Manuel d'utilisation / d'entretien du produit RHFE-431FA du fabricant Rinnai
Aller à la page of 60
Owner’s Operation and Installation Manual RHFE-431FA Ⅲ ENERGYSAVER GAS DIRECT VENT WALL FURNACE INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. This appliance may be installed in an aftermarket, permanently located, manufactured home (USA) or mobile home, where not prohibited by local codes.
W ARNING IMPROPER INST ALLA TION, ADJUSTMENT , AL TERA TION, SERVICE OR MAINTENANCE CAN CAUSE PROPER TY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE, REFER TO THE OWNER'S INFORMA TION MANUAL PROVIDED WITH THIS APPLIANCE. INST ALLA TION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INST ALLER, SERVICE AGENCY OR THE GAS SUPPLIER.
FEA TURES OF THE RHFE-431F A UNITS SAFETY DEVICES – 1 – ◆ Clean Heating Forced Flue T ype ◆ Easy Operation One-T ouch Ignition ◆ Sensible T emperature Control Feature ◆ Comfortable Room T .
– 2 – Overcurrent Prevention Device: This is a 3 amp. glass fuse found on P .C. board. Design to shut unit down in case of overcurrent. If fuse blows all indicator lamps will be “ OFF ” . Power Outage Safety Device: This safety device cuts off gas passage and stops operation.
IMPORT ANT POINTS / USAGE AND INST ALLA TION MUSTS – 3 – Unpack heater and check for damage. (DO NOT INSTALL DAMAGED HEATER.) If heater is damaged, contact your supplier for advise. Before installing a heater, check the label for the correct gas type (see label on heater).
– 4 – 12. YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM WITH THE HEATER. 13. LPG containers must not be installed indoors.
DIMENSIONS – 5 – 21 13/16" (554mm) 19 15/16" (506mm) 8 7/16"(214mm) Power supply cable 29 1/2" (750mm) 8 9/16" (217mm) 9 5/8" (245mm) Exhaust at rear of unit 3 7/16" (88mm) 11 " (280mm) R8.
SPECIFICA TIONS – 6 – MODEL RHFE-431FA -P PROPANE BTU/h MIN. CLEARANCES INPUT OUTPUT SIDE TOP LO:110.5 HI:141.3 LO:110.5 HI:141.3 FRONT 2 " (50mm) 10 " (250mm) 40 " (1m) 40 " (.
– 7 – Safety Devices Noise Level Range HI LOW 38 32dB(A) TYPE SPECIFICATIONS FOR VENT SIZES S Thin Walls Mobile Home Wood Walls Wood/Brick Brick/Block Special 3 " 4 1/2 " (75 115)mm 4 1/.
SAFETY POINTS – 8 – Do not restrict the warm air discharge by placing articles in front of the heater . This appliance must not be used for any purpose other than heating. Do not install the heater in an unusually dusty area. Do not allow anyone to sit on or lean against the appliance.
– 9 – SAFETY POINTS Keep flammable materials, trees, shrubs, etc., away from the flue terminal. Do not allow anyone to poke articles through the louvers. Y oung children should be supervised at all times. Hand or body contact with the louvers should be avoided.
VENT TERMINAL COMBUSTION/ EXHAUST GETTING T O KNOW YOUR NEW RHFE-431F A – 10 – WARM AIR OUTLET HUMIDIFIER REMOVE BOTTOM COVER AND PULL OUT TO REFILL BOTTOM COVER HOLD BOTH SIDES AND PULL TOWARD YO.
CONTROL P ANEL – 11 – CHILD SAFETY LOCK Lamp is "green" when this feature is on. TEMPERATURE DISPLAY Set temperature lamp stays on. Current room temperature flashes. FILTER LAMP Flashes when filter is dirty. OPERATION LAMP This lamp turns "green" when power is on.
– 12 – CUT -A W A Y DIAGRAM.
– 13 – NOTICE BEFORE INST ALLA TION The heater must be installed by a qualified service person according to this installation instruction. Check your local building codes for the proper method of installation. In the case of absence of local codes, this heater should be installed in accordance with the National Fuel Gas Code ANSI Z223 1.
– 14 – INST ALLA TION INSTRUCTIONS Flue Manifold 1 Back Spacer Set Flue Locking Clamp Flue Lock Stopper Insulation Clip Hose Clip Plastic tie for air inlet (M4 20) For Flue Lock Stopper For Flue Manifold Wall Bracket Screws (M4) (M4.
– 15 – GAS CONNECTION 1. The gas supply line shall be gas tight, sized and so installed as to provide a supply of gas sufficient to meet the maximum demand of the heater without loss of pressure. 2. A shut off valve (and appliance connector valve) should be installed in the upstream of the gas line to permit servicing.
