 9 ~ 10 11 ~ 11 12 ~ 14 12 ~ 12 13 ~ 13 13 ~ 13 13 ~ 13 13 ~ 13 13 ~ 14 14 ~ 14 15 ~ 16 17 ~ 19 20 ~ 25 26 ~ 29 30 ~ 33 4.Adjustments …………………………………………………………………………………… 5.
Safety Precaution 1. Safety Precautions Failure to comply any of the following safety procedures could result in serious injury. Please read the instructions carefully and keep for future reference. 1. Only a licensed electrician should install wiring and outlet for the laminator.
Note: While repairing: a. Make sure the power plug is unplugged from the power outlet. b. Open both side covers and rear cover. c. Be sure to follow the steps below in order. 2.1 Rollers Not Heating CAUSES: 1. Improper laminating mode. 2. Heating wire is not connected to the main PCB.
2. Blown (burnt) wire fuse (T/Fuse). a. Replace the T/Fuse wire located on the left-hand side. 3. Defective Bi-Metal. a. Replace the Bi-Metal 4. Defective heater. a. Using the multi-meter, test the continuity of the heater. If it fails, replace the heater.
5. Defective Main PCB. a. Replace the PCB Main. 2.2 Rollers Over Heating CAUSES 1. Heat sensor is reversed on the PCB Main. 2. Defective T/Fuse wire. 3. Defective heater. 4. Defective main PCB. MEASURES 1. Wires for lower and upper heat sensors are reversed on the main PCB.
4. Defective Main PCB. a. Replace the PCB Main. 2.3 Rollers Not Running CAUSES 1. No power to the unit. 2. The main switch is close. 3. Opened safety cover. 4. Film is jammed on the rollers. 5. Disconnected motor wire. 6. Defective main motor. 7. Defective main PCB.
4. Film is jammed on the rollers. a. Un-jam the film using a combination of the pressure lever and reverse button. 5. Disconnected motor wire. a. Check the motor wire connection with PCB.
7. Defective main PCB. a. Replace the main PCB. 2.4 No Main Power CAUSES 1. No electricity. 2. Blown main fuse. 3. Disconnected main power wires. 4. Defective transformer. MEASURES 1. No Electricity. a. Double check to insure that you have electricity from your outlet.
4. Transformer is defective a. Replace the transformer. Problem: Straight wave lines across the output. Cause: Excessive front roller pressure. Measure: Loosen the front roller pressure. Problem: Concave waves in the lamination. Cause: Excessive rear (pulling) roller pressure.
Note: While replacing parts: a. Make sure the power plug is unplugged from the power outlet. b. Open both side covers and rear cover. 3.1 Replacing the Right Cover. a. Take out the pressure lever (Figure 1) and four cover screws using Phillips screw driver (Figure 2).
3.4 Replacing the Heaters Note: Cotton or surgical gloves are recommended while handling the heater assembly. a. Disassemble Right and Left Covers (Refer to “ Replacing Right Cover ” and “ Replacing Left Cover ”). b. Take out the heater brackets on each side by loosening screws (Figure 8, 9).
.2 Adjusting front and rear roller s Pressure • Use Screwdriver to adjust the roller pressure: C.W – Increase pressure. C.C.W – Decrease pressure. 1. Using Push-Pull Scale , measure 3 spots as shown on Figure B &C: Front roller should be 5~6 and back rollers should be 6~8.
021LR0001A COVER-L ABS PA-765 UL94 V-0 PANTON 431 125LR4001A HANDLE-TENSION S45C Cu+Ni+Cr 138LR4012A SPRING-TENSION SWP Ф 3.2 12200X022A BEARING-RADIAL 15*28 141LR4033A PLATE-PRESSURE,PULL SPCC 3.0T 138LR4015A SPRING-PRESSURE SWP Ф 2 141LR4032A PLATE-PRESSDURE,LAMI SPCC 3.
141LR4043A FRONT TABLE SAFETY LEVER SPCC 1.5T 013LR4004A SAFETY FRAME SPCC 021LR3024A SAFETY-COVER PC 3.0T 014LR3001B TABLE-FRONT AL6063 133LR3001A ROLLER-LAMI STPG ORG 223LR3001H HEATER ASS'Y FC.
350LR3043A PCB-SUB ASSY FR-4 36600X001A FUSE-BLOCK FB66 LITTLE FUSE TRIAD INC 32500X0008 FUSE-MAIN 65TS AC250V 10A EU,AU,KR,CH,UK,EU(N),BR 32500X0005 FUSE-MAIN 65TS AC250V 20A TW,CUL,JOL,JAP 021LR3018A COVER-R ABS PA-765 UL94 V-0 PANTON 431 138LR4001A SPRING-CUTTER CROSS SWRH Φ 0.
No. Part No. Part Name 1 021LR0001A COVER-L 2 125LR4001A HANDLE-TENSION 3 138LR4012A SPRING-TENSION 4 12200X022A BEARING-RADIAL 5 141LR4033A PLATE-PRESSURE , PULL 6 138LR4015A SPRING-PRESSURE 7 141LR4.
16 7. Wire Diagram 1 2 3 4 5 6 78 A B C D 8 7 6 5 4 3 2 1 D C B A T i tle Numbe r Revision Si ze A2 D a t e : 6 -M ar -2 00 9 S he e t o f Fi le: D: PR O GR A M FI L ES EXAMPLES R SL-3 8 2S CI RS L-3 82 S C I.
1. Wire Main. 6. Wire Power Transformer In 2. Wire Power 7. Wires Power Transformer Output 3. Wire Heater , up 8. Wire Fuse 4. Wire Heater , low 5.
18 SUB PCB Wire Bimetal Wire Up Heater Wire Lo Heater Bimetal(135 ℃ ) Power Cord Fuse Main Motor Wire Sensor.
19 Wire T/Fuse (133 ℃ ) Wire Safety S/W Wire Motor Micro Switch.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Royal Sovereign RSH-380SL c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Royal Sovereign RSH-380SL - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Royal Sovereign RSH-380SL, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Royal Sovereign RSH-380SL va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Royal Sovereign RSH-380SL, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Royal Sovereign RSH-380SL.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Royal Sovereign RSH-380SL. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Royal Sovereign RSH-380SL ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.