Manuel d'utilisation / d'entretien du produit VPAP IV du fabricant ResMed
Aller à la page of 23
VP AP™ IV VP AP™ IV S T Positive Airw A y Pressure device User Guide English.
VP AP™ IV VP AP™ IV S T POSITIVE AI RWA Y PRESSURE DEVICE User Guide English ResMed Ltd (Manufacturer) 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia ResMed Corp (US Designated Agent) .
Cont ents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Contraindications 1 Adv erse Ef f ects 1 The VP AP S ystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 Introduction English Introduction The VPAP TM IV and the VPAP TM IV ST are intended to prov ide non-invasive ve ntilation for patients with respiratory insuffi ciency or obstructive sleep apnoea (OSA), in the hospital or home.
2 Masks The following Re sMed mask systems are re commended for use with these devices: For information on using masks, see your mask manual. For the latest avai lable masks, see www.resmed.com. Humidifier If you are experie ncing dryness of the nose, throat or mouth, the H4i heated humidifier is recommend ed for use with these VPAP devices.
3 Using the VP AP IV and VP AP IV ST English Using the VPAP IV and VPAP IV ST Setting up your VPAP 1 Connect the power cord to the sock et at the rear of your VPAP. 2 Plug the other end of the power co rd into the power outlet. 3 Connect one end of the air tubin g firmly onto the air outlet.
4 Attaching a H4i Humidifier The H4i humidifier atta ches to the front of a VPAP IV o r V PAP I V ST device to provide heated humidificati on. These devices automatic ally detect the presence of the H4i and no other accessories are required for its use.
5 Using the VP AP IV and VP AP IV ST English Using the Menus The VPAP IV and VP AP IV ST provide a se t of functions which are arrang ed in menus and submenus. Via the LCD screen, the menus and subme nus allow you to view and change the settings for a particular function.
6 How to Select the Mask Type Scroll to MASK and select . Press or until you see the setting you require. The following table shows the setti ng that should be selected for each mask: SmartStart™ If.
7 Using the VP AP IV and VP AP IV ST English 6 After starting therapy, an introductory treatment scre en will display: Stopping Treatment To stop treatment at any time, remove your mask and press . If your clinician has enabled SmartStart/Stop, simply remove your mask and treatment will end.
8 Reminders on the VPAP LCD Your clinician may have set your VPAP devi ce to remind yo u about important events, such as when to replace your mask, when to insert your Data Card (if your device is Data Card enabled ) and so on. The reminder message is display ed on the LCD and is visible if the device is not delivering therapy.
9 Using the VP AP IV and VP AP IV ST English Using the Data Card If your clinician need s to review your treatment, they will a sk you to use the Data Card to copy data from your VPAP device and return th e card to them. Copying Data onto a Data Card 1 Switch on your VPAP and wai t until you see the standby (Ramp) scree n.
10 Traveling with the VPAP IV and VP AP IV ST International Use Your VPAP flow generator has an internal pow er adapter that enable s it to operate in other countries. It will operate on power supplies of 100–240V and 50–60Hz. No special adjustment i s necessary, but you wil l require an approved power co rd for that country.
11 Cleaning and Maintenance English Cleaning and Maintenance You should regularly carry out the cleaning and main tenance described in this section. Refer to your mask and humidifier manuals fo r detailed instru ctions regarding the care of those devices.
12 Servicing This device is intended to pr ovide safe and reliable operati on when operated and maintained in accordance wi th the instructions provided by ResMed.
13 T roubleshooting English Troubleshooting If there is a p roblem, try the fol lowing suggestions. If the problem cannot be solved , contact your equipment supplier or Re sMed.
14 Displays er ror message: Exxxx Call Service (wher e xxxx defines an err or) Displays er ror message: HIGH LEAK!!! Adjust Mask The follow ing message is display ed on the LCD aft er you try to updat.
15 T echnical Specifications English Technical Specifications Note: • The manuf acturer reserves the right to c hange these specifications wi thout notice.
16 General Warnings and Cautions ! Warnings • Advice contained in this manual sh ould not supersede instructions given by the prescribing phy sician. • A patient should not connect a device to the data communication por t unless instructed to do so by their health care provider or physician.
17 General W arnings and Cautions English Guidance and Manufactur er’ s Declaration – Electromagnetic Emissi ons and Immunity Guidance and manufact urer’ s declaration – electromagnetic emissions The VP AP IV and VP AP IV ST devic es are intended f or use in t he electromagnet ic envir onment specifie d below .
18 Guidance and manu f acturer’ s de claration – electromagnetic immunity The VP AP device is intended f or use in the electromagn etic envi ronment specif ied belo w . T he customer or th e user of th e VP AP devic e should assur e that the de vice is used in suc h an en vironment.
19 Limited W arranty English Limited Warranty ResMed warrants that your ResMed product shall be free from defects in material and workmanship for the period speci fied below from the d ate of purchase by the initial co nsumer. Th is wa rranty is not transf erable.
20.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté ResMed VPAP IV c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du ResMed VPAP IV - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation ResMed VPAP IV, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le ResMed VPAP IV va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le ResMed VPAP IV, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du ResMed VPAP IV.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le ResMed VPAP IV. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei ResMed VPAP IV ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.