– 16 – VENT LOCA TION FITTING TOP SP ACER + W ALL CLIP FLUE MANIFOLD POSITION Center of hole for flue manifold can be drilled anywhere within the shaded area. (To avoid studs, etc.) FOR WEATHERBOARD WALLS DRILL THROUGH CENTER OF WEATHER BOARD FROM OUTSIDE, THEN DRILL FROM INSIDE THROUGH PLASTER- BOARD.
– 17 – VENT TERMINA TION CLEARANCES INSIDE CORNER DETAIL FIXED CLOSED OPERABLE FIXED CLOSED OPERABLE B B B A J B M C F B B E D L G A H K I X AIR SUPPLY INLET V VENT TERMINAL AREA WHERE TERMINAL IS.
– 18 – LOCA TION / CLEARANCES When positioning the heater the main points governing the location are: 1. Flueing 2. Warm air distribution This heater is not designed to be build in. The flue terminal should be positioned away from flammable materials.
– 19 – SNOW AREAS FIT BACK COVERS (SIDES ONLY) Fit back covers (sides only) as shown below. In areas subject to heavy snowfall, keep snow clear of flue terminal at all times. STANDARD INSTALLATION OF FLUE MANIFOLD. Diagram below shows minimum clearances and distances from obstructions.
– 20 – SLEEVE AND MANIFOLD INST ALLA TION METHOD FOR STANDARD WALLS 1. Disassemble Manifold from Sleeve. The flue consists of 3 parts, sleeve, inside connectors and tube, outside terminal; (dis-assembly by pulling hard on outside terminal and inner connections, then pull sleeve off outer terminal.
– 21 – 5. Check rubber seal is in place on terminal. *For weather board walls, add spare rubber seal provided to compensate for weather board angle. 6. Installation of Terminal From outside, insert terminal into sleeve with the “ A ” mark at the top.
– 22 – FITTING UNIT AIR INLET HOSE 2. Fit the locking clamp over connection between sliding tube and manifold. Engage the hook and rotate it until it snaps against the body of the clamp. 3. Fit the screw clamp between the sliding tube and the flue elbow.
– 23 – If necessary, the unit can be levelled using the adjustable legs under the front right and left hand side legs. INSTRUCT CUSTOMER ON USE OF HEATER When you are satisfied that the appliance is operating correctly, explain operation of heater to the customer.
– 24 – OPERA TING INSTRUCTION LABEL ENERGYSA VER RHFE-431F A FOR YOUR SAFETY READ BEFORE OPERA TING OPERA TING INSTRUCTIONS TO TURN OFF GAS T O APPLIANCE W ARNING: If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life.
– 25 – ADDITIONAL CUST OMER OPERA TING INFORMA TION IGNITION Make certain the heater is connected into both the gas and the electric power. Depress the ignition ON/OFF button slowly and firmly.
– 26 – ROOM TEMPERATURE DISPLAY Temperature is indicated by the L.E.D. display on the control panel. The room temperature is indicated by the flashing L.E.D., and the set temperature by the steady L.E.D. When the set temperature is reached, the flashing L.
– 27 – This equipment is for 120 V AC (60Hz) only. Do not use power source other than what is listed. Caution ● Should the type of gas or power source be different, please contact your dealer. Using a different type of gas or power source may affect the performance or may be dangerous.
– 28 – ■ Insert a board under the unit when placing on carpeted floor ! ! ! This heater may be installed on combustible flooring. When the heater is installed directly on carpeting, tile or othe.
– 29 – Before the Cold Season Begins ■ Check the air supply/exhaust connection. ● Before using this heater, inspect the air supply/exhaust connection to make sure the pipe is not disconnected or bent. ■ Check the main unit and the air supply/exhaust.
– 30 – Adding Water to Humidifier: If the air gets dry, add water to the humidifier tray to add moisture to the air. (1) Remove the bottom cover. Hold both ends of the cover and pull toward you to remove the cover. (2) Pull out the humidifier tray and add water.
– 31 – CAUTION: ● If you continue to use the heater with the filter indicator lamp flashing, the sensor may detect trouble and turn the unit off automatically.
– 32 – TESTING CHECK Testing Unit Purge air from gas line. Refer to pipe sizing chart if in doubt about the size of the gas line. Connection can easily be reached from the top, rear of the unit. Check for leaks, using soapy water after turning gas on.
– 33 – PRE-SER VICE CHECK Before asking for a service call please check the following points. These points are part of the normal operation of the unit. ■ At Ignition: Heater does not operate. Warm air does not flow when the burner lights. Smoke or strange smells are produced on the first trial light up after installation.
– 34 – TROUBLE SHOOTING Your RHFE-431FA requires very little maintenance, simply clean the rear fan filter once a week and wipe the outer case and louver section with a damp cloth. General maintenance items are not covered under unit's warranty.
