H8S/2338 Series QFP-144 User System Interface Cable (HS2338ECH61H) for E6000 Emulator User’s Manual HS2338ECH61HE(D).
Cautions 1. Renesas neither warrants nor grants li censes of any rights of Renesas’s or any t hird party’s patent, copyright, t rademark, or other intel lect ual property rights for informat ion contained in this document.
i Preface Thank you for purchasing this user system interface cable (HS2338ECH61H) for the Renesas’s original mi crocomputer H8S/2338 series. The HS2338ECH61H is a user system interface cable that c.
ii Contents Section 1 Configuration ................................................................................... 1 Section 2 Connection Procedures .................................................................... 4 2.1 Connecting User System Interf ace Cable to Em ulat or Station .
Section 1 Configuration 1 UTION CA Use an NQPACK144SD socket (manufactured by Tokyo Eletech Coporation) for the FP-144 package IC socket on the user system. Figure 1 shows the configuration of the HS2338E CH61H user system interface cable for the FP-144 package.
To emulator station Cable body Screws (M2 x 6 mm) Socket cover User system IC socket Cable head Screws (M2 x 10 mm) (for fastening cable head) Figure 1 HS2338ECH61H User System Interface Cable 2.
3 Table 1 lists t he HS2338ECH61H components. Please m ake sure you have all of these com ponents when unpacking. Table 1 HS2338ECH61H Components No. Component Quantity Remarks 1 Cable body 1 Includes.
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned.
Emulator station E6000 Cable body User system interface cable Figure 2 Connecting User System Interf ace Cable to Emulator Station 2.2 Connecting User System Interface Cable to User System W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part.
2.2.1 Installing IC Socket 1. Confirming t he location of IC socket 6 UTION CA After confirming the location of pin 1 on the IC socket, apply epoxy resin adhesive to the end of the four projections at the bottom of the IC socket, and fasten it to the user system.
2.2.2 Inserting Cable Head 7 UTION CA Check the location of pin 1 before inserting. Align pin 1 on the IC socket for a FP-144 system interface cable head into the IC socket on the user system, as shown in fi gure 4. 2.2.3 Fastening Cable Head CA UTION 1.
Fasten the user system interface cable head to the IC socket for an FP-144 package on the user system with the four screws (M2 x 10 m m) provided. Each screw should be tightened a little at a time, alternating between screws on opposi ng corners.
2.2.4 Connecting Cable Body to Cabl e Head Connect the cable body to the cable head. Cable body Cable head Remove jig Push the remove jig Removing User system Figure 5 Fastening Cable Body 9.
2.3 Recommended Dimensions for User System Mount Pad Figure 6 shows t he recomm ended dim ensions for the mount pad (footprint) for the user system with an IC socket for an FP-144 package (NQPACK144SD: m anufactured by Tokyo Eletech Corporation).
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interf ace cable head are shown in figure 7. Unit: mm Tolerance: –0.
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after conn ecting the user system interface cab le head to the user system, are shown in figure 8.
Section 3 Installing the MCU to the User System 13 UTION CA 1. Check the location of pin 1 before inserting. 2. Use the screwdriver provided for tightening screws.
MCU Pin 1 IC socket (NQPACK144SD manufactured by Tokyo Eleteck Corporation) User system Screws (M2 x 6 mm) Socket cover Figure 9 Installing MCU to User System 14.
Section 4 Verifying Operation 1. When using the E6000 emulator for the H8S/2338 series, turn on the emulator according to the procedures described in the E6000 Series Em ulator User's Ma nual (HS2000EPI61HE).
16 4. In the H8S/2338 series MCU, the interrupt signal pins can be selected by the register setting. To trace the interrupt signals in the E6000 emulator, se lect the interrupt signa l pins by setting switch P5 on the user system interface cable as shown in table 2.
Section 5 Notice 1. Make sure that pin 1 on the user syst em IC socket is correct ly aligned with pin 1 on t he cable head before inserting the cable head into the user system IC socket. 2. The dimensi ons of the recommended m ount pad for the user system IC socket are different from those of the MCU.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Renesas QFP-144 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Renesas QFP-144 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Renesas QFP-144, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Renesas QFP-144 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Renesas QFP-144, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Renesas QFP-144.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Renesas QFP-144. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Renesas QFP-144 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.