– 35 – MAINTENANCE / SER VICE MAINTENANCE SUGGESTIONS This heater has been designed and constructed for a long performance life when installed and operated properly under normal conditions. Regular inspections, as outlined in this section, are strongly recommended as means of keeping your heater operating efficiently throughout the season.
– 36 – SW6, DIP SWITCH SW1 FM, ADJUST SWITCH 〔 Hi 〕 SW2 FM, ADJUST SWITCH 〔 Lo 〕 SW3 POV, PRESSURE ADJUST SWITCH 〔 Hi 〕 SW5, TEST SWITCH SW4 POV, PRESSURE ADJUST SWITCH 〔 Lo 〕 TH TB AC ER SP 120V OH.
– 37 – W arranty Information Limited Warranty Gas Direct Vent Wall Furnace What is covered? This Warranty covers any defects in materials or workmanship, subject to the terms stated below. This Warranty extends to the original purchaser and subsequent transferees, but only while the product remains at the site of the original installation.
– 38 – Limited Warranty - continued What will Rinnai do? Rinnai will repair any part or component that is defective in materials or workmanship as set forth as follows. All repair parts must be genuine Rinnai parts. All repairs or replacements must be performed by an individual or servicing company that has been authorized by Rinnai.
– 39 – SCHEMA TIC DIAGRAM.
– 40 –.
– 41 –.
– 42 –.
– 43 –.
– 44 – P ARTS LIST.
– 45 –.
– 46 –.
– 47 –.
– 48 – No. PART NAME PART No. QTY. REMARKS 714 TF COVER 556F-524 1 715 FR LEAD 431F-1430 1 716 OVERHEAT SWITCH ES-01174 1 2 6 6 ° FOFF 717 EARTH LEAD 550F-0818 2 719 OHS3 BRACKET 556F-570 1 720 O.
– 49 – S A B C D 1 2 3 4 5 Vent sizes: 5 Vent lengths are available. inch (mm) S Vent suits walls 3 " 4 1/2 " (75 115) A Vent suits walls 4 1/2 " 9 1/2 " (115 240) B Vent suits.
– 50 – Flue Manifold P.C.B Combustion Fan Room Temperature Thermistor Over Heat Thermistor Solenoid Valve No.1 Modulating Valve Gas Inlet Solenoid Valve No.2 Injector Damper Main Burner Over Heat Switch(No.2) Warm Air Electrode Main Heat Exchanger Flame Rod Thermal Fuse Over Heat Switch (No.
– 51 – EXTENSION SET PARTS AND INSTALLATION GUIDE FOT 155 20"(0.5m) EXTENSION SET FOT 156 40"(1m) EXTENSION SET FOT 157 80"(2m) EXTENSION SET FOT 158 BENT ELBOW SET • This extension set is to be used for installations requiring extra distance.
– 52 – ■ TYPES COMP A TIBLE WITH EXTENSION SET RHFE-431FA INSTALLING AN EXTENSION KIT Installing an extension kit requires construction of an air line and the exhaust line. The air line is connected between the Air Supply Elbow at the rear of the heater and the air inlet port on the Flue pipe.
– 53 – 1. How to connect exhaust pipes 2. How to connect air intake hose To connect the exhaust pipes, fit the male end into the female end and clamp with pipe stopper A to prevent slipping. The exhaust pipe can be telescoped to the required length; do not cut it.
– 54 – ■ CAUTIONS 1. Maximum extendable length FOR BEST ROOM AIR HUMIDITY, KEEP WATER IN THE HUMIDIFIER TRAY. ・ 13 feet, 2 bends ・ The bend where the hose and pipes leave the body is not counted. ・ The air intake hose should run along the exhaust pipe.
– 55 – 4. Wherever the air intake hose and exhaust pipe run sideways, try to have the exhaust pipe on top (to prevent the air intake hose from sagging onto the exhaust pipe).
– 56 – TECHNICAL DA T A Burner Orifices: RHFE-431FA -P use: Orifice part #AU129-210 × 02-0.85(0.033") RHFE-431FA -N use: Orifice part #AU129-210 × 02-1.13(0.044") GAS CONVERSION SPECIFICATIONS GAS PRESSURE SETTING PROCEDURE WEIGHT DIMENSIONS GAS RATE (BTU/h) 51 Lbs.
.
– 58 – 431F-1700 × 17(00) Printed in Japan 2008.09 1 0 3 International Drive, Peachtree City, Georgia 3 0 2 6 9 Phone: 1 - 8 0 0-6 2 1-9 4 1 9 Fax: 1-8 8 8-4 7 4-6 6 2 4 www.rinnai.us Register your product at www .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Rinnai RHFE-431FA c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Rinnai RHFE-431FA - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Rinnai RHFE-431FA, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Rinnai RHFE-431FA va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Rinnai RHFE-431FA, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Rinnai RHFE-431FA.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Rinnai RHFE-431FA. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Rinnai RHFE-431FA ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.